CoChat

Identifying Obstructive Sleep Apnea in Administrative Data: A Study of Diagnostic Accuracy

Open access
McIsaac, Daniel I., Gershon, Andrea, Wijeysundera, Duminda, Bryson, Gregory L., Badner, Neal, van Walraven, Carl · 2015 · Anesthesiology
Cited by 91

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

AbstractAbstract: In approximately 5,000 patients who underwent preoperative polysomnography, 56% met criteria for a diagnosis of obstructive sleep apnea (OSA). In these patients with known or excluded OSA, none of the health administrative diagnostic codes, diagnostic procedures, or therapeutic interventions by themselves or in combination identified OSA with adequately high sensitivity and specificity. Existing studies using administrative codes to identify OSA should be interpreted with caution. Background: Health administrative (HA) databases are increasingly used to identify surgical patients with obstructive sleep apnea (OSA) for research purposes, primarily using diagnostic codes. Such means to identify patients with OSA are not validated. The authors determined the accuracy of case-ascertainment algorithms for identifying patients with OSA with the use of HA data. Methods: Clinical data derived from an academic health sciences network within a universal health insurance plan were used as the reference standard. The authors linked patients to HA data and retrieved all claims in the 2 yr before surgery to determine the presence of any diagnostic codes, diagnostic procedures, or therapeutic interventions consistent with OSA. Results: The authors identified 4,965 patients (2003 to 2012) who underwent preoperative polysomnogram. Of these, 4,353 patients were linked to HA data; 2,427 of these (56%) had OSA based on diagnosis by a sleep physician or the apnea hypopnea index. A claim for a polysomnogram and receipt of a positive airway pressure device had a sensitivity, specificity, and positive likelihood ratio (+LR) for OSA of 19, 98, and 10.9%, respectively. An International Classification of Diseases, Tenth Revision , code for sleep apnea in hospitalization abstracts was 9% sensitive and 98% specific (+LR, 4.5). A physician billing claim for OSA ( International Classification of Diseases, Ninth Revision , 780.5) was 58% sensitive and 38% specific (+LR, 0.9). A polysomnogram and a positive airway pressure device or any code for OSA was 70% sensitive and 36% specific (+LR, 1.1). Conclusions: No code or combination of codes provided a +LR high enough to adequately identify patients with OSA. Existing studies using administrative codes to identify OSA should be interpreted with caution.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aln.0000000000000692

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 91

Metadata

Authors
McIsaac, D. I., Gershon, A., Wijeysundera, D., Bryson, G. L., Badner, N., & van Walraven, C.
Venue
Anesthesiology
Published
2015-08
Volume
123
Issue
2
Pages
253-263
ISSN
0003-3022 (ISSN-L)
OpenAlex
W1918109950
Cited by
91
References
12
FWCI
7.96
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Identifying Obstructive Sleep Apnea in Administrative Data: A Study of Diagnostic Accuracy. https://app.cochat.ai/papers/10.1097/aln.0000000000000692
The paper
McIsaac, D. I., Gershon, A., Wijeysundera, D., Bryson, G. L., Badner, N., & van Walraven, C. (2015). Identifying Obstructive Sleep Apnea in Administrative Data: A Study of Diagnostic Accuracy. Anesthesiology. https://doi.org/10.1097/aln.0000000000000692

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.