Surgical and Patient Risk Factors for Severe Arterial Line Complications in Adults
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
AbstractAbstract: In a series of 57,787 patients receiving arterial cannulation, 21 patients were identified as having experienced vascular complications or nerve injuries, resulting in a very low complication rate of 3.4/10,000. The rate of complications differed significantly (P < 0.001) across the three most common catheter sizes (2.7/10,000 for 20 gauge, 17.2/10,000 for 18 gauge, and 9.4/10,000 for 5 French). Given the low frequency of complications observed, the current study does not have sufficient statistical power to make definitive conclusions regarding the risk factors (listed in the appendix). Background: Prior research has provided inconsistent data regarding the risk factors associated with complications from arterial cannulation. The goal of this study was to clearly define the incidence and risks factors associated with arterial cannulation complications. Methods: After obtaining institutional review board approval, all patients requiring arterial line placement with documentation were included in this retrospective study between January 1, 2006, and December 31, 2012. Leveraging two robust data warehouses, the Perioperative DataMart and the Mayo Clinic Life Silences System, the authors cross-matched arterial line cannulation with a documented vascular consult, neurologic consult, infection, or return to surgery within 30 days in order to identify the initial patient population. Results: A total of 62,626 arterial lines were placed in 57,787 patients, and 90.1% of the catheters placed were 20-gauge catheters. The radial artery was cannulated in 94.5% of patients. A total of 21 patients were identified as having experienced vascular complications or nerve injuries, resulting in a complication rate of 3.4 per 10,000 (95% CI, 2.1 to 5.1). Cardiac surgery had the largest number of catheters placed (n = 15,419) with 12 complications (complication rate = 7.8 per 10,000; 95% CI, 4.0 to 13.6). The rate of complications differed significantly (P < 0.001) across the three most common catheter sizes (2.7 per 10,000 [95% CI, 1.5 to 4.4] for 20 gauge, 17.2 per 10,000 [95% CI, 4.7 to 43.9] for 18 gauge, and 9.4 per 10,000 [95% CI, 1.1 to 34.1] for 5 French). Conclusion: In a large retrospective study, the authors document a very low rate of complications with arterial line placement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jolly, S. S., Yusuf, S., Cairns, J., Niemelä, K., Xavier, D., Widimsky, P., Budaj, A., Niemelä, M., Valentin, V., Lewis, B. S., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)60404-2 · Cited by 2,125
Jolly, S. S., Amlani, S., Hamon, M., Yusuf, S., & Mehta, S. R. (2009) · American Heart Journal · doi:10.1016/j.ahj.2008.08.023 · Cited by 1,074
Scheer, B., Perel, A., & Pfeiffer, U. J. (2002) · Critical Care · doi:10.1186/cc1489 · Cited by 854
Problems due to Small Samples and Sparse Data in Conditional Logistic Regression Analysis
Greenland, S., Schwartzbaum, J. A., & Finkle, W. D. (2000) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a010240 · Cited by 370
On the Safety of Radial Artery Cannulation
Slogoff, S., Keats, A. S., & Arlund, C. (1983) · Anesthesiology · doi:10.1097/00000542-198307000-00008 · Cited by 355
Radial Artery Cannulation: A Comprehensive Review of Recent Anatomic and Physiologic Investigations
Brzezinski, M., Luisetti, T., & London, M. J. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181bbd416 · Cited by 354
Frezza, E. E., & Mezghebe, H. M. (1998) · PubMed · Cited by 206
Radial artery cannulation and ishaemic damage: a review
Wilkins, R. G. (1985) · Anaesthesia · doi:10.1111/j.1365-2044.1985.tb11055.x · Cited by 117
Catheterization of the radial or brachial artery in neonates and infants
SCHINDLER, E., KOWALD, B., SUESS, H., NIEHAUS‐BORQUEZ, B., TAUSCH, B., & BRECHER, A. (2005) · Pediatric Anesthesia · doi:10.1111/j.1460-9592.2004.01522.x · Cited by 111
Bayesian regression in SAS software
Sullivan, S. G., & Greenland, S. (2013) · International Journal of Epidemiology · doi:10.1093/ije/dys213 · Cited by 87
Cited by
How to measure blood pressure using an arterial catheter: a systematic 5-step approach
Saugel, B., Kouz, K., Meidert, A. S., Schulte-Uentrop, L., & Romagnoli, S. (2020) · Critical Care · doi:10.1186/s13054-020-02859-w · Cited by 214
Perioperative Blood Pressure Management
Saugel, B., & Sessler, D. I. (2021) · Anesthesiology · doi:10.1097/aln.0000000000003610 · Cited by 191
Saugel, B., Fletcher, N., Gan, T. J., Grocott, M. P. W., Myles, P. S., Sessler, D. I., Auzinger, G., Chappell, D., Gan, T. J., Edwards, M., et al. (2024) · British Journal of Anaesthesia · doi:10.1016/j.bja.2024.04.046 · Cited by 180
Clinical Study of Continuous Non-Invasive Blood Pressure Monitoring in Neonates
Rao, A., Eskandar-Afshari, F., Weiner, Y., Billman, E., McMillin, A., Sella, N., Roxlo, T., Liu, J., Leong, W., Helfenbein, E., et al. (2023) · Sensors · doi:10.3390/s23073690 · Cited by 14
“of gestational age as defined by the World Health Organization [1,4].”
Method
Metadata
- Authors
- Nuttall, G., Burckhardt, J., Hadley, A., Kane, S., Kor, D., Marienau, M. S., Schroeder, D. R., Handlogten, K., Wilson, G., & Oliver, W. C.
- Venue
- Anesthesiology
- Published
- 2016-03
- Volume
- 124
- Issue
- 3
- Pages
- 590-597
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2193633529
- Cited by
- 162
- References
- 12
- FWCI
- 5.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Surgical and Patient Risk Factors for Severe Arterial Line Complications in Adults. https://app.cochat.ai/papers/10.1097/aln.0000000000000967
- The paper
- Nuttall, G., Burckhardt, J., Hadley, A., Kane, S., Kor, D., Marienau, M. S., Schroeder, D. R., Handlogten, K., Wilson, G., & Oliver, W. C. (2016). Surgical and Patient Risk Factors for Severe Arterial Line Complications in Adults. Anesthesiology. https://doi.org/10.1097/aln.0000000000000967
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.