Catheterization of the radial or brachial artery in neonates and infants
The DOI matches its Crossref record.
Abstract
Summary: Background : In neonates and small children, percutaneous insertion of arterial catheters may be very difficult because of the small diameter of the arteries. Multiple attempts at cannulation are common and may be a predictor of serious adverse events following arterial cannulation. As an endartery, the brachial artery is usually not recommended for cannulation. However, limited data exist about brachial artery catheterization in neonates and young children. In this retrospective study, we report our experience with arterial indwelling catheters placed in neonates and small children prior to surgery for congenital heart defects. Methods : We reviewed 1473 patient medical files containing information about 1574 arterial lines for perioperative and intensive care monitoring. Patient data (age and weight), cannulation characteristics (site, type, percutaneous or cut down insertion), duration of catheterization and complications were documented using the anesthesia and/or intensive care unit files. Patients were divided into three groups according to body weight. Group I: patients with a bodyweight up to 5 kg (n = 561), group II: bodyweight 5–10 kg (n = 615), and group III: bodyweight 10–20 kg (n = 297). Results : The vast majority of our patients had radial or brachial artery catheterization. In group 1, we placed 200 brachial artery lines. Radial artery insertion was more successful with increasing body weight. Two ‘cut downs’ were necessary to place the arterial cannula (0.3%). The mean duration of the arterial cannula in place was 5.8 + 4.3 days in group I, which was significantly longer than in group III (2.9 + 2.2 days). Multiple attempts at catheter insertion were required for 200 patients in group I (P < 0.05 compared with groups II and III). The number of guide wires used was similar in all study groups. Generally, we preferred 24 and 22 G catheters for cannulation. Serious complications such as permanent ischemic damage were not observed. Temporary occlusion of an artery occurred in five of 1473 patients. The rate of local infection was 0.5% in group I, 0.7% in group II and 2.3% in group III. Local hematoma were observed more frequently, but with no relevant consequences. Most of our patients were cannulated on the right side. In group I, 112 brachial artery catheters were placed. The greater the weight, the more radial catheters were used compared with a brachial approach. The mean functional time of the catheters (5.8 ± 4.3 days in group I) was significant shorter compared with patients from group III (2.9 ± 2.2 days). In 33.3% (n = 200) multiple punctures were needed to place a catheter in group I (P < 0.05 compared with the other groups) whereas the use of a guide wire was evenly distributed throughout the study groups. Small catheters (24 and 22 G) were preferred for most patients. In total only eight 20 G sized catheters were used in the children of group III. Conclusions : Even considering the nature of a retrospective study design, we conclude that the brachial artery could be considered for cannulation in neonates and small children.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Radial Artery Cannulation: A Comprehensive Review of Recent Anatomic and Physiologic Investigations
Brzezinski, M., Luisetti, T., & London, M. J. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181bbd416 · Cited by 354
A Prospective Comparison of Ultrasound-guided and Blindly Placed Radial Arterial Catheters
Shiver, S., Blaivas, M., & Lyon, M. (2006) · Academic Emergency Medicine · doi:10.1197/j.aem.2006.07.015 · Cited by 173
“Studies in the pediatric anesthesia literature also confirm the utility of arterial guided cannulation in the stable peri-operative setting.(11,12) Our study, which used a 5–10 MHz linear transducer, revealed a statistically significant decrease in the time to successful arterial cannulation for the US-guided group co…”
BackgroundSurgical and Patient Risk Factors for Severe Arterial Line Complications in Adults
Nuttall, G., Burckhardt, J., Hadley, A., Kane, S., Kor, D., Marienau, M. S., Schroeder, D. R., Handlogten, K., Wilson, G., & Oliver, W. C. (2016) · Anesthesiology · doi:10.1097/aln.0000000000000967 · Cited by 162
Zhang, W., Li, K., Xu, H., Luo, D., Ji, C., Yang, K., & Zhao, Q. (2020) · Critical Care · doi:10.1186/s13054-020-02920-8 · Cited by 34
The ulnar artery: A site suitable for arterial cannulation in pediatric patients
Roux, J., Kohn, M. A., Sinskey, J., Nguyen, H., Boor, M., & Rouine‐Rapp, K. (2021) · Pediatric Anesthesia · doi:10.1111/pan.14311 · Cited by 5
Metadata
- Authors
- SCHINDLER, E., KOWALD, B., SUESS, H., NIEHAUS‐BORQUEZ, B., TAUSCH, B., & BRECHER, A.
- Venue
- Pediatric Anesthesia
- Publisher
- Wiley
- Published
- 2005-05-23
- Volume
- 15
- Issue
- 8
- Pages
- 677-682
- ISSN
- 1155-5645 (ISSN-L)
- 1460-9592
- OpenAlex
- W2122988418
- Cited by
- 111
- References
- 0
- FWCI
- 2.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Catheterization of the radial or brachial artery in neonates and infants. https://app.cochat.ai/papers/10.1111/j.1460-9592.2004.01522.x
- The paper
- SCHINDLER, E., KOWALD, B., SUESS, H., NIEHAUS‐BORQUEZ, B., TAUSCH, B., & BRECHER, A. (2005). Catheterization of the radial or brachial artery in neonates and infants. Pediatric Anesthesia. https://doi.org/10.1111/j.1460-9592.2004.01522.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.