CoChat

Approach Combining the Airway Scope and the Bougie for Minimizing Movement of the Cervical Spine during Endotracheal Intubation

Open access
Takenaka, Ichiro, Aoyama, Kazuyoshi, Iwagaki, Tamao, Ishimura, Hiroshi, Takenaka, Yukari, Kadoya, Tatsuo · 2009 · Anesthesiology
Cited by 52

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: The Airway Scope (AWS, AWS-S100; Hoya-Pentax, Tokyo, Japan), a recently introduced video laryngoscope, has been reported to reduce movement of the cervical spine during intubation attempts in comparison with conventional laryngoscopes. Use of the bougie as an aid for the AWS may cause further reduction. The authors compared cervical spine movement during intubation with the AWS with and without a bougie. Methods: Thirty patients without cervical spine abnormality were randomized into two groups: intubation with AWS only and intubation with the AWS and the bougie. The cervical spine motion between the occiput (C0) and the fourth cervical vertebra (C4) was observed fluoroscopically, and change in movement between adjacent vertebrae created by each intubation method was compared. Time to intubation was also measured. Results: Laryngoscopy with the AWS produced extension of the cervical spine segments assessed (C0-4). Median extension angle of the C0-4 during intubation using the AWS was reduced from 16.0 degrees without the bougie to 6.5 degrees with the bougie (P < 0.01). There was no significant difference in time to intubation between them. Conclusions: Use of the bougie resulted in significantly reduced extension of the cervical spine during intubation attempt with the AWS in patients with a normal cervical spine.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aln.0b013e31819fb44a

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 52

Metadata

Authors
Takenaka, I., Aoyama, K., Iwagaki, T., Ishimura, H., Takenaka, Y., & Kadoya, T.
Venue
Anesthesiology
Published
2009-06-01
Volume
110
Issue
6
Pages
1335-1340
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2093147768
Cited by
52
References
1
FWCI
7.59
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Approach Combining the Airway Scope and the Bougie for Minimizing Movement of the Cervical Spine during Endotracheal Intubation. https://app.cochat.ai/papers/10.1097/aln.0b013e31819fb44a
The paper
Takenaka, I., Aoyama, K., Iwagaki, T., Ishimura, H., Takenaka, Y., & Kadoya, T. (2009). Approach Combining the Airway Scope and the Bougie for Minimizing Movement of the Cervical Spine during Endotracheal Intubation. Anesthesiology. https://doi.org/10.1097/aln.0b013e31819fb44a

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.