Crossover Comparison of the Laryngeal Mask Supreme™ and the i-gel™ in Simulated Difficult Airway Scenario in Anesthetized Patients
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Background: The single-use supraglottic airway devices LMA-Supreme (LMA-S; Laryngeal Mask Company, Henley-on-Thames, United Kingdom) and i-gel (Intersurgical Ltd, Wokingham, Berkshire, United Kingdom) have a second tube for gastric tube insertion. Only the LMA-S has an inflatable cuff. They have the same clinical indications and might be useful for difficult airway management. This prospective, crossover, randomized controlled trial was performed in a simulated difficult airway scenario using an extrication collar limiting mouth opening and neck movement. Methods: Sixty patients were included. Both devices were placed in random order in each patient. Primary outcome was overall success rate. Other measurements were time to successful ventilation, airway leak pressure, fiberoptic glottic view, and adverse events. Results: Success rate for the LMA-S was 95% versus 93% for the i-gel (P = 1.000). LMA-S needed shorter insertion time (34 +/- 12 s vs. 42 +/- 23 s, P = 0.024). Tidal volumes and airway leak pressure were similar (LMA-S 26 +/- 8 cm H20; i-gel 27 +/- 9 cm H20; P = 0.441). Fiberoptic view through the i-gel showed less epiglottic downfolding. Overall agreement in insertion outcome was 54 (successes) and 1 (failure) or 55 (92%) of 60 patients. The difference in success rate was 1.7% (95% CI -11.3% to 7.6%). Conclusions: Both airway devices had similar insertion success and clinical performance in the simulated difficult airway situation. The authors found less epiglottic downfolding and better fiberoptic view but longer insertion time with the i-gel. Our study shows that both devices are feasible for emergency airway management in patients with reduced neck movement and limited mouth opening.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deakin, C. D., Nolan, J. P., Soar, J., Sunde, K., Koster, R. W., Smith, G. B., & Perkins, G. D. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.08.017 · Cited by 2,700
Difficult Airway Society guidelines for management of the unanticipated difficult intubation
Henderson, J. J., Popat, M. T., Latto, I. P., & Pearce, A. C. (2004) · Anaesthesia · doi:10.1111/j.1365-2044.2004.03831.x · Cited by 1,025 · cited 1×
“Both single-use devices, as other supraglottic airway management devices could have their value as backup devices in difficult airway management strategies, especially in the “cannot intubate, cannot ventilate” situation.(15,16) The i-gel has already been used in this setting.”
BackgroundEuropean Resuscitation Council Guidelines for Resuscitation 2005
Nolan, J. P., Deakin, C. D., Soar, J., Böttiger, B. W., & Smith, G. (2005) · Resuscitation · doi:10.1016/j.resuscitation.2005.10.009 · Cited by 834
Design and Analysis of Cross-Over Trials
Jones, B., & Kenward, M. G. (2003) · Chapman & Hall/CRC eBooks · doi:10.1201/9781420036091 · Cited by 484
The LMA ‘ProSeal’—a laryngeal mask with an oesophageal vent
Brain, A. I. J., Verghese, C., & Strube, P. J. (2000) · British Journal of Anaesthesia · doi:10.1093/bja/84.5.650 · Cited by 461
Arné, J., Descoins, P., Fusciardi, J., Ingrand, P., Ferrier, B., Boudigues, D., & Ariès, J. (1998) · British Journal of Anaesthesia · doi:10.1093/bja/80.2.140 · Cited by 401 · cited 1×
“Two patient characteristics among others predict difficult airway management: reduced neck extension and reduced mouth opening.(17) Limited mouth opening may even be a reason why supraglottic airway devices fail.”
BackgroundLevitan, R. M., & Kinkle, W. C. (2005) · Anaesthesia · doi:10.1111/j.1365-2044.2005.04258.x · Cited by 235
The intubating laryngeal mask airway: an initial assessment of performance
Kapila, A., Addy, E. V., Verghese, C., & Brain, A. I. J. (1997) · British Journal of Anaesthesia · doi:10.1093/bja/79.6.710 · Cited by 180
Brimacombe, J. R., KELLER, C., & Judd, D. V. (2003) · Anesthesiology · doi:10.1097/00000542-200401000-00008 · Cited by 177
Cited by
Frerk, C., Mitchell, V. S., McNarry, A. F., Mendonca, C., Bhagrath, R., Patel, A., O’Sullivan, E. P., Woodall, N. M., & Ahmad, I. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev371 · Cited by 2,214
European Resuscitation Council Guidelines for Resuscitation 2015
Perkins, G. D., Handley, A. J., Koster, R. W., Castrén, M., Smyth, M. A., Olasveengen, T., Monsieurs, K. G., Raffay, V., Gräsner, J.-T., Wenzel, V., et al. (2015) · Resuscitation · doi:10.1016/j.resuscitation.2015.07.015 · Cited by 1,287
Self-citationGuidelines for the management of tracheal intubation in critically ill adults
Higgs, A., McGrath, B. A., Goddard, C., Rangasami, J., Suntharalingam, G., Gale, R., & Cook, T. M. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2017.10.021 · Cited by 900
European Resuscitation Council Guidelines for Resuscitation 2015
Maconochie, I. K., Bingham, R., Eich, C., López-Herce, J., Rodríguez-Núñez, A., Rajka, T., Van de Voorde, P., Zideman, D. A., Biarent, D., Monsieurs, K. G., et al. (2015) · Resuscitation · doi:10.1016/j.resuscitation.2015.07.028 · Cited by 450
Myatra, S. N., Shah, A., Kundra, P., Patwa, A., Ramkumar, V., Divatia, J. V., Raveendra, U. S., Shetty, S. R., Ahmed, S. M., Doctor, J. R., et al. (2016) · Indian Journal of Anaesthesia · doi:10.4103/0019-5049.195481 · Cited by 294
Kleine-Brueggeney, M., Greif, R., Schoettker, P., Savoldelli, G. L., Nabecker, S., & Theiler, L. G. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aew058 · Cited by 216
“percentile) [range]} 17 (12; 23) [6–46] 19 (14; 29) [3–100] 18 (13; 24) [6–53] 20 (12; 28) [5–110] 30 (21; 55) [9–142] 26 (16; 32) [7–117] <0.”
InfluentialSelf-citation
Metadata
- Authors
- Theiler, L. G., Kleine-Brueggeney, M., Kaiser, D., Urwyler, N., Luyet, C., Vogt, A., Greif, R., & Unibe, M. M. E.
- Venue
- Anesthesiology
- Published
- 2009-07-01
- Volume
- 111
- Issue
- 1
- Pages
- 55-62
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1992790484
- Cited by
- 167
- References
- 15
- FWCI
- 17.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.