Ultrasound Assessment of Gastric Content and Volume
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Background: Aspiration of gastric contents can be a serious perioperative complication, attributing up to 9% of all anesthesia-related deaths. However, there is currently no practical, noninvasive bedside test to determine gastric content and volume in the perioperative period. Methods: The current study evaluates the feasibility of using bedside ultrasonography for assessing gastric content and volume. In the pilot phase, 18 healthy volunteers were examined to assess the gastric antrum, body, and fundus in cross-section in five prandial states: fasting and after ingestion of 250 mL of water, 500 mL of water, 500 mL of effervescent water, and a solid meal. In the phase II study, the authors concentrated on ultrasound examination of the gastric antrum in 36 volunteers for whom regression analysis was used to determine the correlation between gastric volume and antral cross-sectional area. Results: The gastric antrum provided the most reliable quantitative information for gastric volume. The antral cross-sectional area correlated with volumes of up to 300 mL in a close-to-linear fashion, particularly when subjects were in the right lateral decubitus position. Sonographic assessment of the gastric antrum and body provides qualitative information about gastric content (empty or not empty) and its nature (gas, fluid, or solid). The fundus was the gastric area least amenable to image and measure. Conclusions: Our preliminary results suggest that bedside two-dimensional ultrasonography can be a useful noninvasive tool to determine gastric content and volume.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2011) · Anesthesiology · doi:10.1097/aln.0b013e3181fcbfd9 · Cited by 1,217
Clinical Significance of Pulmonary Aspiration during the Perioperative Period
Warner, M. A., Warner, M. E., & Weber, J. G. (1993) · Anesthesiology · doi:10.1097/00000542-199301000-00010 · Cited by 808
Aspiration in severe trauma: a prospective study
Lockey, D. J., Coats, T., & Parr, M. J. A. (1999) · Anaesthesia · doi:10.1046/j.1365-2044.1999.00754.x · Cited by 514
Measurement of gastric emptying time by real-time ultrasonography
Bolondi, L., Bortolotti, M., Santi, V., Calletti, T., Gaiani, S., & Labò, G. (1985) · Gastroenterology · doi:10.1016/0016-5085(85)90569-4 · Cited by 461
Milling, T. J., Rose, J., Briggs, W. M., Birkhahn, R., Gaeta, T. J., Bove, J. J., & Melniker, L. A. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000171533.92856.e5 · Cited by 334
NARCOTIC ANALGESICS AND DELAYED GASTRIC EMPTYING DURING LABOUR
Nimmo, W. S., Wilson, J., & Prescott, L. F. (1975) · The Lancet · doi:10.1016/s0140-6736(75)91687-6 · Cited by 285
Real-Time Chest Ultrasonography
Beckh, S., Bo¨lcskei, P. L., & Lessnau, K.-D. (2002) · Chest · doi:10.1378/chest.122.5.1759 · Cited by 196
Gastric emptying in infants with or without gastro-oesophageal reflux according to the type of milk.
Billeaud, C., Guillet, J., & Sandler, B. (1990) · PubMed · Cited by 190
Eating in labour. A randomised controlled trial assessing the risks and benefits
Scrutton, M., Metcalfe, G. A., Lowy, C., Seed, P. T., & O’Sullivan, G. (1999) · Anaesthesia · doi:10.1046/j.1365-2044.1999.00750.x · Cited by 136
Näslund, E. (2000) · Scandinavian Journal of Gastroenterology · doi:10.1080/003655200750023930 · Cited by 110
Darwiche, G., Björgell, O., Thorsson, O., & Almér, L. (2003) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2003.22.5.459 · Cited by 95
INGESTION OF CLEAR FLUIDS IS SAFE FOR ADOLESCENTS UP TO 3 H BEFORE ANAESTHESIA
Splinter, W. M., & Schaefer, J. (1991) · British Journal of Anaesthesia · doi:10.1093/bja/66.1.48 · Cited by 72
Peripartum changes in gastric emptying
SANDHAR, B. K., ELLIOTT, R. H., WINDRAM, I., & Rowbotham, D. J. (1992) · Anaesthesia · doi:10.1111/j.1365-2044.1992.tb02116.x · Cited by 64
Cited by
Ultrasound assessment of gastric content and volume
Van de Putte, P., & Perlas, A. (2014) · British Journal of Anaesthesia · doi:10.1093/bja/aeu151 · Cited by 482
Self-citationPerlas, A., Mitsakakis, N., Liu, L., Cino, M., Haldipur, N., Davis, L., Cubillos, J., & Chan, V. (2013) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318274fc19 · Cited by 439
Self-citationBouvet, L., Mazoit, J.-X., Chassard, D., Allaouchiche, B., Boselli, E., & Benhamou, D. (2011) · Anesthesiology · doi:10.1097/aln.0b013e31820dee48 · Cited by 343
Gastric Sonography in the Fasted Surgical Patient: A Prospective Descriptive Study
Perlas, A., Davis, L., Khan, M., Mitsakakis, N., & Chan, V. W. S. (2011) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31821b98c0 · Cited by 330
Self-citationUltrasonography in the management of the airway
KRISTENSEN, M. S. (2011) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2011.02518.x · Cited by 230
Metadata
- Authors
- Perlas, A., Chan, V. W. S., Lupu, C. M., Mitsakakis, N., & Hanbidge, A.
- Venue
- Anesthesiology
- Published
- 2009-07-01
- Volume
- 111
- Issue
- 1
- Pages
- 82-89
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2074839866
- Cited by
- 451
- References
- 13
- FWCI
- 5.51
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.