CoChat

Prediction of Pediatric Endotracheal Tube Size by Ultrasonography

Open access
Shibasaki, Masayuki, Nakajima, Yasufumi, Ishii, Sachiyo, Shimizu, Fumihiro, Shime, Nobuaki, Sessler, Daniel I. · 2010 · Anesthesiology
Cited by 236

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Background: Formulas based on age and height often fail to reliably predict the proper endotracheal tube (ETT) size in pediatric patients. We, thus, tested the hypothesis that subglottic diameter, as determined by ultrasonography, better predicts optimal ETT size than existing methods. Methods: A total of 192 patients, aged 1 month to 6 yr, who were scheduled for surgery and undergoing general anesthesia were enrolled and divided into development and validation phases. In the development group, the optimal ETT size was selected according to standard age-based formulas for cuffed and uncuffed tubes. Tubes were replaced as necessary until a good clinical fit was obtained. Via ultrasonography, the subglottic upper airway diameter was determined before tracheal intubation. We constructed a regression equation between the subglottic upper airway diameter and the outer diameter of the ETT finally selected. In the validation group, ETT size was selected after ultrasonography using this regression equation. The primary outcome was the fraction of initial cuffed and uncuffed tube sizes, as selected through the regression formula, that proved clinically optimal. Results: Subglottic upper airway diameter was highly correlated with outer ETT diameter deemed optimal on clinical grounds. The rate of agreement between the predicted ETT size based on ultrasonic measurement and the final ETT size selected clinically was 98% for cuffed ETTs and 96% for uncuffed ETTs. Conclusions: Measuring subglottic airway diameter with ultrasonography facilitates the selection of appropriately sized ETTs in pediatric patients. This selection method better predicted optimal outer ETT diameter than standard age- and height-based formulas.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aln.0b013e3181ef6757

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 236

Metadata

Authors
Shibasaki, M., Nakajima, Y., Ishii, S., Shimizu, F., Shime, N., & Sessler, D. I.
Venue
Anesthesiology
Published
2010-10-01
Volume
113
Issue
4
Pages
819-824
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2019672635
Cited by
236
References
8
FWCI
6.12
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prediction of Pediatric Endotracheal Tube Size by Ultrasonography. https://app.cochat.ai/papers/10.1097/aln.0b013e3181ef6757
The paper
Shibasaki, M., Nakajima, Y., Ishii, S., Shimizu, F., Shime, N., & Sessler, D. I. (2010). Prediction of Pediatric Endotracheal Tube Size by Ultrasonography. Anesthesiology. https://doi.org/10.1097/aln.0b013e3181ef6757

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.