The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Preoperative Cerebral Oxygen Saturation and Clinical Outcomes in Cardiac Surgery
Open accessAbstract
Background: The current study was designed to determine the relation between preoperative cerebral oxygen saturation (Sco2), variables of cardiopulmonary function, mortality, and morbidity in a heterogeneous cohort of cardiac surgery patients. Methods: In this study, 1,178 consecutive patients scheduled for on-pump surgery were prospectively studied. Preoperative Sco2, demographics, N-terminal pro-B-type natriuretic peptide, high-sensitive troponin T, clinical outcomes, and 30-day and 1-yr mortality were recorded. Results: Median additive EuroSCORE was 5 (range: 0-19). Thirty-day and 1-yr mortality and major morbidity (at least two major complications and/or a high-dependency unit stay of at least 10 days) were 3.5%, 7.7%, and 13.3%, respectively. Median minimal preoperative oxygen supplemented Sco2 (Sco2min-ox) was 64% (range: 15-92%). Sco2min-ox was correlated (all: P value <0.0001) with N-terminal pro-B-type natriuretic peptide (ρ: -0.35), high-sensitive troponin T (ρ: -0.28), hematocrit (ρ: 0.34), glomerular filtration rate (ρ: 0.19), EuroSCORE (τ: 0.20), and left ventricular ejection fraction class (τ: 0.12). Thirty-day nonsurvivors had a lower Sco2min-ox than survivors (median 58% [95% CI, 50.7-62%] vs. 64% [95% CI, 64-65%]; P < 0.0001). Receiver-operating curve analysis of Sco2min-ox and 30-day mortality revealed an area-under-the-curve of 0.71 (95% CI, 0.68-0.73%; P < 0.0001) in the total cohort and an area-under-the-curve of 0.77 (95% CI, 0.69-0.86%; P < 0.0001) in patients with a EuroSCORE more than 10. Logistic regression based on different EuroSCORE categories (0-2; 3-5, 6-10, >10), Sco2min-ox, and duration of cardiopulmonary bypass showed that a Sco2min-ox equal or less than 50% is an independent risk factor for 30-day and 1-yr mortality. Conclusions: Preoperative Sco2 levels are reflective of the severity of cardiopulmonary dysfunction, associated with short- and long-term mortality and morbidity, and may add to preoperative risk stratification in patients undergoing cardiac surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Levey, A. S., Bosch, J. P., Lewis, J. B., Greene, T., Rogers, N., Roth, D., & for the Modification of Diet in Renal Disease Study Group* (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-6-199903160-00002 · Cited by 15,079
Cerebral Vascular Accidents in Patients over the Age of 60: II. Prognosis
Rankin, J. (1957) · Scottish Medical Journal · doi:10.1177/003693305700200504 · Cited by 2,506
Roques, F. (1999) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(99)00106-2 · Cited by 1,759
The Society of Thoracic Surgeons 2008 Cardiac Surgery Risk Models: Part 2—Isolated Valve Surgery
O'Brien, S. M., Shahian, D. M., Filardo, G., Ferraris, V. A., Haan, C. K., Rich, J. B., Normand, S.-L. T., DeLong, E. R., Shewan, C. M., Dokholyan, R. S., et al. (2009) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2009.05.056 · Cited by 1,259
Shahian, D. M., O'Brien, S. M., Filardo, G., Ferraris, V. A., Haan, C. K., Rich, J. B., Normand, S.-L. T., DeLong, E. R., Shewan, C. M., Dokholyan, R. S., et al. (2009) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2009.05.053 · Cited by 1,256
A Sensitive Cardiac Troponin T Assay in Stable Coronary Artery Disease
Omland, T., de Lemos, J. A., Sabatine, M. S., Christophi, C. A., Rice, M. M., Jablonski, K. A., Tjora, S., Domanski, M. J., Gersh, B. J., Rouleau, J. L., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0805299 · Cited by 901
Near-infrared spectroscopy as an index of brain and tissue oxygenation
Murkin, J. M., & Arango, M. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aep299 · Cited by 877
Monitoring Brain Oxygen Saturation During Coronary Bypass Surgery: A Randomized, Prospective Study
Murkin, J. M., Adams, S. J., Novick, R. J., Quantz, M., Bainbridge, D., Iglesias, I., Cleland, A., Schaefer, B., Irwin, B., & Fox, S. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000246814.29362.f4 · Cited by 813
Latini, R., Masson, S., Anand, I. S., Missov, E., Carlson, M., Vago, T., Angelici, L., Barlera, S., Parrinello, G., Maggioni, A. P., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.655076 · Cited by 709
Slater, J. P., Guarino, T., Stack, J., Vinod, K., Bustami, R. T., Brown, J. M., Rodriguez, A. L., Magovern, C. J., Zaubler, T., Freundlich, K., et al. (2009) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2008.08.070 · Cited by 626
Ranucci, M., Castelvecchio, S., Menicanti, L., Frigiola, A., & Pelissero, G. (2009) · Circulation · doi:10.1161/circulationaha.108.842393 · Cited by 400
Yao, F.-S. F., Tseng, C.-C. A., Ho, C.-Y. A., Levin, S. K., & Illner, P. (2004) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2004.07.007 · Cited by 351
Casati, A., Fanelli, G. C., Pietropaoli, P., Proietti, R., Tufano, R., Danelli, G. F., Fierro, G., COSMO, G. D., & Servillo, G. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000166974.96219.cd · Cited by 336
A Proposed Algorithm for the Intraoperative Use of Cerebral Near-Infrared Spectroscopy
Denault, A. Y., Deschamps, A., & Murkin, J. M. (2007) · Seminars in Cardiothoracic and Vascular Anesthesia · doi:10.1177/1089253207311685 · Cited by 329
Kim, M. B., Ward, D. S., Cartwright, C. R., Kolano, J., Chlebowski, S., & Henson, L. C. (2000) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009940031063 · Cited by 244
Near-Infrared Spectroscopy Cerebral Oxygen Saturation Thresholds for Hypoxia–Ischemia in Piglets
Kurth, C. D., Levy, W. J., & McCann, J. (2002) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200203000-00011 · Cited by 236
EuroSCORE: a systematic review of international performance
Gogbashian, A., Sedrakyan, A., & Treasure, T. (2004) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2004.02.022 · Cited by 213
Cerebral Oximetry for Cardiac and Vascular Surgery
Edmonds, H. L., Ganzel, B. L., & Austin, E. H. (2004) · Seminars in Cardiothoracic and Vascular Anesthesia · doi:10.1177/108925320400800208 · Cited by 203
Olsson, C., & Thelin, S. (2006) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2005.08.068 · Cited by 145
Nagdyman, N., Ewert, P., Peters, B., Miera, O., Fleck, T., & Berger, F. F. (2007) · Pediatric Anesthesia · doi:10.1111/j.1460-9592.2007.02365.x · Cited by 118
EuroSCORE Performance in Valve Surgery: A Meta-Analysis
Parolari, A., Pesce, L. L., Trezzi, M., Cavallotti, L., Kassem, S., Loardi, C. M., Pacini, D., Tremoli, E., & Alamanni, F. (2010) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2009.11.032 · Cited by 105
Recent Advances in Application of Cerebral Oximetry in Adult Cardiovascular Surgery
Fischer, G. W. (2008) · Seminars in Cardiothoracic and Vascular Anesthesia · doi:10.1177/1089253208316443 · Cited by 73
Well‐being and cerebral oxygen saturation during acute heart failure in humans
Madsen, Nielsen, & Christiansen (2000) · Clinical Physiology · doi:10.1046/j.1365-2281.2000.00241.x · Cited by 71
Cuthbertson, B. H., Croal, B. L., Rae, D., Gibson, P. H., McNeilly, J., Jeffrey, R. R., Smith, W. C. S., Prescott, G. J., Buchan, K., El-Shafei, H., et al. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aep234 · Cited by 67
Detection and Treatment of Cerebral Hypoxia Key to Avoiding Intraoperative Brain Injuries
Edmonds, H. L. (2000) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009976506571 · Cited by 33
Heringlake, M., Kox, T., Poeling, J., Klaus, S., Hanke, T., Franz, N., Eberhardt, F., Heinze, H., Armbruster, F., & Bahlmann, L. (2009) · European journal of medical research · doi:10.1186/2047-783x-14-3-106 · Cited by 15
Self-citation
Cited by
2011 ACCF/AHA Guideline for Coronary Artery Bypass Graft Surgery
Hillis, L. D., Smith, P. K., Anderson, J. L., Bittl, J. A., Bridges, C. R., Byrne, J. G., Cigarroa, J. E., DiSesa, V. J., Hiratzka, L. F., Hutter, A. M., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.009 · Cited by 820
Writing Committee Members, Hillis, L. D., Smith, P. K., Anderson, J. L., Bittl, J. A., Bridges, C. R., Byrne, J. G., Cigarroa, J. E., DiSesa, V. J., Hiratzka, L. F., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31823c074e · Cited by 781
Scheeren, T. W. L., Schober, P., & Schwarte, L. A. (2012) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-012-9348-y · Cited by 478
2019 EACTS Expert Consensus on long-term mechanical circulatory support
Potapov, E. V., Antonides, C., Crespo-Leiro, M. G., Combes, A., Färber, G., Hannan, M. M., Kukucka, M., de Jonge, N., Loforte, A., Lund, L. H., et al. (2019) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezz098 · Cited by 399
Davie, S. N., & Grocott, H. P. (2012) · Anesthesiology · doi:10.1097/aln.0b013e31824c00d7 · Cited by 383
Metadata
- Authors
- Heringlake, M., Garbers, C., Käbler, J.-H., Anderson, I., Heinze, H., Schön, J., Berger, K.-U., Dibbelt, L., Sievers, H.-H., & Hanke, T.
- Venue
- Anesthesiology
- Published
- 2011-01-01
- Volume
- 114
- Issue
- 1
- Pages
- 58-69
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2171124494
- Cited by
- 303
- References
- 26
- FWCI
- 22.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.