Invasive and Concomitant Noninvasive Intraoperative Blood Pressure Monitoring
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Background: Noninvasive (NIBP) and intraarterial (ABP) blood pressure monitoring are used under different circumstances and may yield different values. The authors endeavored to characterize these differences and hypothesized that there could be differences in interventions associated with the use of ABP alone ([ABP]) versus ABP in combination with NIBP ([ABP+NIBP]). Methods: Simultaneous measurements of ABP and NIBP made during noncardiac cases were extracted from electronic anesthesia records; the differences were subjected to regression analysis. Records of blood products, vasopressors, and antihypertensives administered were also extracted, and associations between the use of these therapies and monitoring strategy ([ABP] vs. [ABP+NIBP]) were tested using univariate, multivariate, and propensity score matched analyses. Results: Among 24,225 cases, 63% and 37% used [ABP+NIBP] and [ABP], respectively. Systolic NIBP was likely to be higher than ABP when ABP was less than 111 mmHg and lower than ABP otherwise. Among patients with hypotension, transfusion occurred in 27% versus 43% of patients in the [ABP+NIBP] versus [ABP] group, respectively (odds ratio = 0.4; 95% CI 0.35-0.46), and 7% versus 18% of patients in the [ABP+NIBP] versus [ABP] group received vasopressor infusions, respectively (P < 0.01). Among hypertensive patients, 12% versus 44% of those in the [ABP+NIBP] versus [ABP] group received antihypertensive agents, respectively (P < 0.01). Conclusions: NIBP was generally higher than ABP during periods of hypotension and lower than ABP during periods of hypertension. The use of NIBP measurements to supplement ABP measurements was associated with decreased use of blood transfusions, vasopressor infusions, and antihypertensive medications compared with the use of ABP alone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785 · cited 1×
“The concordance correlation coefficients between ABP and NIBP were also calculated.(4,5) Patients with more than 20 records (5 min cumulative) of systolic ABP less than 90 mmHg were considered hypotensive, and those with systolic ABP more than 140 mmHg were considered hypertensive.”
MethodPickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Sekhon, J. S. (2011) · Journal of Statistical Software · doi:10.18637/jss.v042.i07 · Cited by 1,543
Genetic Optimization Using Derivatives: The rgenoud Package for R
Mebane, W. R., & Sekhon, J. S. (2011) · Journal of Statistical Software · doi:10.18637/jss.v042.i11 · Cited by 638
An R2 statistic for fixed effects in the linear mixed model
Edwards, L. J., Muller, K. E., Wolfinger, R. D., Qaqish, B. F., & Schabenberger, O. (2008) · Statistics in Medicine · doi:10.1002/sim.3429 · Cited by 627 · cited 1×
“The R(2) statistic for the linear mixed model was calculated to estimate the proportion of variation in responses explained by the two predictors after accounting for the covariance of the repeated measurements.(3) The concordance correlation coefficients between ABP and NIBP were also calculated.”
MethodAvolio, A. P., Van Bortel, L. M., Boutouyrie, P., Cockcroft, J. R., McEniery, C. M., Protogerou, A. D., Roman, M. J., Safar, M. E., Segers, P., & Smulyan, H. (2009) · Hypertension · doi:10.1161/hypertensionaha.109.134379 · Cited by 521
Assay Validation Using the Concordance Correlation Coefficient
Lin, L. I.-K. (1992) · Biometrics · doi:10.2307/2532314 · Cited by 419 · cited 1×
“The concordance correlation coefficients between ABP and NIBP were also calculated.(4,5) Patients with more than 20 records (5 min cumulative) of systolic ABP less than 90 mmHg were considered hypotensive, and those with systolic ABP more than 140 mmHg were considered hypertensive.”
MethodDorman, T., Breslow, M. J., Lipsett, P. A., Rosenberg, J. M., Balser, J. R., Almog, Y., & Rosenfeld, B. A. (1998) · Critical Care Medicine · doi:10.1097/00003246-199810000-00014 · Cited by 189
INVASIVE V. NON-INVASIVE MEASUREMENT OF ARTERIAL PRESSURE
van Egmond, J., Hasenbos, M. A. W. M., & Crul, J. F. (1985) · British Journal of Anaesthesia · doi:10.1093/bja/57.4.434 · Cited by 129 · cited 1×
“Still, some investigators have suggested that ABP and NIBP are interchangeable, particularly for mean pressures.(17,18) One study similar to ours compared the two monitoring modalities during induced hypotension using volatile anesthetics in a small number of patients.”
ResultMignini, M. A., Piacentini, E. A., & Dubín, A. (2006) · Critical Care · doi:10.1186/cc4852 · Cited by 89 · cited 1×
“Still, some investigators have suggested that ABP and NIBP are interchangeable, particularly for mean pressures.(17,18) One study similar to ours compared the two monitoring modalities during induced hypotension using volatile anesthetics in a small number of patients.”
ResultRadial to femoral arterial blood pressure differences during liver transplantation
Velasco, D. A., Garutti, I., Pérez-Peña, J. M., Olmedilla, L., & Tzenkov, I. G. (2005) · Anaesthesia · doi:10.1111/j.1365-2044.2005.04257.x · Cited by 67
Why an Alternative to Blood Transfusion?
Shander, A., & Goodnough, L. T. (2009) · Critical Care Clinics · doi:10.1016/j.ccc.2008.12.012 · Cited by 56
A comparison of radial, brachial, and aortic pressures after cardiopulmonary bypass
Gravlee, G. P., Wong, A. B., Adkins, T. G., Case, L. D., & Pauca, A. L. (1989) · Journal of Cardiothoracic Anesthesia · doi:10.1016/0888-6296(89)90006-9 · Cited by 53
Femoral–radial arterial pressure gradients in critically ill patients
Galluccio, S. T., Chapman, M. J., & Finnis, M. (2009) · Critical Care and Resuscitation · doi:10.1016/s1441-2772(23)01830-6 · Cited by 49
Should we target blood pressure in sepsis?
Takala, J. A. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181f2430c · Cited by 42
Oscillometry and direct blood pressure: A comparative clinical study during deliberate hypotension
Gourdeau, M., Martin, R., Lamarche, Y., & Tétreault, L. (1986) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03010741 · Cited by 38 · cited 1×
“One study similar to ours compared the two monitoring modalities during induced hypotension using volatile anesthetics in a small number of patients.(19) The authors reported the crossover between “overestimation” and “underestimation” of ABP by NIBP at approximately 80 mmHg, which is lower than the crossover seen in…”
ResultReliability of the Radial Arterial Pressure During Anesthesia
Pauca, A. L., Wallenhaupt, S. L., & Kon, N. D. (1994) · CHEST Journal · doi:10.1378/chest.105.1.69 · Cited by 24
Cited by
Mancia, G., Kreutz, R., Brunström, M., Burnier, M., Grassi, G., Januszewicz, A., Muiesan, M. L., Tsioufis, K., Agabiti-Rosei, E., Algharably, E. A. E., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003480 · Cited by 3,473
Noninvasive Continuous Arterial Blood Pressure Monitoring with Nexfin®
Martina, J. R., Westerhof, B. E., van Goudoever, J., de Beaumont, E. M. F. H., Truijen, J., Kim, Y.-S., Immink, R. V., Jöbsis, D. A., Hollmann, M. W., Lahpor, J. R., et al. (2012) · Anesthesiology · doi:10.1097/aln.0b013e31824f94ed · Cited by 292
Wang, Z., Wang, S., Zeng, J., Ren, X., Chee, A. J. Y., Yiu, B. Y. S., Chung, W. C., Yang, Y., Yu, A. C. H., Roberts, R. C., et al. (2016) · Small · doi:10.1002/smll.201601419 · Cited by 244
How to measure blood pressure using an arterial catheter: a systematic 5-step approach
Saugel, B., Kouz, K., Meidert, A. S., Schulte-Uentrop, L., & Romagnoli, S. (2020) · Critical Care · doi:10.1186/s13054-020-02859-w · Cited by 214
Saugel, B., Fletcher, N., Gan, T. J., Grocott, M. P. W., Myles, P. S., Sessler, D. I., Auzinger, G., Chappell, D., Gan, T. J., Edwards, M., et al. (2024) · British Journal of Anaesthesia · doi:10.1016/j.bja.2024.04.046 · Cited by 180
“68 A consequence is that hypotensive harm thresholds for organ injury could differ with each arterial pressure measurement technique.”
Metadata
- Authors
- Wax, D. B., Lin, H.-M., & Leibowitz, A. B.
- Venue
- Anesthesiology
- Published
- 2011-11-01
- Volume
- 115
- Issue
- 5
- Pages
- 973-978
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1991652362
- Cited by
- 178
- References
- 17
- FWCI
- 6.33
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.