Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 352

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Comparative Effectiveness of the C-MAC Video Laryngoscope versus Direct Laryngoscopy in the Setting of the Predicted Difficult Airway

Open access
Aziz, Michael F., Dillman, Dawn, Fu, Rongwei, Brambrink, Ansgar M.·2012·Anesthesiology

Abstract

Background: Video laryngoscopy may be useful in the setting of the difficult airway, but it remains unclear if intubation success is improved in routine difficult airway management. This study compared success rates for tracheal intubation with the C-MAC® video laryngoscope (Karl Storz, Tuttlingen, Germany) with conventional direct laryngoscopy in patients with predicted difficult airway. Methods: We conducted a two arm, single-blinded randomized controlled trial that involved 300 patients. Inclusion required at least one of four predictors of difficult intubation. The primary outcome was successful tracheal intubation on first attempt. Results: The use of video laryngoscopy resulted in more successful intubations on first attempt (138/149; 93%) as compared with direct laryngoscopy (124/147; 84%), P = 0.026. Cormack-Lehane laryngeal view was graded I or II in 139/149 of C-MAC attempts versus 119/147 in direct laryngoscopy attempts (P < 0.01). Laryngoscopy time averaged 46 s (95% CI, 40-51) for the C-MAC group and was shorter in the direct laryngoscopy group, 33 s (95% CI, 29-36), P < 0.001. The use of a gum-elastic bougie and/or external laryngeal manipulation were required less often in the C-MAC intubations (24%, 33/138) compared with direct laryngoscopy (37%, 46/124, P = 0.020). The incidence of complications was not significantly different between the C-MAC (20%, 27/138) versus direct laryngoscopy (13%, 16/124, P = 0.146). Conclusion: A diverse group of anesthesia providers achieved a higher intubation success rate on first attempt with the C-MAC in a broad range of patients with predictors of difficult intubation. C-MAC laryngoscopy seems to be a useful technique for the initial approach to a potentially difficult airway.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aln.0b013e318246ea34

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 352

Metadata

Authors
Aziz, M. F., Dillman, D., Fu, R., & Brambrink, A. M.
Venue
Anesthesiology
Published
2012-03-01
Volume
116
Issue
3
Pages
629-636
ISSN
0003-3022 (ISSN-L)
OpenAlex
W1965115380
Cited by
352
References
24
FWCI
38.77
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparative Effectiveness of the C-MAC Video Laryngoscope versus Direct Laryngoscopy in the Setting of the Predicted Difficult Airway. https://app.cochat.ai/papers/10.1097/aln.0b013e318246ea34
The paper
Aziz, M. F., Dillman, D., Fu, R., & Brambrink, A. M. (2012). Comparative Effectiveness of the C-MAC Video Laryngoscope versus Direct Laryngoscopy in the Setting of the Predicted Difficult Airway. Anesthesiology. https://doi.org/10.1097/aln.0b013e318246ea34

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.