Routine Clinical Practice Effectiveness of the Glidescope in Difficult Airway Management: An Analysis of 2,004 Glidescope Intubations, Complications, and Failures from Two Institutions

Open access
Aziz, Michael F., Healy, David, Kheterpal, Sachin, Fu, Rongwei F., Dillman, Dawn, Brambrink, Ansgar M.·2011·Anesthesiology

Abstract

Introduction: The Glidescope video laryngoscope has been shown to be a useful tool to improve laryngeal view. However, its role in the daily routine of airway management remains poorly characterized. Methods: This investigation evaluated the use of the Glidescope at two academic medical centers. Electronic records from 71,570 intubations were reviewed, and 2,004 cases were identified where the Glidescope was used for airway management. We analyzed the success rate of Glidescope intubation in various intubation scenarios. In addition, the incidence and character of complications associated with Glidescope use were recorded. Predictors of Glidescope intubation failure were determined using a logistic regression analysis. Results: Overall success for Glidescope intubation was 97% (1,944 of 2,004). As a primary technique, success was 98% (1,712 of 1,755), whereas success in patients with predictors of difficult direct laryngoscopy was 96% (1,377 of 1,428). Success for Glidescope intubation after failed direct laryngoscopy was 94% (224 of 239). Complications were noticed in 1% (21 of 2,004) of patients and mostly involved minor soft tissue injuries, but major complications, such as dental, pharyngeal, tracheal, or laryngeal injury, occurred in 0.3% (6 of 2,004) of patients. The strongest predictor of Glidescope failure was altered neck anatomy with presence of a surgical scar, radiation changes, or mass. Conclusion: These data demonstrate a high success rate of Glidescope intubation in both primary airway management and rescue-failed direct laryngoscopy. However, Glidescope intubation is not always successful and certain predictors of failure can be identified. Providers should maintain their competency with alternate methods of intubation, especially for patients with neck pathology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aln.0b013e3182023eb7

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

See all 395

Metadata

Authors
Aziz, M. F., Healy, D., Kheterpal, S., Fu, R. F., Dillman, D., & Brambrink, A. M.
Venue
Anesthesiology
Published
2011-01-01
Volume
114
Issue
1
Pages
34-41
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2102325787
Cited by
395
References
26
FWCI
35.98
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Routine Clinical Practice Effectiveness of the Glidescope in Difficult Airway Management: An Analysis of 2,004 Glidescope Intubations, Complications, and Failures from Two Institutions. https://app.cochat.ai/papers/10.1097/aln.0b013e3182023eb7
The paper
Aziz, M. F., Healy, D., Kheterpal, S., Fu, R. F., Dillman, D., & Brambrink, A. M. (2011). Routine Clinical Practice Effectiveness of the Glidescope in Difficult Airway Management: An Analysis of 2,004 Glidescope Intubations, Complications, and Failures from Two Institutions. Anesthesiology. https://doi.org/10.1097/aln.0b013e3182023eb7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.