High Tidal Volumes in Mechanically Ventilated Patients Increase Organ Dysfunction after Cardiac Surgery
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Background: High tidal volumes in patients with acute respiratory distress syndrome and acute lung injury lead to ventilator-induced lung injury and increased mortality. We evaluated the impact of tidal volumes on cardiac surgery outcomes. Methods: We examined prospectively recorded data from 3,434 consecutive adult patients who underwent cardiac surgery. Three groups of patients were defined based on the tidal volume delivered on arrival at the intensive care unit: (1) low: below 10, (2) traditional: 10-12, and (3) high: more than 12 ml/kg of predicted body weight. We assessed risk factors for three types of organ failure (prolonged mechanical ventilation, hemodynamic instability, and renal failure) and a prolonged stay in the intensive care unit. Results: The mean tidal volume/actual weight was 9.2 ml/kg, and the tidal volume/predicted body weight was 11.5 ml/kg. Low, traditional, and high tidal volumes were used in 724 (21.1%), 1567 (45.6%), and 1,143 patients (33.3%), respectively. Independent risks factors for high tidal volumes were body mass index of 30 or more (odds ratio [OR] 6.25; CI: 5.26-7.42; P < 0.001) and female sex (OR 4.33; CI: 3.64-5.15; P < 0.001). In the multivariate analysis, high and traditional tidal volumes were independent risk factors for organ failure, multiple organ failure, and prolonged stay in the intensive care unit. Organ failures were associated with increased intensive care unit stay, hospital mortality, and long-term mortality. Conclusion: Tidal volumes of more than 10 ml/kg are risk factors for organ failure and prolonged intensive care unit stay after cardiac surgery. Women and obese patients are particularly at risk of being ventilated with injurious tidal volumes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421801 · Cited by 12,941
Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome.
Amato, M. B. P., Barbas, C. S. V., Medeiros, D. M., Magaldi, R. B., Schettino, G. P., Lorenzi-Filho, G., Kairalla, R. A., Deheinzelin, D., Munoz, C., Oliveira, R., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199802053380602 · Cited by 3,654
Ventilator-induced Lung Injury: Lessons from Experimental Studies
DREYFUSS, D., & SAUMON, G. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.1.9604014 · Cited by 2,297
Ranieri, V. M., Suter, P. M., Tortorella, C., De Tullio, R., Dayer, J. M., Brienza, A., Bruno, F., & Slutsky, A. S. (1999) · JAMA · doi:10.1001/jama.282.1.54 · Cited by 1,908
Esteban, A. (2002) · JAMA · doi:10.1001/jama.287.3.345 · Cited by 1,779
Miller, R. D. (2005) · Cited by 1,241
Bendixen, H. H., Whyte, H., & Laver, M. B. (1963) · New England Journal of Medicine · doi:10.1056/nejm196311072691901 · Cited by 745
Gajic, O., Dara, S. I., Mendez, J. L., Adesanya, A. O., Festic, E., Caples, S. M., Rana, R., St. Sauver, J. L., Lymp, J. F., Afessa, B., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000133019.52531.30 · Cited by 739
(2004) · Intensive Care Medicine · doi:10.1007/s00134-003-2121-4 · Cited by 638
Cited by
A trial of intraoperative low-tidal-volume ventilation in abdominal surgery
Futier, E., Constantin, J.-M., Paugam-Burtz, C., Pascal, J., Eurin, M., Neuschwander, A., Marret, E., Beaussier, M., Gutton, C., Lefrant, J.-Y., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1301082 · Cited by 1,434
Postoperative pulmonary complications
Miskovic, A., & Lumb, A. B. (2017) · British Journal of Anaesthesia · doi:10.1093/bja/aex002 · Cited by 1,123
Serpa Neto, A., Cardoso, S. O., Manetta, J. A., Pereira, V. G. M., Espósito, D. C., Pasqualucci, M. D. O. P., Damasceno, M. C. T., & Schultz, M. J. (2012) · JAMA · doi:10.1001/jama.2012.13730 · Cited by 843
“Our findings are in line with a recently published retrospective study of cardiac surgery patients.(38) Although it should be noted that the lower tidal volumes in that study were much higher than those used in the protective groups of the studies analyzed in this metaanalysis, a tidal volume of more than 10 mL/kg was…”
ResultGüldner, A., Kiss, T., Serpa Neto, A., Hemmes, S. N. T., Canet, J., Spieth, P. M., Rocco, P. R. M., Schultz, M. J., Pelosi, P., & Gama de Abreu, M. (2015) · Anesthesiology · doi:10.1097/aln.0000000000000754 · Cited by 432
Nadim, M. K., Forni, L. G., Bihorac, A., Hobson, C., Koyner, J. L., Shaw, A., Arnaoutakis, G. J., Ding, X., Engelman, D. T., Gasparovic, H., et al. (2018) · Journal of the American Heart Association · doi:10.1161/jaha.118.008834 · Cited by 340
Ladha, K., Vidal Melo, M. F., McLean, D. J., Wanderer, J. P., Grabitz, S. D., Kurth, T., & Eikermann, M. (2015) · BMJ · doi:10.1136/bmj.h3646 · Cited by 326
Pereira, S. M., Tucci, M. R., Morais, C. C. A., Simões, C. M., Tonelotto, B. F. F., Pompeo, M. S., Kay, F. U., Pelosi, P., Vieira, J. E., & Amato, M. B. P. (2018) · Anesthesiology · doi:10.1097/aln.0000000000002435 · Cited by 307
Neto, A. S., Hemmes, S. N., Barbas, C. S., Beiderlinden, M., Fernandez-Bustamante, A., Futier, E., Hollmann, M. W., Jaber, S., Kozian, A., Licker, M., et al. (2014) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(14)70228-0 · Cited by 302
Writing Group for the PReVENT Investigators, Simonis, F. D., Serpa Neto, A., Binnekade, J. M., Braber, A., Bruin, K. C. M., Determann, R. M., Goekoop, G.-J., Heidt, J., Horn, J., et al. (2018) · JAMA · doi:10.1001/jama.2018.14280 · Cited by 279
Needham, D. M., Yang, T., Dinglas, V. D., Mendez-Tellez, P. A., Shanholtz, C., Sevransky, J. E., Brower, R. G., Pronovost, P. J., & Colantuoni, E. (2015) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201409-1598oc · Cited by 255
Workgroup, F. T. P. Q. I. (. I., Thiele, R. H., Raghunathan, K., Brudney, C. S., Lobo, D. N., Martin, D., Senagore, A., Cannesson, M., Gan, T. J., Mythen, M. M. G., et al. (2016) · Perioperative Medicine · doi:10.1186/s13741-016-0049-9 · Cited by 197
“The concept of “lung protective ventilation” has expanded into the operating room environment and may improve outcomes in patients (Lellouche et al. 2012; Futier et al. 2013; Severgnini et al. 2013).”
BackgroundLung Injury and Acute Respiratory Distress Syndrome After Cardiac Surgery
Stephens, R. S., Shah, A. S., & Whitman, G. J. R. (2013) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2012.10.024 · Cited by 181
“More recently, Lellouche and colleagues [52] prospectively classified 3,434 cardiac surgery patients into three groups depending on whether they received low ( 10 mL/kg PBW), traditional (10 to 12 mL/kg PBW), or high ( 12 mL/kg PBW) tidal volumes after surgery.”
BackgroundMathis, M. R., Duggal, N. M., Likosky, D. S., Haft, J. W., Douville, N. J., Vaughn, M. T., Maile, M. D., Blank, R. S., Colquhoun, D. A., Strobel, R. J., et al. (2019) · Anesthesiology · doi:10.1097/aln.0000000000002909 · Cited by 173
Metadata
- Authors
- Lellouche, F., Dionne, S., Simard, S., Bussières, J., & Dagenais, F.
- Venue
- Anesthesiology
- Published
- 2012-05-01
- Volume
- 116
- Issue
- 5
- Pages
- 1072-1082
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1973121659
- Cited by
- 283
- References
- 34
- FWCI
- 23.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.