The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Surgical Navigation Technology Based on Augmented Reality and Integrated 3D Intraoperative Imaging: A Spine Cadaveric Feasibility and Accuracy Study
Open accessAbstract
STUDY DESIGN: A cadaveric laboratory study. OBJECTIVE: The aim of this study was to assess the feasibility and accuracy of thoracic pedicle screw placement using augmented reality surgical navigation (ARSN). SUMMARY OF BACKGROUND DATA: Recent advances in spinal navigation have shown improved accuracy in lumbosacral pedicle screw placement but limited benefits in the thoracic spine. 3D intraoperative imaging and instrument navigation may allow improved accuracy in pedicle screw placement, without the use of x-ray fluoroscopy, and thus opens the route to image-guided minimally invasive therapy in the thoracic spine. METHODS: ARSN encompasses a surgical table, a motorized flat detector C-arm with intraoperative 2D/3D capabilities, integrated optical cameras for augmented reality navigation, and noninvasive patient motion tracking. Two neurosurgeons placed 94 pedicle screws in the thoracic spine of four cadavers using ARSN on one side of the spine (47 screws) and free-hand technique on the contralateral side. X-ray fluoroscopy was not used for either technique. Four independent reviewers assessed the postoperative scans, using the Gertzbein grading. Morphometric measurements of the pedicles axial and sagittal widths and angles, as well as the vertebrae axial and sagittal rotations were performed to identify risk factors for breaches. RESULTS: ARSN was feasible and superior to free-hand technique with respect to overall accuracy (85% vs. 64%, P < 0.05), specifically significant increases of perfectly placed screws (51% vs. 30%, P < 0.05) and reductions in breaches beyond 4 mm (2% vs. 25%, P < 0.05). All morphometric dimensions, except for vertebral body axial rotation, were risk factors for larger breaches when performed with the free-hand method. CONCLUSION: ARSN without fluoroscopy was feasible and demonstrated higher accuracy than free-hand technique for thoracic pedicle screw placement. LEVEL OF EVIDENCE: N/A.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Cited by
Virtual, augmented, and mixed reality applications in orthopedic surgery
Verhey, J. T., Haglin, J. M., Verhey, E. M., & Hartigan, D. E. (2020) · The International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.2067 · Cited by 264
Multimodal image registration with deep context reinforcement learning
Ma, K., Wang, J., Singh, V., Tamersoy, B., Chang, Y.-J., Wimmer, A., & Chen, T. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-66182-7_28 · Cited by 87
Accuracy of augmented reality-assisted pedicle screw placement: A systematic review
Youssef, S., McDonnell, J. M., Wilson, K. V., Turley, L., Cunniffe, G., Morris, S., Darwish, S., & Butler, J. S. (2024) · European Spine Journal · doi:10.1007/s00586-023-08094-5 · Cited by 36
“Elmi-Terander et al. [5] 40/47 (85.1”
Influential
Metadata
- Authors
- Elmi-Terander, A., Skulason, H., Söderman, M., Racadio, J., Homan, R., Babic, D., van der Vaart, N., & Nachabe, R.
- Venue
- Spine
- Published
- 2016-11-01
- Volume
- 41
- Issue
- 21
- Pages
- E1303-E1311
- ISSN
- 0362-2436 (ISSN-L)
- 1528-1159
- OpenAlex
- W2513086572
- Cited by
- 160
- References
- 1
- FWCI
- 12.94
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Surgical Navigation Technology Based on Augmented Reality and Integrated 3D Intraoperative Imaging: A Spine Cadaveric Feasibility and Accuracy Study. https://app.cochat.ai/papers/10.1097/brs.0000000000001830
- The paper
- Elmi-Terander, A., Skulason, H., Söderman, M., Racadio, J., Homan, R., Babic, D., van der Vaart, N., & Nachabe, R. (2016). Surgical Navigation Technology Based on Augmented Reality and Integrated 3D Intraoperative Imaging: A Spine Cadaveric Feasibility and Accuracy Study. Spine. https://doi.org/10.1097/brs.0000000000001830
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.