CoChat

Preliminary Investigation of the Mechanisms Underlying the Effects of Manipulation: Exploration of a Multivariate Model Including Spinal Stiffness, Multifidus Recruitment, and Clinical Findings

Open access
Fritz, Julie M., Koppenhaver, Shane L., Kawchuk, Gregory N., Teyhen, Deydre S., Hebert, Jeffrey J., Childs, John D. · 2011 · Spine
Cited by 113

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

STUDY DESIGN: Prospective case series. OBJECTIVE: To examine spinal stiffness in patients with low back pain (LBP) receiving spinal manipulative therapy (SMT), evaluate associations between stiffness characteristics and clinical outcome, and explore a multivariate model of SMT mechanisms as related to effects on stiffness, lumbar multifidus (LM) recruitment, and status on a clinical prediction rule (CPR) for SMT outcomes. SUMMARY OF BACKGROUND DATA: Mechanisms underlying the clinical effects of SMT are poorly understood. Many explanations have been proposed, but few studies have related potential mechanisms to clinical outcomes or considered multiple mechanisms concurrently. METHODS: Patients with LBP were treated with two SMT sessions over 1 week. CPR status was assessed at baseline. Clinical outcome was based on the Oswestry disability index (ODI). Mechanized indentation measures of spinal stiffness and ultrasonic measures of LM recruitment were taken before and after each SMT, and after 1 week. Global and terminal stiffness were calculated. Multivariate regression was used to evaluate the relationship between stiffness variables and percentage ODI improvement. Zero-order correlations among stiffness variables, LM recruitment changes, CPR status, and clinical outcome were examined. A path analysis was used to evaluate a multivariate model of SMT effects. RESULTS: Forty-eight patients (54% women) had complete stiffness data. Significant immediate decreases in global and terminal stiffness occurred post-SMT regardless of outcome. ODI improvement was related to greater immediate decrease in global stiffness (P = 0.025), and less initial terminal stiffness (P = 0.01). Zero-order correlations and path analysis supported a multivariate model suggesting that clinical outcome of SMT is mediated by improvements in LM recruitment and immediate decrease in global stiffness. Initial terminal stiffness and CPR status may relate to outcome though their relationship with LM recruitment. CONCLUSION: The underlying mechanisms explaining the benefits of SMT appear to be multifactorial. Both spinal stiffness characteristics and LM recruitment changes appear to play a role.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/brs.0b013e318216337d

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 113

Metadata

Authors
Fritz, J. M., Koppenhaver, S. L., Kawchuk, G. N., Teyhen, D. S., Hebert, J. J., & Childs, J. D.
Venue
Spine
Published
2011-10
Volume
36
Issue
21
Pages
1772-1781
ISSN
0362-2436 (ISSN-L)
OpenAlex
W1973104730
Cited by
113
References
5
FWCI
6.68
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.