Extracorporeal Co2 Removal in Hypercapnic Patients At Risk of Noninvasive Ventilation Failure: A Matched Cohort Study With Historical Control*
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: To assess efficacy and safety of noninvasive ventilation-plus-extracorporeal Co2 removal in comparison to noninvasive ventilation-only to prevent endotracheal intubation patients with acute hypercapnic respiratory failure at risk of failing noninvasive ventilation. DESIGN: Matched cohort study with historical control. SETTING: Two academic Italian ICUs. PATIENTS: Patients treated with noninvasive ventilation for acute hypercapnic respiratory failure due to exacerbation of chronic obstructive pulmonary disease (May 2011 to November 2013). INTERVENTIONS: Extracorporeal CO2 removal was added to noninvasive ventilation when noninvasive ventilation was at risk of failure (arterial pH ≤ 7.30 with arterial PCO2 > 20% of baseline, and respiratory rate ≥ 30 breaths/min or use of accessory muscles/paradoxical abdominal movements). The noninvasive ventilation-only group was created applying the genetic matching technique (GenMatch) on a dataset including patients enrolled in two previous studies. Exclusion criteria for both groups were mean arterial pressure less than 60 mm Hg, contraindications to anticoagulation, body weight greater than 120 kg, contraindication to continuation of active treatment, and failure to obtain consent. MEASUREMENTS AND MAIN RESULTS: Primary endpoint was the cumulative prevalence of endotracheal intubation. Twenty-five patients were included in the noninvasive ventilation-plus-extracorporeal CO2 removal group. The GenMatch identified 21 patients for the noninvasive ventilation-only group. Risk of being intubated was three times higher in patients treated with noninvasive ventilation-only than in patients treated with noninvasive ventilation-plus-extracorporeal CO2 removal (hazard ratio, 0.27; 95% CI, 0.07-0.98; p = 0.047). Intubation rate in noninvasive ventilation-plus-extracorporeal CO2 removal was 12% (95% CI, 2.5-31.2) and in noninvasive ventilation-only was 33% (95% CI, 14.6-57.0), but the difference was not statistically different (p = 0.1495). Thirteen patients (52%) experienced adverse events related to extracorporeal CO2 removal. Bleeding episodes were observed in three patients, and one patient experienced vein perforation. Malfunctioning of the system caused all other adverse events. CONCLUSIONS: These data provide the rationale for future randomized clinical trials that are required to validate extracorporeal CO2 removal in patients with hypercapnic respiratory failure and respiratory acidosis nonresponsive to noninvasive ventilation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Charlson, M. E., Pompei, P., Ales, K. L., & MacKenzie, C. R. (1987) · Journal of Chronic Diseases · doi:10.1016/0021-9681(87)90171-8 · Cited by 49,742 · cited 1×
“The a priori selected variables (4, 21) were age; forced expiratory volume in the 1st second (FEV 1 ); Charlson comorbidity index (27); Simplified Acute Physiology Score (SAPS) II (28); and value of pH before institution of mechanical ventilation.”
BackgroundLe Gall, J.-R. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.270.24.2957 · Cited by 7,773 · cited 2×
“The a priori selected variables (4, 21) were age; forced expiratory volume in the 1st second (FEV 1 ); Charlson comorbidity index (27); Simplified Acute Physiology Score (SAPS) II (28); and value of pH before institution of mechanical ventilation.”
BackgroundRandomized, Controlled Trials, Observational Studies, and the Hierarchy of Research Designs
Concato, J., Shah, N., & Horwitz, R. I. (2000) · New England Journal of Medicine · doi:10.1056/nejm200006223422507 · Cited by 3,563 · cited 2×
“Although appropriate design of matched cohort study may minimize the risk of systematic overestimation of the magnitude of the treatment, the nonrandomized design remains the major limitation of the present study (35).”
BackgroundNoninvasive Ventilation for Acute Exacerbations of Chronic Obstructive Pulmonary Disease
Brochard, L., Mancebo, J., Wysocki, M., Lofaso, F., Conti, G., Rauss, A., Simonneau, G., Benito, S., Gasparetto, A., Lemaire, F., et al. (1995) · New England Journal of Medicine · doi:10.1056/nejm199509283331301 · Cited by 2,057 · cited 5×
“The clinical efficacy of NIV is based on its ability to wash out the excessive Co 2 by increasing alveolar ventilation (6).”
BackgroundMethodInfluentialNon-invasive ventilation in acute respiratory failure
Nava, S., & Hill, N. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60496-7 · Cited by 1,011
Self-citationNoninvasive Positive-Pressure Ventilation for Respiratory Failure after Extubation
Esteban, A., Frutos-Vivar, F., Ferguson, N. D., Arabi, Y., Apezteguía, C., González, M., Epstein, S. K., Hill, N. S., Nava, S., Soares, M.-A., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032736 · Cited by 894
Self-citationNoah, M. A., Peek, G. J., Finney, S. J., Griffiths, M. J., Harrison, D. A., Grieve, R., Sadique, M. Z., Sekhon, J. S., McAuley, D. F., Firmin, R. K., et al. (2011) · JAMA · doi:10.1001/jama.2011.1471 · Cited by 836
Squadrone, V., Coha, M., Cerutti, E., Schellino, M. M., Biolino, P., Occella, P., Belloni, G., Vilianis, G., Fiore, G., Cavallo, F., et al. (2005) · JAMA · doi:10.1001/jama.293.5.589 · Cited by 667
Self-citationTerragni, P. P., Del Sorbo, L., Mascia, L., Urbino, R., Martin, E. L., Birocco, A., Faggiano, C., Quintel, M., Gattinoni, L., & Ranieri, V. M. (2009) · Anesthesiology · doi:10.1097/aln.0b013e3181b764d2 · Cited by 577 · cited 2×
“, occurrence after initiation of Co 2 removal of cerebral infarction, or clinical seizure, or cerebral hemorrhage or cerebral edema]) (22).”
BackgroundMethodSelf-citationPham, T., Combes, A., Rozé, H., Chevret, S., Mercat, A., Roch, A., Mourvillier, B., Ara-Somohano, C., Bastien, O., Zogheib, E., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201205-0815oc · Cited by 500
Chandra, D., Stamm, J. A., Taylor, B., Ramos, R. M., Satterwhite, L., Krishnan, J. A., Mannino, D., Sciurba, F. C., & Holguín, F. (2012) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201106-1094oc · Cited by 418 · cited 2×
“Patients requiring transition from NIV to invasive ventilation have greater odds of death compared with patients successfully treated with NIV alone (5).”
BackgroundA chart of failure risk for noninvasive ventilation in patients with COPD exacerbation
Confalonieri, M., Garuti, G., Cattaruzza, M. S., Osborn, J. F., Antonelli, M., Conti, G., Kodric, M., Resta, O., Marchese, S., Gregoretti, C., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00085304 · Cited by 378
Keenan, S. P., Sinuff, T., Cook, D. J., & Hill, N. S. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-11-200306030-00007 · Cited by 376 · cited 6×
“Use of NIV improves outcome in patients with acute hypercapnic respiratory failure (21).”
BackgroundMethodInfluentialConti, G., Antonelli, M., Navalesi, P., Rocco, M., Bufi, M., Spadetta, G., & Meduri, G. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1478-0 · Cited by 371 · cited 2×
“30, prevalence of NIV failure ranges between 26% (6) and 52% (3).”
BackgroundResultKluge, S., Braune, S. A., Engel, M., Nierhaus, A., Frings, D., Ebelt, H., Uhrig, A., Metschke, M., Wegscheider, K., Suttorp, N., et al. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2649-2 · Cited by 201 · cited 2×
“Extracorporeal circuits designed to remove Co 2 (extracorporeal Co 2 removal [ECCO 2 R]) have been used in patients with acute hypercapnic respiratory failure (7–20) since ECCO 2 R should enhance the efficacy of NIV to remove Co 2 (8, 10, 16, 20) and avoid the worsening of respiratory acidosis (4, 21).”
MethodSquadrone, E., Frigerio, P., Fogliati, C., Gregoretti, C., Conti, G., Antonelli, M., Costa, R., Baiardi, P., & Navalesi, P. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2320-7 · Cited by 188 · cited 1×
“This value is consistent with predictive models (4) and previous studies (2, 3).”
ResultAbrams, D. C., Brenner, K., Burkart, K. M., Agerstrand, C. L., Thomashow, B. M., Bacchetta, M., & Brodie, D. (2013) · Annals of the American Thoracic Society · doi:10.1513/annalsats.201301-021oc · Cited by 160
A matching method for improving covariate balance in cost‐effectiveness analyses
Sekhon, J. S., & Grieve, R. (2011) · Health Economics · doi:10.1002/hec.1748 · Cited by 138 · cited 3×
“The genetic matching method without replacement (GenMatch) was used to match patients treated with “NIV-plusECCo 2 R” and “NIV-only” (29, 30).”
MethodInfluentialAmbulatory veno-venous extracorporeal membrane oxygenation: Innovation and pitfalls
Garcia, J. P., Kon, Z. N., Evans, C. F., Wu, Z. J., Iacono, A. T., McCormick, B. M., & Griffith, B. P. (2011) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2011.07.029 · Cited by 130 · cited 1×
“ICU length of stay (d) 8 (7, 10) 12 (6, 15) 0.”
Role and potentials of low-flow CO2 removal system in mechanical ventilation
Terragni, P., Maiolo, G., & Ranieri, V. M. (2011) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e32834f17ef · Cited by 85 · cited 1×
“Furthermore, we excluded those patients in whom ECCO 2 R would have been hard to be implemented (mean arterial pressure < 60 mm Hg, body weight > 120 kg) or not recommended (risk of bleeding or contraindication to continuation of active treatment) (18).”
BackgroundSelf-citationRemoving extra CO2 in COPD patients
LUND, L. W., & Federspiel, W. J. (2013) · Current Respiratory Care Reports · doi:10.1007/s13665-013-0057-x · Cited by 59 · cited 2×
“Extracorporeal circuits designed to remove Co 2 (extracorporeal Co 2 removal [ECCO 2 R]) have been used in patients with acute hypercapnic respiratory failure (7–20) since ECCO 2 R should enhance the efficacy of NIV to remove Co 2 (8, 10, 16, 20) and avoid the worsening of respiratory acidosis (4, 21).”
BackgroundMethodRadice, R., Ramsahai, R. R., Grieve, R., Kreif, N., Sadique, Z., & Sekhon, J. S. (2012) · The International Journal of Biostatistics · doi:10.1515/1557-4679.1382 · Cited by 55 · cited 1×
“In comparison to propensity score matching, GenMatch achieves the best covariate balance (32) and minimizes bias related to data replacement or arbitrary caliper matching (33).”
BackgroundAntro, C., Merico, F., Urbino, R., & Gai, V. (2005) · Emergency Medicine Journal · doi:10.1136/emj.2004.018309 · Cited by 46 · cited 3×
“NIV-Only A dataset for matched cohort analysis was created using patients treated with “NIV-only” for COPD and acute hypercapnic respiratory failure enrolled in two previous studies performed in the same institutions where the present investigation was carried out (23, 24).”
MethodSelf-citationRespiratory Dialysis for Avoidance of Intubation in Acute Exacerbation of COPD
Mani, R. K., Schmidt, W. W., LUND, L. W., & Herth, F. J. F. (2013) · ASAIO Journal · doi:10.1097/mat.0000000000000004 · Cited by 25 · cited 1×
“Extracorporeal circuits designed to remove Co 2 (extracorporeal Co 2 removal [ECCO 2 R]) have been used in patients with acute hypercapnic respiratory failure (7–20) since ECCO 2 R should enhance the efficacy of NIV to remove Co 2 (8, 10, 16, 20) and avoid the worsening of respiratory acidosis (4, 21).”
Method
Cited by
Extracorporeal membrane oxygenation: evolving epidemiology and mortality
Karagiannidis, C., Brodie, D., Strassmann, S., Stoelben, E., Philipp, A., Bein, T., Müller, T., & Windisch, W. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4273-z · Cited by 463
BTS/ICS guideline for the ventilatory management of acute hypercapnic respiratory failure in adults
Davidson, A. C., Banham, S., Elliott, M., Kennedy, D., Gelder, C., Glossop, A., Church, A. C., Creagh-Brown, B., Dodd, J. W., Felton, T., et al. (2016) · Thorax · doi:10.1136/thoraxjnl-2015-208209 · Cited by 426
Extracorporeal Life Support for Adults With Respiratory Failure and Related Indications: A Review
Brodie, D., Slutsky, A. S., & Combes, A. (2019) · JAMA · doi:10.1001/jama.2019.9302 · Cited by 391
MacLeod, M., Papi, A., Contoli, M., Beghé, B., Celli, B. R., Wedzicha, J. A., & Fabbri, L. M. (2021) · Respirology · doi:10.1111/resp.14041 · Cited by 359
DAS-Taskforce, Baron, R., Binder, A., Biniek, R., Braune, S. A., Buerkle, H., Dall, P., Demirakca, S., Eckardt, R., Eggers, V., et al. (2015) · Europe PMC (PubMed Central) · doi:10.3205/000223 · Cited by 319
Metadata
- Authors
- Del Sorbo, L., Pisani, L., Filippini, C., Fanelli, V., Fasano, L., Terragni, P., Dell’Amore, A., Urbino, R., Mascia, L., Evangelista, A., Antro, C., D’Amato, R., Sucre, M. J., Simonetti, U., Persico, P., Nava, S., & Ranieri, V. M.
- Venue
- Critical Care Medicine
- Published
- 2015-01
- Volume
- 43
- Issue
- 1
- Pages
- 120-127
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2091958988
- Cited by
- 184
- References
- 24
- FWCI
- 18.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.