Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 577

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Tidal Volume Lower than 6 ml/kg Enhances Lung Protection: Role of Extracorporeal Carbon Dioxide Removal

Open access
Terragni, Pier Paolo, Del Sorbo, Lorenzo, Mascia, Luciana, Urbino, Rosario, Martin, Erica L., Birocco, Alberto, Faggiano, Chiara, Quintel, Michael, Gattinoni, Luciano, Ranieri, V Marco·2009·Anesthesiology

Abstract

Background: Tidal hyperinflation may occur in patients with acute respiratory distress syndrome who are ventilated with a tidal volume (VT) of 6 ml/kg of predicted body weight develop a plateau pressure (PPLAT) of 28 < or = PPLAT < or = 30 cm H2O. The authors verified whether VT lower than 6 ml/kg may enhance lung protection and that consequent respiratory acidosis may be managed by extracorporeal carbon dioxide removal. Methods: PPLAT, lung morphology computed tomography, and pulmonary inflammatory cytokines (bronchoalveolar lavage) were assessed in 32 patients ventilated with a VT of 6 ml/kg. Data are provided as mean +/- SD or median and interquartile (25th and 75th percentile) range. In patients with 28 < or = PPLAT < or = 30 cm H2O (n = 10), VT was reduced from 6.3 +/- 0.2 to 4.2 +/- 0.3 ml/kg, and PPLAT decreased from 29.1 +/- 1.2 to 25.0 +/- 1.2 cm H2O (P < 0.001); consequent respiratory acidosis (Paco2 from 48.4 +/- 8.7 to 73.6 +/- 11.1 mmHg and pH from 7.36 +/- 0.03 to 7.20 +/- 0.02; P < 0.001) was managed by extracorporeal carbon dioxide removal. Lung function, morphology, and pulmonary inflammatory cytokines were also assessed after 72 h. Results: Extracorporeal assist normalized Paco2 (50.4 +/- 8.2 mmHg) and pH (7.32 +/- 0.03) and allowed use of VT lower than 6 ml/kg for 144 (84-168) h. The improvement of morphological markers of lung protection and the reduction of pulmonary cytokines concentration (P < 0.01) were observed after 72 h of ventilation with VT lower than 6 ml/kg. No patient-related complications were observed. Conclusions: VT lower than 6 ml/Kg enhanced lung protection. Respiratory acidosis consequent to low VT ventilation was safely and efficiently managed by extracorporeal carbon dioxide removal.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aln.0b013e3181b764d2

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Cited by

See all 577

Metadata

Authors
Terragni, P. P., Del Sorbo, L., Mascia, L., Urbino, R., Martin, E. L., Birocco, A., Faggiano, C., Quintel, M., Gattinoni, L., & Ranieri, V. M.
Venue
Anesthesiology
Published
2009-10-01
Volume
111
Issue
4
Pages
826-835
ISSN
0003-3022 (ISSN-L)
OpenAlex
W1979469936
Cited by
577
References
32
FWCI
24.90
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Tidal Volume Lower than 6 ml/kg Enhances Lung Protection: Role of Extracorporeal Carbon Dioxide Removal. https://app.cochat.ai/papers/10.1097/aln.0b013e3181b764d2
The paper
Terragni, P. P., Del Sorbo, L., Mascia, L., Urbino, R., Martin, E. L., Birocco, A., Faggiano, C., Quintel, M., Gattinoni, L., & Ranieri, V. M. (2009). Tidal Volume Lower than 6 ml/kg Enhances Lung Protection: Role of Extracorporeal Carbon Dioxide Removal. Anesthesiology. https://doi.org/10.1097/aln.0b013e3181b764d2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.