Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 290

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Use of High-Flow Nasal Cannula Oxygen Therapy to Prevent Desaturation During Tracheal Intubation of Intensive Care Patients With Mild-to-Moderate Hypoxemia*

Miguel-Montanes, Romain, Hajage, David, Messika, Jonathan, Bertrand, Fabrice, Gaudry, Stéphane, Rafat, Cédric, Labbé, Vincent, Dufour, Nicolas, Jean-Baptiste, Sylvain, Bedet, Alexandre, Dreyfuss, Didier, Ricard, Jean-Damien · 2015 · Critical Care Medicine

Abstract

OBJECTIVES: Tracheal intubation of ICU patients is frequently associated with severe hypoxemia. Although noninvasive ventilation reduces desaturation during intubation of severely hypoxemic patients, it does not allow for per-procedure oxygenation and has not been evaluated in mild-to-moderate hypoxemic patients for whom high-flow nasal cannula oxygen may be an alternative. We sought to compare pre- and per-procedure oxygenation with either a nonrebreathing bag reservoir facemask or a high-flow nasal cannula oxygen during tracheal intubation of ICU patients. DESIGN: Prospective quasi-experimental before-after study (ClinicalTrials.gov: NCT01699880). SETTING: University hospital medico-surgical ICU. PATIENTS: All adult patients requiring tracheal intubation in the ICU were eligible. INTERVENTIONS: In the control (before) period, preoxygenation was performed with a nonrebreathing bag reservoir facemask and in the change of practice (after) period, with high-flow nasal cannula oxygen. MEASUREMENTS AND MAIN RESULTS: Primary outcome was median lowest SpO2 during intubation, and secondary outcomes were SpO2 after preoxygenation and number of patients with saturation less than 80%. One hundred one patients were included. Median lowest SpO2 during intubation were 94% (83-98.5) with the nonrebreathing bag reservoir facemask versus 100% (95-100) with high-flow nasal cannula oxygen (p < 0.0001). SpO2 values at the end of preoxygenation were higher with high-flow nasal cannula oxygen than with nonrebreathing bag reservoir facemask and were correlated with the lowest SpO2 reached during the intubation procedure (r = 0.38, p < 0.0001). Patients in the nonrebreathing bag reservoir facemask group experienced more episodes of severe hypoxemia (2% vs 14%, p = 0.03). In the multivariate analysis, preoxygenation with high-flow nasal cannula oxygen was an independent protective factor of the occurrence of severe hypoxemia (odds ratio, 0.146; 95% CI, 0.01-0.90; p = 0.037). CONCLUSIONS: High-flow nasal cannula oxygen significantly improved preoxygenation and reduced prevalence of severe hypoxemia compared with nonrebreathing bag reservoir facemask. Its use could improve patient safety during intubation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0000000000000743

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Cited by

See all 290

Metadata

Authors
Miguel-Montanes, R., Hajage, D., Messika, J., Bertrand, F., Gaudry, S., Rafat, C., Labbé, V., Dufour, N., Jean-Baptiste, S., Bedet, A., Dreyfuss, D., & Ricard, J.-D.
Venue
Critical Care Medicine
Published
2015-03
Volume
43
Issue
3
Pages
574-583
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2155158289
Cited by
290
References
31
FWCI
48.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of High-Flow Nasal Cannula Oxygen Therapy to Prevent Desaturation During Tracheal Intubation of Intensive Care Patients With Mild-to-Moderate Hypoxemia*. https://app.cochat.ai/papers/10.1097/ccm.0000000000000743
The paper
Miguel-Montanes, R., Hajage, D., Messika, J., Bertrand, F., Gaudry, S., Rafat, C., Labbé, V., Dufour, N., Jean-Baptiste, S., Bedet, A., Dreyfuss, D., & Ricard, J.-D. (2015). Use of High-Flow Nasal Cannula Oxygen Therapy to Prevent Desaturation During Tracheal Intubation of Intensive Care Patients With Mild-to-Moderate Hypoxemia*. Critical Care Medicine. https://doi.org/10.1097/ccm.0000000000000743

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.