CoChat

Lactate Testing in Suspected Sepsis: Trends and Predictors of Failure to Measure Levels

Open access
Rhee, Chanu, Murphy, Michael V., Li, Lingling, Platt, Richard, Klompas, Michael · 2015 · Critical Care Medicine
Cited by 39

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: Serum lactate monitoring is central to risk stratification and management of sepsis and is now part of a potential quality measure. We examined 11-year trends in lactate testing and predictors of failure to measure lactates in patients with severe sepsis. DESIGN: Retrospective cohort study. SETTING: Two U.S. academic hospitals. PATIENTS: Adult patients admitted from 2003 to 2013. INTERVENTIONS: Annual rates of lactate measurement were assessed in patients who had blood cultures ordered and patients with severe sepsis, as defined by concomitant International Classification of Diseases, Ninth Revision codes for infection and organ dysfunction. The approximate time of suspected sepsis was determined by the first blood culture order with concurrent antibiotic initiation. Multivariate analysis was performed to identify predictors of failure to measure lactates in severe sepsis cases in 2013. MEASUREMENTS AND MAIN RESULTS: Among hospitalizations with blood culture orders, rates of lactate measurement increased from 11% in 2003 to 48% in 2013 (p < 0.001 for linear trend). Rates of repeat lactate measurement within 6 hours after lactate levels greater than or equal to 4.0 mmol/L increased from 23% to 69% (p < 0.001). Patients were progressively less likely to be on vasopressors at the time of first lactate measurement (49% in 2003 vs 21% in 2013; p < 0.001). Despite these trends, lactates were measured at the time of suspected sepsis in only 65% of patients with severe sepsis in 2013. On multivariate analysis, hospital-onset sepsis and hospitalization on a nonmedical service were significant predictors of failure to measure lactates (adjusted odds ratio, 7.56; 95% CI, 6.31-9.06 and adjusted odds ratio, 2.08; 95% CI, 1.76-2.24, respectively). CONCLUSIONS: Lactate testing has increased dramatically over time and is being extended to patients without overt shock. However, rates of serial lactate testing are still suboptimal, and lactates are not being measured in many patients with severe sepsis. Hospital-onset sepsis and nonmedical units may be high-yield targets for quality improvement initiatives.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0000000000001087

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 39

Metadata

Authors
Rhee, C., Murphy, M. V., Li, L., Platt, R., & Klompas, M.
Venue
Critical Care Medicine
Published
2015-08
Volume
43
Issue
8
Pages
1669-1676
ISSN
0090-3493 (ISSN-L)
OpenAlex
W1950755547
Cited by
39
References
5
FWCI
2.75
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Lactate Testing in Suspected Sepsis: Trends and Predictors of Failure to Measure Levels. https://app.cochat.ai/papers/10.1097/ccm.0000000000001087
The paper
Rhee, C., Murphy, M. V., Li, L., Platt, R., & Klompas, M. (2015). Lactate Testing in Suspected Sepsis: Trends and Predictors of Failure to Measure Levels. Critical Care Medicine. https://doi.org/10.1097/ccm.0000000000001087

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.