A Time-Phased Machine Learning Model for Real-Time Prediction of Sepsis in Critical Care
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Objectives: As a life-threatening condition, sepsis is one of the major public health issues worldwide. Early prediction can improve sepsis outcomes with appropriate interventions. With the PhysioNet/Computing in Cardiology Challenge 2019, we aimed to develop and validate a machine learning algorithm with high prediction performance and clinical interpretability for prediction of sepsis onset during critical care in real-time. Design: Retrospective observational cohort study. Setting: The dataset was collected from three ICUs in three different U.S. hospitals. Two of them were publicly available for model development (offline) and one was used for testing (online). Patients: Forty-thousand three-hundred thirty-six ICU patients from the two model development databases and 24,819 from the test database. There are up to 40 hourly-recorded clinical variables for each ICU stay. The Sepsis-3 criteria were used to confirm sepsis onset. Interventions: None. Measurements and Main Results: Three-hundred twelve features were constructed hourly as the input of our proposed Time-phAsed machine learning model for Sepsis Prediction. Time-phAsed machine learning model for Sepsis Prediction first estimates the likelihood of sepsis onset for each hour of an ICU stay in the following 6 hours, and then makes a binary prediction with three time-phased cutoff values. On the internal validation set, the utility score (official challenge measurement) achieved by Time-phAsed machine learning model for Sepsis Prediction was 0.430. On the test set, the utility score reached was 0.354. Furthermore, Time-phAsed machine learning model for Sepsis Prediction provides an intuitive way to illustrate the impact of the input features on the outcome prediction, which makes it clinically interpretable. Conclusions: The proposed Time-phAsed machine learning model for Sepsis Prediction model is accurate and interpretable for real-time prediction of sepsis onset in critical care, which holds great potential for further evaluation in prospective studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An interpretable machine learning model for accurate prediction of sepsis in the ICU
Nemati, S., Holder, A., Razmi, F., Stanley, M. D., Clifford, G. D., & Buchman, T. G. (2018) · Critical Care Medicine · doi:10.1097/ccm.0000000000002936 · Cited by 832
Desautels, T., Calvert, J., Hoffman, J., Jay, M., Kerem, Y., Shieh, L., Shimabukuro, D., Chettipally, U., Feldman, M. D., Barton, C., et al. (2016) · JMIR Medical Informatics · doi:10.2196/medinform.5909 · Cited by 509
Shimabukuro, D. W., Barton, C. W., Feldman, M. D., Mataraso, S. J., & Das, R. (2017) · BMJ Open Respiratory Research · doi:10.1136/bmjresp-2017-000234 · Cited by 382
Mao, Q., Jay, M., Hoffman, J. L., Calvert, J., Barton, C., Shimabukuro, D., Shieh, L., Chettipally, U., Fletcher, G., Kerem, Y., et al. (2018) · BMJ Open · doi:10.1136/bmjopen-2017-017833 · Cited by 336
Horng, S., Sontag, D. A., Halpern, Y., Jernite, Y., Shapiro, N. I., & Nathanson, L. A. (2017) · PLOS ONE · doi:10.1371/journal.pone.0174708 · Cited by 310
Giannini, H. M., Ginestra, J. C., Chivers, C., Draugelis, M., Hanish, A., Schweickert, W. D., Fuchs, B. D., Meadows, L., Lynch, M., Donnelly, P. J., et al. (2019) · Critical Care Medicine · doi:10.1097/ccm.0000000000003891 · Cited by 269
Should Health Care Demand Interpretable Artificial Intelligence or Accept “Black Box” Medicine?
Wang, F., Kaushal, R., & Khullar, D. (2020) · Annals of Internal Medicine · doi:10.7326/m19-2548 · Cited by 244
Self-citationGinestra, J. C., Giannini, H. M., Schweickert, W. D., Meadows, L., Lynch, M. J., Pavan, K., Chivers, C. J., Draugelis, M., Donnelly, P. J., Fuchs, B. D., et al. (2019) · Critical Care Medicine · doi:10.1097/ccm.0000000000003803 · Cited by 159
Cited by
Machine learning model to predict mental health crises from electronic health records
Garriga, R., Mas, J., Abraha, S., Nolan, J., Harrison, O., Tadros, G., & Matic, A. (2022) · Nature Medicine · doi:10.1038/s41591-022-01811-5 · Cited by 229
“Running predictions continuously 13,14 provides an updated risk score based on the latest available data, which typically contains the most predictive information, which is, in the case of mental health, crucial to improving healthcare management and outcomes.”
BackgroundJiang, Z., Bo, L., Wang, L., Xie, Y., Cao, J., Yao, Y., Lu, W., Deng, X., Yang, T., & Bian, J. (2023) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2023.107772 · Cited by 38
Wang, Y., Gao, Z., Zhang, Y., Lu, Z., & Sun, F. (2025) · Internal and Emergency Medicine · doi:10.1007/s11739-024-03732-2 · Cited by 29
Cross-Hospital Sepsis Early Detection via Semi-Supervised Optimal Transport With Self-Paced Ensemble
Ding, R., Zhou, Y., Xu, J., Xie, Y., Liang, Q., Ren, H., Wang, Y., Chen, Y., Wang, L., & Huang, M. (2023) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2023.3253208 · Cited by 20
“Specifically, we extracted the first 48-hour data since patients entered ICUs.”
BackgroundMethodInfluentialAn Explainable Machine Learning Model for Early Prediction of Sepsis Using ICU Data
Nesaragi, N., & Patidar, S. (2021) · Infections and Sepsis Development · doi:10.5772/intechopen.98957 · Cited by 11
Metadata
- Authors
- Li, X., Xu, X., Xie, F., Xu, X., Sun, Y., Liu, X., Jia, X., Kang, Y., Xie, L., Wang, F., & Xie, G.
- Venue
- Critical Care Medicine
- Published
- 2020-06-26
- Volume
- 48
- Issue
- 10
- Pages
- e884-e888
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W3047528319
- Cited by
- 82
- References
- 8
- FWCI
- 7.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Time-Phased Machine Learning Model for Real-Time Prediction of Sepsis in Critical Care. https://app.cochat.ai/papers/10.1097/ccm.0000000000004494
- The paper
- Li, X., Xu, X., Xie, F., Xu, X., Sun, Y., Liu, X., Jia, X., Kang, Y., Xie, L., Wang, F., & Xie, G. (2020). A Time-Phased Machine Learning Model for Real-Time Prediction of Sepsis in Critical Care. Critical Care Medicine. https://doi.org/10.1097/ccm.0000000000004494
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.