CoChat

An Explainable Artificial Intelligence Predictor for Early Detection of Sepsis

Yang, Meicheng, Liu, Chengyu, Wang, Xingyao, Li, Yuwen, Gao, Hongxiang, Liu, Xing, Li, Jianqing · 2020 · Critical Care Medicine
Cited by 118

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

Objectives: Early detection of sepsis is critical in clinical practice since each hour of delayed treatment has been associated with an increase in mortality due to irreversible organ damage. This study aimed to develop an explainable artificial intelligence model for early predicting sepsis by analyzing the electronic health record data from ICU provided by the PhysioNet/Computing in Cardiology Challenge 2019. Design: Retrospective observational study. Setting: We developed our model on the shared ICUs publicly data and verified on the full hidden populations for challenge scoring. Patients: Public database included 40,336 patients’ electronic health records sourced from Beth Israel Deaconess Medical Center (hospital system A) and Emory University Hospital (hospital system B). A total of 24,819 patients from hospital systems A, B, and C (an unidentified hospital system) were sequestered as full hidden test sets. Interventions: None. Measurements and Main Results: A total of 168 features were extracted on hourly basis. Explainable artificial intelligence sepsis predictor model was trained to predict sepsis in real time. Impact of each feature on hourly sepsis prediction was explored in-depth to show the interpretability. The algorithm demonstrated the final clinical utility score of 0.364 in this challenge when tested on the full hidden test sets, and the scores on three separate test sets were 0.430, 0.422, and –0.048, respectively. Conclusions: Explainable artificial intelligence sepsis predictor model achieves superior performance for predicting sepsis risk in a real-time way and provides interpretable information for understanding sepsis risk in ICU.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0000000000004550

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 118

Metadata

Authors
Yang, M., Liu, C., Wang, X., Li, Y., Gao, H., Liu, X., & Li, J.
Venue
Critical Care Medicine
Published
2020-08-07
Volume
48
Issue
11
Pages
e1091-e1096
ISSN
0090-3493 (ISSN-L)
OpenAlex
W3048074762
Cited by
118
References
14
FWCI
6.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An Explainable Artificial Intelligence Predictor for Early Detection of Sepsis. https://app.cochat.ai/papers/10.1097/ccm.0000000000004550
The paper
Yang, M., Liu, C., Wang, X., Li, Y., Gao, H., Liu, X., & Li, J. (2020). An Explainable Artificial Intelligence Predictor for Early Detection of Sepsis. Critical Care Medicine. https://doi.org/10.1097/ccm.0000000000004550

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.