CoChat

Anemia causes hypoglycemia in intensive care unit patients due to error in single-channel glucometers: Methods of reducing patient risk*

Open access
Pidcoke, Heather F., Wade, Charles E., Mann, Elizabeth A., Salinas, Jose, Cohee, Brian M., Holcomb, John B., Wolf, Steven E. · 2010 · Critical Care Medicine
Cited by 60

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Intensive insulin therapy in the critically ill reduces mortality but carries the risk of increased hypoglycemia. Point-of-care blood glucose analysis is standard; however, anemia causes falsely high values and potentially masks hypoglycemia. Permissive anemia is practiced routinely in most intensive care units. We hypothesized that point-of-care glucometer error due to anemia is prevalent, can be corrected mathematically, and correction uncovers occult hypoglycemia during intensive insulin therapy. DESIGN: The study has both retrospective and prospective phases. We reviewed data to verify the presence of systematic error, determine the source of error, and establish the prevalence of anemia. We confirmed our findings by reproducing the error in an in vitro model. Prospective data were used to develop a correction formula validated by the Monte Carlo method. Correction was implemented in a burn intensive care unit and results were evaluated after 9 mos. SETTING: Burn and trauma intensive care units at a single research institution. PATIENTS/SUBJECTS: Samples for in vitro studies were taken from healthy volunteers. Samples for formula development were from critically ill patients who received intensive insulin therapy. INTERVENTIONS: Insulin doses were calculated based on predicted serum glucose values from corrected point-of-care glucometer measurements. MEASUREMENTS AND MAIN RESULTS: Time-matched point-of-care glucose, laboratory glucose, and hematocrit values. We previously found that anemia (hematocrit <34%) produces systematic error in glucometer measurements. The error was correctible with a mathematical formula developed and validated, using prospectively collected data. Error of uncorrected point-of-care glucose ranged from 19% to 29% (p < .001), improving to < or = 5% after mathematical correction of prospective data. Comparison of data pairs before and after correction formula implementation demonstrated a 78% decrease in the prevalence of hypoglycemia in critically ill and anemic patients treated with insulin and tight glucose control (p < .001). CONCLUSIONS: A mathematical formula that corrects erroneous point-of-care glucose values due to anemia in intensive care unit patients reduces the prevalence of hypoglycemia during intensive insulin therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e3181bc826f

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 60

Metadata

Authors
Pidcoke, H. F., Wade, C. E., Mann, E. A., Salinas, J., Cohee, B. M., Holcomb, J. B., & Wolf, S. E.
Venue
Critical Care Medicine
Published
2010-02
Volume
38
Issue
2
Pages
471-476
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2021138123
Cited by
60
References
5
FWCI
7.49
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Anemia causes hypoglycemia in intensive care unit patients due to error in single-channel glucometers: Methods of reducing patient risk*. https://app.cochat.ai/papers/10.1097/ccm.0b013e3181bc826f
The paper
Pidcoke, H. F., Wade, C. E., Mann, E. A., Salinas, J., Cohee, B. M., Holcomb, J. B., & Wolf, S. E. (2010). Anemia causes hypoglycemia in intensive care unit patients due to error in single-channel glucometers: Methods of reducing patient risk*. Critical Care Medicine. https://doi.org/10.1097/ccm.0b013e3181bc826f

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.