Different assessment tools for intensive care unit delirium: Which score to use?*

Luetz, Alawi, Heymann, Anja, Radtke, Finn M., Chenitir, Chokri, Neuhaus, Ulrike, Nachtigall, Irit, von Dossow, Vera, Marz, Susanne, Eggers, Verena, Heinz, Andreas, Wernecke, Klaus D., Spies, Claudia D.·2010·Critical Care Medicine

Abstract

OBJECTIVE: To compare validity and reliability of three instruments for detection and assessment of delirium in intensive care unit (ICU) patients. Delirium in critically ill patients is associated with higher mortality, prolonged duration of ICU stay, and greater healthcare costs. Currently, there are several assessment tools available for detection of delirium, but only a few of these assessment systems are developed specifically to screen for delirium in ICU patients. DESIGN: Prospective cohort study. SETTING: ICU at a university hospital. PATIENTS: A total of 156 surgical patients aged > or = 60 yrs consecutively admitted to the ICU, with a length of stay of at least 24 hrs. MEASUREMENTS AND MAIN RESULTS: This study was approved by the institutional ethics committee. Trained staff members performed daily and independently the Confusion Assessment Method for the ICU (CAM-ICU), the Nursing Delirium Screening Scale (Nu-DESC), and the Delirium Detection Score (DDS). These evaluations were compared against the reference standard conducted by a delirium expert (blinded to the study), who used delirium criteria from the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV). Of 156 patients, 63 (40%) were identified as delirious by the reference standard during the study. Using the CAM-ICU and the Nu-DESC, we measured comparable sensitivities (CAM-ICU, 81%; Nu-DESC, 83%). The specificity of the CAM-ICU was significantly higher than that of the Nu-DESC (96% vs. 81%, p < .01). In contrast, the DDS showed poor sensitivity (30%), whereas the specificity was significantly higher compared with the Nu-DESC (DDS, 91%; Nu-DESC, 81%, p < .05). The interrater reliability was "almost perfect" for the CAM-ICU (kappa = 0.89) and "substantial" for DDS and Nu-DESC (kappa = 0.79, 0.68). CONCLUSION: The CAM-ICU showed the best validity of the evaluated scales to identify delirium in ICU patients. The Nu-DESC might be an alternative tool for detection of ICU delirium. The DDS should not be used as a screening tool.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e3181cabb42

Cites

54 of 54 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 54 references

Cited by

See all 327

Metadata

Authors
Luetz, A., Heymann, A., Radtke, F. M., Chenitir, C., Neuhaus, U., Nachtigall, I., von Dossow, V., Marz, S., Eggers, V., Heinz, A., Wernecke, K. D., & Spies, C. D.
Venue
Critical Care Medicine
Published
2010-02
Volume
38
Issue
2
Pages
409-418
ISSN
0090-3493 (ISSN-L)
OpenAlex
W1995968154
Cited by
327
References
54
FWCI
23.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Different assessment tools for intensive care unit delirium: Which score to use?*. https://app.cochat.ai/papers/10.1097/ccm.0b013e3181cabb42
The paper
Luetz, A., Heymann, A., Radtke, F. M., Chenitir, C., Neuhaus, U., Nachtigall, I., von Dossow, V., Marz, S., Eggers, V., Heinz, A., Wernecke, K. D., & Spies, C. D. (2010). Different assessment tools for intensive care unit delirium: Which score to use?*. Critical Care Medicine. https://doi.org/10.1097/ccm.0b013e3181cabb42

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.