The DOI matches its Crossref record.
Functional definition and characterization of acute traumatic coagulopathy
Open accessAbstract
OBJECTIVE: To identify an appropriate diagnostic tool for the early diagnosis of acute traumatic coagulopathy and validate this modality through prediction of transfusion requirements in trauma hemorrhage. DESIGN: Prospective observational cohort study. SETTING: Level 1 trauma center. PATIENTS: Adult trauma patients who met the local criteria for full trauma team activation. Exclusion criteria included emergency department arrival >2 hrs after injury, >2000 mL of intravenous fluid before emergency department arrival, or transfer from another hospital. INTERVENTIONS: None. MEASUREMENTS: Blood was collected on arrival in the emergency department and analyzed with laboratory prothrombin time, point-of-care prothrombin time, and rotational thromboelastometry. Prothrombin time ratio was calculated and acute traumatic coagulopathy defined as laboratory prothrombin time ratio >1.2. Transfusion requirements were recorded for the first 12 hrs following admission. MAIN RESULTS: Three hundred patients were included in the study. Laboratory prothrombin time results were available at a median of 78 (62-103) mins. Point-of-care prothrombin time ratio had reduced agreement with laboratory prothrombin time ratio in patients with acute traumatic coagulopathy, with 29% false-negative results. In acute traumatic coagulopathy, the rotational thromboelastometry clot amplitude at 5 mins was diminished by 42%, and this persisted throughout clot maturation. Rotational thromboelastometry clotting time was not significantly prolonged. Clot amplitude at a 5-min threshold of ≤35 mm had a detection rate of 77% for acute traumatic coagulopathy with a false-positive rate of 13%. Patients with clot amplitude at 5 mins ≤35 mm were more likely to receive red cell (46% vs. 17%, p < .001) and plasma (37% vs. 11%, p < .001) transfusions. The clot amplitude at 5 mins could identify patients who would require massive transfusion (detection rate of 71%, vs. 43% for prothrombin time ratio >1.2, p < .001). CONCLUSIONS: In trauma hemorrhage, prothrombin time ratio is not rapidly available from the laboratory and point-of-care devices can be inaccurate. Acute traumatic coagulopathy is functionally characterized by a reduction in clot strength. With a threshold of clot amplitude at 5 mins of ≤35 mm, rotational thromboelastometry can identify acute traumatic coagulopathy at 5 mins and predict the need for massive transfusion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
TEG and ROTEM: Technology and clinical applications
Whiting, D., & DiNardo, J. A. (2014) · American Journal of Hematology · doi:10.1002/ajh.23599 · Cited by 688
Haas, T., Fries, D., Tanaka, K. A., Asmis, L., Curry, N. S., & Schöchl, H. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aeu303 · Cited by 249
Walsh, M., Fritz, S., Hake, D., Son, M., Greve, S., Jbara, M., Chitta, S., Fritz, B., Miller, A., K Bader, M., et al. (2016) · Current Drug Targets · doi:10.2174/1389450117666160310153211 · Cited by 58
Metadata
- Authors
- Davenport, R., Manson, J., DeʼAth, H., Platton, S., Coates, A., Allard, S., Hart, D., Pearse, R., Pasi, K. J., MacCallum, P., Stanworth, S., & Brohi, K.
- Venue
- Critical Care Medicine
- Published
- 2011-12
- Volume
- 39
- Issue
- 12
- Pages
- 2652-2658
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2136753837
- Cited by
- 520
- References
- 0
- FWCI
- 31.60
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Functional definition and characterization of acute traumatic coagulopathy. https://app.cochat.ai/papers/10.1097/ccm.0b013e3182281af5
- The paper
- Davenport, R., Manson, J., DeʼAth, H., Platton, S., Coates, A., Allard, S., Hart, D., Pearse, R., Pasi, K. J., MacCallum, P., Stanworth, S., & Brohi, K. (2011). Functional definition and characterization of acute traumatic coagulopathy. Critical Care Medicine. https://doi.org/10.1097/ccm.0b013e3182281af5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.