The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Both high level pressure support ventilation and controlled mechanical ventilation induce diaphragm dysfunction and atrophy
Open accessAbstract
OBJECTIVES: Previous workers have demonstrated that controlled mechanical ventilation results in diaphragm inactivity and elicits a rapid development of diaphragm weakness as a result of both contractile dysfunction and fiber atrophy. Limited data exist regarding the impact of pressure support ventilation, a commonly used mode of mechanical ventilation-that permits partial mechanical activity of the diaphragm-on diaphragm structure and function. We carried out the present study to test the hypothesis that high-level pressure support ventilation decreases the diaphragm pathology associated with CMV. METHODS: Sprague-Dawley rats were randomly assigned to one of the following five groups:1) control (no mechanical ventilation); 2) 12 hrs of controlled mechanical ventilation (12CMV); 3) 18 hrs of controlled mechanical ventilation (18CMV); 4) 12 hrs of pressure support ventilation (12PSV); or 5) 18 hrs of pressure support ventilation (18PSV). MEASUREMENTS AND MAIN RESULTS: We carried out the following measurements on diaphragm specimens: 4-hydroxynonenal-a marker of oxidative stress, active caspase-3 (casp-3), active calpain-1 (calp-1), fiber type cross-sectional area, and specific force (sp F). Compared with the control, both 12PSV and 18PSV promoted a significant decrement in diaphragmatic specific force production, but to a lesser degree than 12CMV and 18CMV. Furthermore, 12CMV, 18PSV, and 18CMV resulted in significant atrophy in all diaphragm fiber types as well as significant increases in a biomarker of oxidative stress (4-hydroxynonenal) and increased proteolytic activity (20S proteasome, calpain-1, and caspase-3). Furthermore, although no inspiratory effort occurs during controlled mechanical ventilation, it was observed that pressure support ventilation resulted in large decrement, approximately 96%, in inspiratory effort compared with spontaneously breathing animals. CONCLUSIONS: High levels of prolonged pressure support ventilation promote diaphragmatic atrophy and contractile dysfunction. Furthermore, similar to controlled mechanical ventilation, pressure support ventilation-induced diaphragmatic atrophy and weakness are associated with both diaphragmatic oxidative stress and protease activation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mechanisms of disuse muscle atrophy: role of oxidative stress
Powers, S. K., Kavazis, A. N., & DeRuisseau, K. C. (2005) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00469.2004 · Cited by 368
Self-citationDodson, S., Baracos, V. E., Jatoi, A., Evans, W. J., Cella, D., Dalton, J. T., & Steiner, M. S. (2011) · Annual Review of Medicine · doi:10.1146/annurev-med-061509-131248 · Cited by 319
Cited by
Evolution of Diaphragm Thickness during Mechanical Ventilation. Impact of Inspiratory Effort
Goligher, E. C., Fan, E., Herridge, M. S., Murray, A., Vorona, S., Brace, D., Rittayamai, N., Lanys, A., Tomlinson, G., Singh, J. M., et al. (2015) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201503-0620oc · Cited by 608
Matamis, D., Soilemezi, E., Tsagourias, M., Akoumianaki, E., Dimassi, S., Boroli, F., Richard, J.-C. M., & Brochard, L. (2013) · Intensive Care Medicine · doi:10.1007/s00134-013-2823-1 · Cited by 576
Diaphragm ultrasound as a predictor of successful extubation from mechanical ventilation
DiNino, E., Gartman, E. J., Sethi, J. M., & McCool, F. D. (2014) · Thorax · doi:10.1136/thoraxjnl-2013-204111 · Cited by 487
Lung- and Diaphragm-Protective Ventilation
Goligher, E. C., Dres, M., Patel, B. K., Sahetya, S. K., Beitler, J. R., Telias, I., Yoshida, T., Vaporidi, K., Grieco, D. L., Schepens, T., et al. (2020) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.202003-0655cp · Cited by 411
Impact of prolonged assisted ventilation on diaphragmatic efficiency: NAVA versus PSV
Di mussi, R., Spadaro, S., Mirabella, L., Volta, C. A., Serio, G., Staffieri, F., Dambrosio, M., Cinnella, G., Bruno, F., & Grasso, S. (2016) · Critical Care · doi:10.1186/s13054-015-1178-0 · Cited by 404
Mechanical Ventilation: State of the Art
Pham, T., Brochard, L. J., & Slutsky, A. S. (2017) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2017.05.004 · Cited by 377
Umbrello, M., Formenti, P., Longhi, D., Galimberti, A., Piva, I., Pezzi, A., Mistraletti, G., Marini, J. J., & Iapichino, G. (2015) · Critical Care · doi:10.1186/s13054-015-0894-9 · Cited by 343
Goligher, E. C., Brochard, L. J., Reid, W. D., Fan, E., Saarela, O., Slutsky, A. S., Kavanagh, B. P., Rubenfeld, G. D., & Ferguson, N. D. (2019) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(18)30366-7 · Cited by 275
Respiratory Drive in Critically Ill Patients. Pathophysiology and Clinical Implications
Vaporidi, K., Akoumianaki, E., Telias, I., Goligher, E. C., Brochard, L., & Georgopoulos, D. (2020) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201903-0596so · Cited by 267
Diaphragm weakness in mechanically ventilated critically ill patients
Supinski, G. S., & Ann Callahan, L. (2013) · Critical Care · doi:10.1186/cc12792 · Cited by 265
Farghaly, S., & Hasan, A. A. (2017) · Australian Critical Care · doi:10.1016/j.aucc.2016.03.004 · Cited by 159
Hudson, M. B., Woodworth-Hobbs, M. E., Zheng, B., Rahnert, J. A., Blount, M. A., Gooch, J. L., Searles, C. D., & Price, S. R. (2014) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00266.2013 · Cited by 137
Self-citation
Metadata
- Authors
- Hudson, M. B., Smuder, A. J., Nelson, W. B., Bruells, C. S., Levine, S., & Powers, S. K.
- Venue
- Critical Care Medicine
- Published
- 2012-04
- Volume
- 40
- Issue
- 4
- Pages
- 1254-1260
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2072650866
- Cited by
- 205
- References
- 2
- FWCI
- 14.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.