The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Spontaneous breathing during lung-protective ventilation in an experimental acute lung injury model: High transpulmonary pressure associated with strong spontaneous breathing effort may worsen lung injury*
Open accessAbstract
OBJECTIVE: We investigated whether potentially injurious transpulmonary pressure could be generated by strong spontaneous breathing and exacerbate lung injury even when plateau pressure is limited to <30 cm H2O. DESIGN: Prospective, randomized, animal study. SETTING: University animal research laboratory. SUBJECTS: Thirty-two New Zealand White rabbits. INTERVENTIONS: Lavage-injured rabbits were randomly allocated to four groups to receive low or moderate tidal volume ventilation, each combined with weak or strong spontaneous breathing effort. Inspiratory pressure for low tidal volume ventilation was set at 10 cm H2O and tidal volume at 6 mL/kg. For moderate tidal volume ventilation, the values were 20 cm H2O and 7-9 mL/kg. The groups were: low tidal volume ventilation+spontaneous breathingweak, low tidal volume ventilation+spontaneous breathingstrong, moderate tidal volume ventilation+spontaneous breathingweak, and moderate tidal volume ventilation+spontaneous breathingstrong. Each group had the same settings for positive end-expiratory pressure of 8 cm H2O. MEASUREMENTS AND RESULTS: Respiratory variables were measured every 60 mins. Distribution of lung aeration and alveolar collapse were histologically evaluated. Low tidal volume ventilation+spontaneous breathingstrong showed the most favorable oxygenation and compliance of respiratory system, and the best lung aeration. By contrast, in moderate tidal volume ventilation+spontaneous breathingstrong, the greatest atelectasis with numerous neutrophils was observed. While we applied settings to maintain plateau pressure at <30 cm H2O in all groups, in moderate tidal volume ventilation+spontaneous breathingstrong, transpulmonary pressure rose >33 cm H2O. Both minute ventilation and respiratory rate were higher in the strong spontaneous breathing groups. CONCLUSIONS: Even when plateau pressure is limited to <30 cm H2O, combined with increased respiratory rate and tidal volume, high transpulmonary pressure generated by strong spontaneous breathing effort can worsen lung injury. When spontaneous breathing is preserved during mechanical ventilation, transpulmonary pressure and tidal volume should be strictly controlled to prevent further lung injury.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuromuscular Blockers in Early Acute Respiratory Distress Syndrome
Papazian, L., Forel, J.-M., Gacouin, A., Penot-Ragon, C., Perrin, G., Loundou, A., Jaber, S., Arnal, J.-M., Perez, D., Seghboyan, J.-M., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1005372 · Cited by 2,432 · cited 2×
“Considering that the placebo group had a higher incidence of barotrauma even when Pplat was similar to the neuromuscular blocking agent group, some of the benefits of neuromuscular blocking agent use might derive from limitation of total alveolar stretching pressure and better synchrony by preventing SB effort (19, 20…”
BackgroundResultPUTENSEN, C., ZECH, S., WRIGGE, H., ZINSERLING, J., STÜBER, F., VON SPIEGEL, T., & MUTZ, N. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.1.2001078 · Cited by 638
Forel, J.-M., Roch, A., Marin, V., Michelet, P., Demory, D., Blache, J.-L., Perrin, G., Gainnier, M., Bongrand, P., & Papazian, L. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000239435.87433.0d · Cited by 400
Hypercapnic Acidosis Is Protective in an In Vivo Model of Ventilator-induced Lung Injury
Sinclair, S. E., Kregenow, D. A., Lamm, W. J. E., Starr, I. R., Chi, E. Y., & Hlastala, M. P. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200112-117oc · Cited by 230
Neuromuscular Blocking Agents in ARDS
Slutsky, A. S. (2010) · New England Journal of Medicine · doi:10.1056/nejme1007136 · Cited by 202
Clinical review: respiratory mechanics in spontaneous and assisted ventilation.
Grinnan, D., & Truwit, J. D. (2005) · Critical Care · doi:10.1186/cc3516 · Cited by 199
Imai, Y., Nakagawa, S., Ito, Y., Kawano, T., Slutsky, A. S., & Miyasaka, K. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.4.1836 · Cited by 170
P0.1 is a useful parameter in setting the level of pressure support ventilation
Alberti, A., Gallo, F., Fongaro, A., Valenti, S., & Rossi, A. (1995) · Intensive Care Medicine · doi:10.1007/bf01700158 · Cited by 148
Putensen, C., Rasanen, J. O., & López, F. A. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.150.1.8025733 · Cited by 132
Comparison of lung protective ventilation strategies in a rabbit model of acute lung injury
Rotta, A. T., Gunnarsson, B., Fuhrman, B. P., Hernan, L. J., & Steinhorn, D. M. (2001) · Critical Care Medicine · doi:10.1097/00003246-200111000-00021 · Cited by 123
Grasso, F., Engelberts, D., Helm, E. J., Frndova, H., Jarvis, S., Talakoub, O., McKerlie, C., Babyn, P., Post, M., & Kavanagh, B. P. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200707-1004oc · Cited by 90
Vaporidi, K., Voloudakis, G., Prinianakis, G., Kondili, Ε., Koutsopoulos, A. V., Tsatsanis, C., & Georgopoulos, D. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e318169f30e · Cited by 83
Saddy, F., Oliveira, G. P., Garcia, C. S. N. B., Nardelli, L. M., Rzezinski, A. F., Ornellas, D. S., Morales, M. M., Capelozzi, V. L., Pelosi, P. P., & Rocco, P. R. M. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-1808-6 · Cited by 54
Varelmann, D. J., Muders, T., Zinserling, J., Guenther, U., Magnusson, A., Hedenstierna, G., Putensen, C., & Wrigge, H. (2008) · Critical Care · doi:10.1186/cc7108 · Cited by 21
Cited by
Official ERS/ATS clinical practice guidelines: noninvasive ventilation for acute respiratory failure
Rochwerg, B., Brochard, L., Elliott, M. W., Hess, D., Hill, N. S., Nava, S., Navalesi, P., Antonelli, M., Brozek, J., Conti, G., et al. (2017) · European Respiratory Journal · doi:10.1183/13993003.02426-2016 · Cited by 1,668
Fan, E., Del Sorbo, L., Goligher, E. C., Hodgson, C. L., Munshi, L., Walkey, A. J., Adhikari, N. K. J., Amato, M. B. P., Branson, R., Brower, R. G., et al. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201703-0548st · Cited by 1,630
Mechanical Ventilation to Minimize Progression of Lung Injury in Acute Respiratory Failure
Brochard, L., Slutsky, A., & Pesenti, A. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201605-1081cp · Cited by 1,274
Spontaneous Effort Causes Occult Pendelluft during Mechanical Ventilation
Yoshida, T., Torsani, V., Gomes, S., De Santis, R. R., Beraldo, M. A., Costa, E. L. V., Tucci, M. R., Zin, W. A., Kavanagh, B. P., & Amato, M. B. P. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201303-0539oc · Cited by 575
Self-citationCarteaux, G., Millán-Guilarte, T., De Prost, N., Razazi, K., Abid, S., Thille, A. W., Schortgen, F., Brochard, L., Brun-Buisson, C., & Mekontso Dessap, A. (2016) · Critical Care Medicine · doi:10.1097/ccm.0000000000001379 · Cited by 491
Metadata
- Authors
- Yoshida, T., Uchiyama, A., Matsuura, N., Mashimo, T., & Fujino, Y.
- Venue
- Critical Care Medicine
- Published
- 2012-05
- Volume
- 40
- Issue
- 5
- Pages
- 1578-1585
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2090838762
- Cited by
- 312
- References
- 14
- FWCI
- 8.77
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.