The DOI matches its Crossref record.
Effects of norepinephrine on mean systemic pressure and venous return in human septic shock*
Abstract
OBJECTIVES: Norepinephrine exerts venoconstriction that could increase both the mean systemic pressure and the resistance to venous return, but this has not yet been investigated in human septic shock. We examined the relative importance of both effects and the resulting effect on venous return when decreasing the dose of norepinephrine. SETTING: Intensive care unit. PATIENTS: Sixteen septic shock patients. MEASUREMENTS: For estimating the venous return curve, we constructed the regression line between the pairs of cardiac index (pulse contour analysis) and central venous pressure values. These values were measured during 15-sec end-inspiratory and end-expiratory ventilatory occlusions performed at two levels of positive end-expiratory pressure, in view of widening the range of cardiac index:central venous pressure measurements and increasing the accuracy of the regression line. The x-axis intercept of the regression line was used to estimate the mean systemic pressure and the inverse of the slope of the regression line to quantify resistance to venous return. These measurements were obtained before and after decreasing the dose of norepinephrine. Passive leg raising was performed before and after decreasing the dose of norepinephrine. MAIN RESULTS: Decreasing the dose of norepinephrine from 0.30 (0.10-1.40) to 0.19 (0.08-1.15) µg/kg/min decreased the mean systemic pressure from 33 ± 12 mm Hg to 26 ± 10 mm Hg (p = .0003). The slope of the multipoint cardiac index:central venous pressure relationship increased (p = .02). The resistance to venous return decreased, i.e., 1/slope decreased. Simultaneously, cardiac index decreased from 3.47 ± 0.86 L/min/m2 to 3.28 ± 0.76 L/min/m (p = .04), indicating a decrease in venous return. Passive leg raising increased cardiac index to a larger extent after (8% ± 4%) than before (1% ± 4%) decreasing norepinephrine (p = .001), suggesting an increase in unstressed blood volume at the lowest dose of norepinephrine. CONCLUSIONS: In septic shock patients, decreasing the dose of norepinephrine decreased the mean systemic pressure and, to a lesser extent, the resistance to venous return. As a result, venous return decreased.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
How can assessing hemodynamics help to assess volume status?
De Backer, D., Aissaoui, N., Cecconi, M., Chew, M. S., Denault, A., Hajjar, L., Hernandez, G., Messina, A., Myatra, S. N., Ostermann, M., et al. (2022) · Intensive Care Medicine · doi:10.1007/s00134-022-06808-9 · Cited by 199
Self-citationThe initial resuscitation of septic shock
Cinel, I., Kasapoglu, U. S., Gul, F., & Dellinger, R. P. (2020) · Journal of Critical Care · doi:10.1016/j.jcrc.2020.02.004 · Cited by 69
Metadata
- Authors
- Persichini, R., Silva, S., Teboul, J.-L., Jozwiak, M., Chemla, D., Richard, C., & Monnet, X.
- Venue
- Critical Care Medicine
- Published
- 2012-12
- Volume
- 40
- Issue
- 12
- Pages
- 3146-3153
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2074693408
- Cited by
- 218
- References
- 0
- FWCI
- 9.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of norepinephrine on mean systemic pressure and venous return in human septic shock*. https://app.cochat.ai/papers/10.1097/ccm.0b013e318260c6c3
- The paper
- Persichini, R., Silva, S., Teboul, J.-L., Jozwiak, M., Chemla, D., Richard, C., & Monnet, X. (2012). Effects of norepinephrine on mean systemic pressure and venous return in human septic shock*. Critical Care Medicine. https://doi.org/10.1097/ccm.0b013e318260c6c3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.