CoChat

Effects of norepinephrine on mean systemic pressure and venous return in human septic shock*

Persichini, Romain, Silva, Serena, Teboul, Jean-Louis, Jozwiak, Mathieu, Chemla, Denis, Richard, Christian, Monnet, Xavier · 2012 · Critical Care Medicine
Cited by 218

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: Norepinephrine exerts venoconstriction that could increase both the mean systemic pressure and the resistance to venous return, but this has not yet been investigated in human septic shock. We examined the relative importance of both effects and the resulting effect on venous return when decreasing the dose of norepinephrine. SETTING: Intensive care unit. PATIENTS: Sixteen septic shock patients. MEASUREMENTS: For estimating the venous return curve, we constructed the regression line between the pairs of cardiac index (pulse contour analysis) and central venous pressure values. These values were measured during 15-sec end-inspiratory and end-expiratory ventilatory occlusions performed at two levels of positive end-expiratory pressure, in view of widening the range of cardiac index:central venous pressure measurements and increasing the accuracy of the regression line. The x-axis intercept of the regression line was used to estimate the mean systemic pressure and the inverse of the slope of the regression line to quantify resistance to venous return. These measurements were obtained before and after decreasing the dose of norepinephrine. Passive leg raising was performed before and after decreasing the dose of norepinephrine. MAIN RESULTS: Decreasing the dose of norepinephrine from 0.30 (0.10-1.40) to 0.19 (0.08-1.15) µg/kg/min decreased the mean systemic pressure from 33 ± 12 mm Hg to 26 ± 10 mm Hg (p = .0003). The slope of the multipoint cardiac index:central venous pressure relationship increased (p = .02). The resistance to venous return decreased, i.e., 1/slope decreased. Simultaneously, cardiac index decreased from 3.47 ± 0.86 L/min/m2 to 3.28 ± 0.76 L/min/m (p = .04), indicating a decrease in venous return. Passive leg raising increased cardiac index to a larger extent after (8% ± 4%) than before (1% ± 4%) decreasing norepinephrine (p = .001), suggesting an increase in unstressed blood volume at the lowest dose of norepinephrine. CONCLUSIONS: In septic shock patients, decreasing the dose of norepinephrine decreased the mean systemic pressure and, to a lesser extent, the resistance to venous return. As a result, venous return decreased.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e318260c6c3

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

Metadata

Authors
Persichini, R., Silva, S., Teboul, J.-L., Jozwiak, M., Chemla, D., Richard, C., & Monnet, X.
Venue
Critical Care Medicine
Published
2012-12
Volume
40
Issue
12
Pages
3146-3153
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2074693408
Cited by
218
References
20
FWCI
9.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.