An Electronic Simplified Acute Physiology Score-Based Risk Adjustment Score for Critical Illness in an Integrated Healthcare System*
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Risk adjustment is essential in evaluating the performance of an ICU; however, assigning scores is time-consuming. We sought to create an automated ICU risk adjustment score, based on the Simplified Acute Physiology Score 3, using only data available within the electronic medical record (Kaiser Permanente HealthConnect). DESIGN, SETTING, AND PATIENTS: The eSimplified Acute Physiology Score 3 was developed by adapting Kaiser Permanente HealthConnect structured data to Simplified Acute Physiology Score 3 criteria. The model was tested among 67,889 first-time ICU admissions at 21 hospitals between 2007 and 2011 to predict hospital mortality. Model performance was evaluated using published Simplified Acute Physiology Score 3 global and North American coefficients; a first-level customized version of the eSimplified Acute Physiology Score 3 was also developed in a 40% derivation cohort and tested in a 60% validation cohort. MEASUREMENTS: Electronic variables were considered "directly" available if they could be mapped exactly within Kaiser Permanente HealthConnect; they were considered "adapted" if no exact electronic corollary was identified. Model discrimination was evaluated with area under receiver operating characteristic curves; calibration was assessed using Hosmer-Lemeshow goodness-of-fit tests. MAIN RESULTS: Mean age at ICU admission was 65 ± 17 yrs. Mortality in the ICU was 6.2%; total in-hospital mortality was 11.2%. The majority of Simplified Acute Physiology Score 3 variables were considered "directly" available; others required adaptation based on diagnosis coding, medication records, or procedure tables. Mean eSimplified Acute Physiology Score 3 scores were 45 ± 13. Using published Simplified Acute Physiology Score 3 global and North American coefficients, the eSimplified Acute Physiology Score 3 demonstrated good discrimination (area under the receiver operating characteristic curve, 0.80-0.81); however, it overpredicted mortality. The customized eSimplified Acute Physiology Score 3 score demonstrated good discrimination (area under the receiver operating characteristic curve, 0.82) and calibration (Hosmer-Lemeshow goodness-of-fit chi-square p = 0.57) in the validation cohort. The eSimplified Acute Physiology Score 3 demonstrated stable performance when cohorts were limited to specific hospitals and years. CONCLUSIONS: The customized eSimplified Acute Physiology Score 3 shows good potential for providing automated risk adjustment in the intensive care unit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A REVIEW OF GOODNESS OF FIT STATISTICS FOR USE IN THE DEVELOPMENT OF LOGISTIC REGRESSION MODELS1
LEMESHOW, S., & HOSMER, D. W. (1982) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a113284 · Cited by 1,947
Saeed, M., Villarroel, M., Reisner, A. T., Clifford, G., Lehman, L.-W., Moody, G., Heldt, T., Kyaw, T. H., Moody, B., & Mark, R. G. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e31820a92c6 · Cited by 1,162
Kramer, A. A., & Zimmerman, J. E. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000275267.64078.b0 · Cited by 886
Clinical review: Scoring systems in the critically ill
Vincent, J.-L., & Moreno, R. (2010) · Critical Care · doi:10.1186/cc8204 · Cited by 634
Assessing the level of healthcare information technology adoption in the United States: a snapshot
Poon, E. G., Jha, A. K., Christino, M., Honour, M. M., Fernandopulle, R., Middleton, B., Newhouse, J., Leape, L., Bates, D. W., Blumenthal, D., et al. (2006) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-6-1 · Cited by 318
Liu, V., Kipnis, P., Gould, M. K., & Escobar, G. J. (2010) · Medical Care · doi:10.1097/mlr.0b013e3181e359f3 · Cited by 87
Self-citation
Cited by
A randomized trial of a family-support intervention in intensive care units
White, D. B., Angus, D. C., Shields, A.-M., Buddadhumaruk, P., Pidro, C., Paner, C., Chaitin, E., Chang, C.-C. H., Pike, F., Weissfeld, L., et al. (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1802637 · Cited by 524
Delahanty, R. J., Kaufman, D., & Jones, S. S. (2018) · Critical Care Medicine · doi:10.1097/ccm.0000000000003011 · Cited by 105
“First, although the underlying algorithms for APACHE-IV and MPM 0 -III are in the public domain and avail- able at no cost, to use these tools in practice typically requires the payment of licensing, implementation, and maintenance fees which may be cost prohibitive for many hospitals.”
BackgroundMethodInfluentialHu, C.-A., Chen, C.-M., Fang, Y.-C., Liang, S.-J., Wang, H.-C., Fang, W.-F., Sheu, C.-C., Perng, W.-C., Yang, K.-Y., Kao, K.-C., et al. (2020) · BMJ Open · doi:10.1136/bmjopen-2019-033898 · Cited by 106
“18 19 However, the lack of intuitional understanding of ML models is one of the main obstacles in the implementation of ML in the medical field.”
Background
Metadata
- Authors
- Liu, V., Turk, B. J., Ragins, A. I., Kipnis, P., & Escobar, G. J.
- Venue
- Critical Care Medicine
- Published
- 2013-01
- Volume
- 41
- Issue
- 1
- Pages
- 41-48
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W1965832089
- Cited by
- 46
- References
- 6
- FWCI
- 2.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Electronic Simplified Acute Physiology Score-Based Risk Adjustment Score for Critical Illness in an Integrated Healthcare System*. https://app.cochat.ai/papers/10.1097/ccm.0b013e318267636e
- The paper
- Liu, V., Turk, B. J., Ragins, A. I., Kipnis, P., & Escobar, G. J. (2013). An Electronic Simplified Acute Physiology Score-Based Risk Adjustment Score for Critical Illness in an Integrated Healthcare System*. Critical Care Medicine. https://doi.org/10.1097/ccm.0b013e318267636e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.