Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 302

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Lung Stress and Strain During Mechanical Ventilation: Any Difference Between Statics and Dynamics?*

Protti, Alessandro, Andreis, Davide T., Monti, Massimo, Santini, Alessandro, Sparacino, Cristina C., Langer, Thomas, Votta, Emiliano, Gatti, Stefano, Lombardi, Luciano, Leopardi, Orazio, Masson, Serge, Cressoni, Massimo, Gattinoni, Luciano·2013·Critical Care Medicine

Abstract

OBJECTIVE: Tidal volume (VT) and volume of gas caused by positive end-expiratory pressure (VPEEP) generate dynamic and static lung strains, respectively. Our aim was to clarify whether different combinations of dynamic and static strains, resulting in the same large global strain, constantly produce lung edema. DESIGN: Laboratory investigation. SETTING: Animal unit. SUBJECTS: Twenty-eight healthy pigs. INTERVENTIONS: After lung computed tomography, 20 animals were ventilated for 54 hours at a global strain of 2.5, either entirely dynamic (VT 100% and VPEEP 0%), partly dynamic and partly static (VT 75-50% and VPEEP 25-50%), or mainly static (VT 25% and VPEEP 75%) and then killed. In eight other pigs (VT 25% and VPEEP 75%), VPEEP was abruptly zeroed after 36-54 hours and ventilation continued for 3 hours. MEASUREMENTS AND MAIN RESULTS: Edema was diagnosed when final lung weight (balance) exceeded the initial weight (computed tomography). Mortality, lung mechanics, gas exchange, pulmonary histology, and inflammation were evaluated. All animals ventilated with entirely dynamic strain (VT 825±424 mL) developed pulmonary edema (lung weight from 334±38 to 658±99 g, p<0.01), whereas none of those ventilated with mainly static strain (VT 237±21 mL and VPEEP 906±114 mL, corresponding to 19±1 cm H2O of positive end-expiratory pressure) did (from 314±55 to 277±46 g, p=0.65). Animals ventilated with intermediate combinations finally had normal or largely increased lung weight. Smaller dynamic and larger static strains lowered mortality (p<0.01), derangement of lung mechanics (p<0.01), and arterial oxygenation (p<0.01), histological injury score (p=0.03), and bronchoalveolar interleukin-6 concentration (p<0.01). Removal of positive end-expiratory pressure did not result in abrupt increase in lung weight (from 336±36 to 351±77 g, p=0.51). CONCLUSIONS: Lung edema forms (possibly as an all-or-none response) depending not only on global strain but also on its components. Large static are less harmful than large dynamic strains, but not because the former merely counteracts fluid extravasation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e31827417a6

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 30 references

Cited by

See all 302

Metadata

Authors
Protti, A., Andreis, D. T., Monti, M., Santini, A., Sparacino, C. C., Langer, T., Votta, E., Gatti, S., Lombardi, L., Leopardi, O., Masson, S., Cressoni, M., & Gattinoni, L.
Venue
Critical Care Medicine
Published
2013-04
Volume
41
Issue
4
Pages
1046-1055
ISSN
0090-3493 (ISSN-L)
OpenAlex
W1995928834
Cited by
302
References
30
FWCI
18.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Lung Stress and Strain During Mechanical Ventilation: Any Difference Between Statics and Dynamics?*. https://app.cochat.ai/papers/10.1097/ccm.0b013e31827417a6
The paper
Protti, A., Andreis, D. T., Monti, M., Santini, A., Sparacino, C. C., Langer, T., Votta, E., Gatti, S., Lombardi, L., Leopardi, O., Masson, S., Cressoni, M., & Gattinoni, L. (2013). Lung Stress and Strain During Mechanical Ventilation: Any Difference Between Statics and Dynamics?*. Critical Care Medicine. https://doi.org/10.1097/ccm.0b013e31827417a6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.