The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Lactate and Venoarterial Carbon Dioxide Difference/Arterial-Venous Oxygen Difference Ratio, but Not Central Venous Oxygen Saturation, Predict Increase in Oxygen Consumption in Fluid Responders*
Abstract
OBJECTIVES: During circulatory failure, the ultimate goal of treatments that increase cardiac output is to reduce tissue hypoxia. This can only occur if oxygen consumption depends on oxygen delivery. We compared the ability of central venous oxygen saturation and markers of anaerobic metabolism to predict whether a fluid-induced increase in oxygen delivery results in an increase in oxygen consumption. DESIGN: Prospective study. SETTING: ICU. PATIENTS: Fifty-one patients with an acute circulatory failure (78% of septic origin). MEASUREMENTS: Before and after a volume expansion (500 mL of saline), we measured cardiac index, o2- and Co2-derived variables and lactate. MAIN RESULTS: Volume expansion increased cardiac index ≥ 15% in 49% of patients ("volume-responders"). Oxygen delivery significantly increased in these 25 patients (+32% ± 16%, p < 0.0001). An increase in oxygen consumption ≥ 15% concomitantly occurred in 56% of these 25 volume-responders (+38% ± 28%). Compared with the volume-responders in whom oxygen consumption did not increase, the volume-responders in whom oxygen consumption increased ≥ 15% were characterized by a higher lactate (2.3 ± 1.1 mmol/L vs. 5.5 ± 4.0 mmol/L, respectively) and a higher ratio of the veno-arterial carbon dioxide tension difference (P(v - a)Co2) over the arteriovenous oxygen content difference (C(a - v)o2). A fluid-induced increase in oxygen consumption greater than or equal to 15% was not predicted by baseline central venous oxygen saturation but by high baseline lactate and (P(v - a)Co2/C(a - v)o2 ratio (areas under the receiving operating characteristics curves: 0.68 ± 0.11, 0.94 ± 0.05, and 0.91 ± 0.06). In volume-nonresponders, volume expansion did not significantly change cardiac index, but the oxygen delivery decreased due to a hemodilution-induced decrease in hematocrit. CONCLUSIONS: In volume-responders, unlike markers of anaerobic metabolism, central venous oxygen saturation did not allow the prediction of whether a fluid-induced increase in oxygen delivery would result in an increase in oxygen consumption. This suggests that along with indicators of volume-responsiveness, the indicators of anaerobic metabolism should be considered instead of central venous oxygen saturation for starting hemodynamic resuscitation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Early goal-directed therapy in the treatment of severe sepsis and septic shock
Rivers, E., Nguyen, B., Havstad, S., Ressler, J., Muzzin, A., Knoblich, B., Peterson, E., & Tomlanovich, M. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010307 · Cited by 10,743
Surviving Sepsis Campaign: International Guidelines for Management of Severe Sepsis and Septic Shock
Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., Jaeschke, R., et al. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31827e83af · Cited by 9,694
The Surviving Sepsis Campaign Guidelines Committee including The Pediatric Subgroup*, Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., et al. (2013) · Intensive Care Medicine · doi:10.1007/s00134-012-2769-8 · Cited by 7,290
Oxygen-Derived Free Radicals in Postischemic Tissue Injury
Epstein, F. H., & McCord, J. M. (1985) · New England Journal of Medicine · doi:10.1056/nejm198501173120305 · Cited by 5,399
Marik, P. E., Cavallazzi, R., Vasu, T., & Hirani, A. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a590da · Cited by 1,272
Jones, A. E. (2010) · JAMA · doi:10.1001/jama.2010.158 · Cited by 1,077
Jansen, T. C., van Bommel, J., Schoonderbeek, F. J., Sleeswijk Visser, S. J., van der Klooster, J. M., Lima, A. P., Willemsen, S. P., & Bakker, J. (2010) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200912-1918oc · Cited by 894
Bakker, J., Gris, P., Coffernils, M., Kahn, R. J., & Vincent, J.-L. (1996) · The American Journal of Surgery · doi:10.1016/s0002-9610(97)89552-9 · Cited by 851
Hemodynamic parameters to guide fluid therapy
Marik, P. E., Monnet, X., & Teboul, J.-L. (2011) · Annals of Intensive Care · doi:10.1186/2110-5820-1-1 · Cited by 686
Self-citationBihari, D., Smithies, M., Gimson, A., & Tinker, J. (1987) · New England Journal of Medicine · doi:10.1056/nejm198708133170701 · Cited by 554
Lactate is an unreliable indicator of tissue hypoxia in injury or sepsis
James, J. H., Luchette, F. A., McCarter, F. D., & Fischer, J. E. (1999) · The Lancet · doi:10.1016/s0140-6736(98)91132-1 · Cited by 538
Vincent, J.-L., & Weil, M. H. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000214677.76535.a5 · Cited by 424
Lactate and shock state: The metabolic view.
Levy, B. (2006) · Current Opinion in Critical Care · doi:10.1097/01.ccx.0000235208.77450.15 · Cited by 422
Implementation and outcomes of the Multiple Urgent Sepsis Therapies (MUST) protocol*
Shapiro, N. I., Howell, M. D., Talmor, D., Lahey, D., Ngo, L., Buras, J., Wolfe, R. E., Weiss, J. W., & Lisbon, A. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000206104.18647.a8 · Cited by 348
The concept of a critical oxygen delivery
Schumacker, P. T., & Cain, S. M. (1987) · Intensive Care Medicine · doi:10.1007/bf00265110 · Cited by 336
Vallée, F., Vallet, B., Mathe, O., Parraguette, J., Mari, A., Silva, S., Samii, K., Fourcade, O., & Genestal, M. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1199-0 · Cited by 273
Mekontso-Dessap, A., Castelain, V., Anguel, N., Bahloul, M., Schauvliege, F., Richard, C., & Teboul, J.-L. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1215-8 · Cited by 245
Self-citationLet us use the pulmonary artery catheter correctly and only when we need it
Pinsky, M. R., & Vincent, J.-L. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000163238.64905.56 · Cited by 189
Measurements of Right Ventricular Volumes during Fluid Challenge
Reuse, C., Vincent, J.-L., & Pinsky, M. R. (1990) · Chest · doi:10.1378/chest.98.6.1450 · Cited by 175
Clinical review: use of venous oxygen saturations as a goal - a yet unfinished puzzle
van Beest, P., Wietasch, G. J. K. G., Scheeren, T., Spronk, P. E., & Kuiper, M. A. (2011) · Critical Care · doi:10.1186/cc10351 · Cited by 148
Lactic acidosis in sepsis: a commentary
Gutiérrez, G., & Wulf-Gutierrez, M. E. (1996) · Intensive Care Medicine · doi:10.1007/bf01728325 · Cited by 142
Oxygen transport—the oxygen delivery controversy
Vincent, J., & Backer, D. D. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2384-4 · Cited by 128
van Beest, P. A., Hofstra, J. J., Schultz, M. J., Boerma, E. C., Spronk, P. E., & Kuiper, M. A. (2008) · Critical Care · doi:10.1186/cc6811 · Cited by 117
Perz, S., Uhlig, T., Kohl, M., Bredle, D. L., Reinhart, K., Bauer, M. W., & Kortgen, A. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-1980-8 · Cited by 109
Perel, A. (2008) · Critical Care · doi:10.1186/cc6979 · Cited by 86
Mathematical Coupling Explains Dependence of Oxygen Consumption on Oxygen Delivery in ARDS
Phang, P. T., Cunningham, K., Ronco, J. J., Wiggs, B. R., & Russell, J. A. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.150.2.8049809 · Cited by 85
Anaerobic CO2 production by dog kidney in vitro
Hm, R., & Cohen, J. (1966) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1966.211.2.493 · Cited by 80
Association of physical examination with pulmonary artery catheter parameters in acute lung injury *
Grissom, C. K., Morris, A. H., Lanken, P. N., Ancukiewicz, M., Orme, J. F., Schoenfeld, D., & Thompson, B. (2009) · Critical Care Medicine · doi:10.1097/00003246-200910000-00007 · Cited by 57
Teboul, J., Graïni, L., Boujdaria, R., Berton, C., & Richard, C. (1993) · CHEST Journal · doi:10.1378/chest.103.1.81 · Cited by 47
Self-citation
Cited by
Cecconi, M., De Backer, D., Antonelli, M., Beale, R., Bakker, J., Hofer, C., Jaeschke, R., Mebazaa, A., Pinsky, M. R., Teboul, J. L., et al. (2014) · Intensive Care Medicine · doi:10.1007/s00134-014-3525-z · Cited by 1,767
Self-citationTaiana, M., Tomasella, I., Russo, A., Lerose, A., Graziadei, M. C., Corubolo, L., Rama, J., Schweiger, V., Vignola, A., Polati, E., et al. (2023) · doi:10.20944/preprints202308.1985.v1 · Cited by 6
Metadata
- Authors
- Monnet, X., Julien, F., Ait-Hamou, N., Lequoy, M., Gosset, C., Jozwiak, M., Persichini, R., Anguel, N., Richard, C., & Teboul, J.-L.
- Venue
- Critical Care Medicine
- Published
- 2013-06
- Volume
- 41
- Issue
- 6
- Pages
- 1412-1420
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2139351862
- Cited by
- 255
- References
- 29
- FWCI
- 12.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.