Pharmacokinetics of Cocaine and Metabolites in Human Oral Fluid and Correlation With Plasma Concentrations After Controlled Administration
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
UNLABELLED: Oral fluid is an attractive alternative matrix for drug testing with a noninvasive and directly observed collection, but there are few controlled cocaine administration studies to guide interpretation. MATERIALS AND METHODS: While residing on a closed research unit for up to 10 weeks under constant medical supervision, 19 participants were administered 75 mg/70 kg subcutaneous cocaine and 14 received 150 mg/70 kg. The disposition of cocaine, benzoylecgonine (BE), and ecgonine methyl ester (EME) into oral fluid was determined by gas chromatography-mass spectrometry for 0.08 to 48 hours after administration. RESULTS: In oral fluid collected by citric acid candy-stimulated expectoration, cocaine first appeared in oral fluid 0.08 to 0.32 hours after dosing and was rapidly eliminated with half-lives of 1.1 to 3.8 hours. BE and EME were first detected 0.08 to 1.0 hours after dosing with longer half-lives of 3.4 to 13.8 (BE) and 2.4 to 15.5 hours (EME) (P < 0.05). Oral fluid and plasma concentrations were significantly correlated for cocaine, BE, and EME (P < 0.0001). There were no significant differences (P > 0.05) in first and last detection times with the 8-μg/L cutoff proposed by the Substance Abuse and Mental Health Services Administration or the 10-μg/L cutoff from the European initiative, Driving Under the Influence of Drugs, Alcohol and Medicines. Metabolite:cocaine ratios increased after cocaine administration, potentially helpful for interpreting time of last use. Comparison of oral fluid collection through citric acid candy-stimulated expectoration, citric acid-treated Salivette, and neutral cotton Salivette devices did not reveal significant differences between devices for areas under the curve for cocaine, BE, or EME (P > 0.05). DISCUSSION AND CONCLUSION: These results provide additional evidence for interpreting cocaine and metabolite concentrations in oral fluid and oral fluid's usefulness as an alternative matrix for drug testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oral fluid testing for drugs of abuse
Bosker, W. M., & Huestis, M. A. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.108670 · Cited by 378
Self-citationOral fluid collection: the neglected variable in oral fluid testing
Crouch, D. J. (2005) · Forensic Science International · doi:10.1016/j.forsciint.2005.02.028 · Cited by 228 · cited 2×
“Passage of drugs from plasma into oral fluid primarily occurs by passive diffusion of nonionized drugs, making lipophilicity and pKa key factors for excretion of drugs into and elimination from oral fluid.(3,5) For weak bases like cocaine and EME, ion trapping into oral fluid occurs because oral fluid pH is typically…”
BackgroundComparison of heroin and cocaine concentrations in saliva with concentrations in blood and plasma
Jenkins, A. J., Oyler, J. M., & Cone, E. J. (1995) · Journal of Analytical Toxicology · doi:10.1093/jat/19.6.359 · Cited by 181 · cited 2×
“Cocaine was the predominant analyte found in oral fluid after single SC, intravenous, intranasal, and smoked cocaine doses.(22,25) Interestingly, Jufer et al reported that EME predominated in oral fluid after repeated oral cocaine doses, possibly as a result of metabolite accumulation during repeated dosing.”
BackgroundSelf-citationJufer, R. A., Wstadik, A., Walsh, S. L., Levine, B. S., & Cone, E. J. (2000) · Journal of Analytical Toxicology · doi:10.1093/jat/24.7.467 · Cited by 137
Self-citation
Cited by
Oral fluid drug testing: analytical approaches, issues and interpretation of results
Desrosiers, N. A., & Huestis, M. A. (2019) · Journal of Analytical Toxicology · doi:10.1093/jat/bkz048 · Cited by 123
Self-citationDetection of drugs in simultaneously collected samples of oral fluid and blood
Bakke, E., Høiseth, G., Arnestad, M., & Gjerde, H. (2019) · Journal of Analytical Toxicology · doi:10.1093/jat/bky079 · Cited by 25
Comparing drug detection in oral fluid and blood: data from a national sample of nighttime drivers
Kelley-Baker, T., Moore, C., Lacey, J. H., & Yao, J. (2014) · Traffic Injury Prevention · doi:10.1080/15389588.2013.796042 · Cited by 24
Metadata
- Authors
- Scheidweiler, K. B., Kolbrich Spargo, E. A., Kelly, T. L., Cone, E. J., Barnes, A. J., & Huestis, M. A.
- Venue
- Therapeutic Drug Monitoring
- Published
- 2010-10
- Volume
- 32
- Issue
- 5
- Pages
- 628-637
- ISSN
- 0163-4356 (ISSN-L)
- OpenAlex
- W2059616695
- Cited by
- 88
- References
- 4
- FWCI
- 5.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.