The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Therapeutic Drug Monitoring of Antiepileptic Drugs by Use of Saliva
Abstract
Blood (serum/plasma) antiepileptic drug (AED) therapeutic drug monitoring (TDM) has proven to be an invaluable surrogate marker for individualizing and optimizing the drug management of patients with epilepsy. Since 1989, there has been an exponential increase in AEDs with 23 currently licensed for clinical use, and recently, there has been renewed and extensive interest in the use of saliva as an alternative matrix for AED TDM. The advantages of saliva include the fact that for many AEDs it reflects the free (pharmacologically active) concentration in serum; it is readily sampled, can be sampled repetitively, and sampling is noninvasive; does not require the expertise of a phlebotomist; and is preferred by many patients, particularly children and the elderly. For each AED, this review summarizes the key pharmacokinetic characteristics relevant to the practice of TDM, discusses the use of other biological matrices with particular emphasis on saliva and the evidence that saliva concentration reflects those in serum. Also discussed are the indications for salivary AED TDM, the key factors to consider when saliva sampling is to be undertaken, and finally, a practical protocol is described so as to enable AED TDM to be applied optimally and effectively in the clinical setting. Overall, there is compelling evidence that salivary TDM can be usefully applied so as to optimize the treatment of epilepsy with carbamazepine, clobazam, ethosuximide, gabapentin, lacosamide, lamotrigine, levetiracetam, oxcarbazepine, phenobarbital, phenytoin, primidone, topiramate, and zonisamide. Salivary TDM of valproic acid is probably not helpful, whereas for clonazepam, eslicarbazepine acetate, felbamate, pregabalin, retigabine, rufinamide, stiripentol, tiagabine, and vigabatrin, the data are sparse or nonexistent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chiron, C., Marchand, M., Tran, A., Rey, E., d'Athis, P., Vincent, J., Dulac, O., & Pons, G. (2000) · The Lancet · doi:10.1016/s0140-6736(00)03157-3 · Cited by 568
Oral fluid collection: the neglected variable in oral fluid testing
Crouch, D. J. (2005) · Forensic Science International · doi:10.1016/j.forsciint.2005.02.028 · Cited by 228
The epidemiology of blood-injection-injury phobia
BIENVENU, O. J., & EATON, W. W. (1998) · Psychological Medicine · doi:10.1017/s0033291798007144 · Cited by 212
Cited by
Consensus Guidelines for Therapeutic Drug Monitoring in Neuropsychopharmacology: Update 2017
Hiemke, C., Bergemann, N., Clement, H., Conca, A., Deckert, J., Domschke, K., Eckermann, G., Egberts, K., Gerlach, M., Greiner, C., et al. (2018) · Pharmacopsychiatry · doi:10.1055/s-0043-116492 · Cited by 1,446
Therapeutic Drug Monitoring of Antiepileptic Drugs in Epilepsy: A 2018 Update
Patsalos, P. N., Spencer, E. P., & Berry, D. J. (2018) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0000000000000546 · Cited by 477
Self-citationWearable Electrochemical Sensors for the Monitoring and Screening of Drugs
Teymourian, H., Parrilla, M., Sempionatto, J. R., Montiel, N. F., Barfidokht, A., Van Echelpoel, R., De Wael, K., & Wang, J. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01318 · Cited by 423
Clinical and diagnostic utility of saliva as a non-invasive diagnostic fluid: a systematic review
Soares Nunes, L. A., Mussavira, S., & Sukumaran Bindhu, O. (2015) · Biochemia Medica · doi:10.11613/bm.2015.018 · Cited by 333
Saliva sampling: Methods and devices. An overview
Bellagambi, F. G., Lomonaco, T., Salvo, P., Vivaldi, F., Hangouët, M., Ghimenti, S., Biagini, D., Di Francesco, F., Fuoco, R., & Errachid, A. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.115781 · Cited by 303
Metadata
- Authors
- Patsalos, P. N., & Berry, D. J.
- Venue
- Therapeutic Drug Monitoring
- Published
- 2013-02
- Volume
- 35
- Issue
- 1
- Pages
- 4-29
- ISSN
- 0163-4356 (ISSN-L)
- OpenAlex
- W2081017554
- Cited by
- 190
- References
- 3
- FWCI
- 13.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.