CoChat

Blood pressure measurements are unreliable to diagnose hypertension in primary care

Sebo, Paul, Pechère-Bertschi, Antoinette, Herrmann, François R., Haller, Dagmar M., Bovier, Patrick · 2014 · Journal of Hypertension
Cited by 65

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: To evaluate the accuracy of blood pressure (BP) measurements performed by primary care physicians (PCPs), and to assess whether it improves following a short theoretical training. METHODS: Observational study in 26 primary care practices in Geneva, Switzerland. The PCPs were asked to measure BP on 10 volunteers, within the usual context of their practice. Two trained research assistants repeated the measures immediately after the PCPs. The PCPs were then randomized to receive detailed training documentation on standardized BP measurement (group I: 14 doctors) or information about high BP (group II: 12 doctors). Measures were repeated a few weeks later. We computed accuracy and diagnostic categorization of high BP comparing the PCPs' measurements to the average value of four measurements by the research assistants (gold standard). T-tests were used to compare measurements between the two educational groups, both at baseline and following exposure to the educational material. RESULTS: BP measurements were performed on 257 volunteers at baseline and 251 after training. At baseline, the mean BP difference between PCPs and the gold standard were 23.0 mmHg (21.3-24.6) for systolic and 15.3 mmHg (14.3-16.3) for DBP. Following training, the mean difference remained high [group I: 22.3 mmHg (20.4-24.2) and 14.4 mmHg (12.6-16.2); group II: 25.3 mmHg (22.7-27.9) and 17.0 mmHg (15.3-18.7)]. As a result, 24-32% volunteers were misdiagnosed as having systolic hypertension and 15-21% as having diastolic hypertension. CONCLUSION: Though widely used in the assessment of hypertension in ambulatory settings, in-office BP measurements are highly inaccurate, even following training.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/hjh.0000000000000058

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 65

Metadata

Authors
Sebo, P., Pechère-Bertschi, A., Herrmann, F. R., Haller, D. M., & Bovier, P.
Venue
Journal of Hypertension
Published
2014-03
Volume
32
Issue
3
Pages
509-517
ISSN
0263-6352 (ISSN-L)
OpenAlex
W1980716951
Cited by
65
References
5
FWCI
3.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Blood pressure measurements are unreliable to diagnose hypertension in primary care. https://app.cochat.ai/papers/10.1097/hjh.0000000000000058
The paper
Sebo, P., Pechère-Bertschi, A., Herrmann, F. R., Haller, D. M., & Bovier, P. (2014). Blood pressure measurements are unreliable to diagnose hypertension in primary care. Journal of Hypertension. https://doi.org/10.1097/hjh.0000000000000058

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.