European Society of Hypertension practice guidelines for ambulatory blood pressure monitoring
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Given the increasing use of ambulatory blood pressure monitoring (ABPM) in both clinical practice and hypertension research, a group of scientists, participating in the European Society of Hypertension Working Group on blood pressure monitoring and cardiovascular variability, in year 2013 published a comprehensive position paper dealing with all aspects of the technique, based on the available scientific evidence for ABPM. The present work represents an updated schematic summary of the most important aspects related to the use of ABPM in daily practice, and is aimed at providing recommendations for proper use of this technique in a clinical setting by both specialists and practicing physicians. The present article details the requirements and the methodological issues to be addressed for using ABPM in clinical practice, The clinical indications for ABPM suggested by the available studies, among which white-coat phenomena, masked hypertension, and nocturnal hypertension, are outlined in detail, and the place of home measurement of blood pressure in relation to ABPM is discussed. The role of ABPM in pharmacological, epidemiological, and clinical research is also briefly mentioned. Finally, the implementation of ABPM in practice is considered in relation to the situation of different countries with regard to the reimbursement and the availability of ABPM in primary care practices, hospital clinics, and pharmacies.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These disrupted diurnal profiles seem to provide independent prognostic information beyond that of average BP levels.”
From Blood pressure and its variability: classic and novel measurement techniques (2022) · cites this paper as [23]
In the citing paper
“Across a 24 h period, different diurnal BP profiles, including a nocturnal non-dipping BP pattern22, extreme nocturnal dipping in selected individuals23, an exaggerated morning BP surge24 or maximal systolic BP levels25, can predict an increased risk of adverse cardiovascular outcomes.”
From Blood pressure and its variability: classic and novel measurement techniques (2022) · cites this paper as [23]
In the citing paper
“There is strong evidence that OH is frequently associated with a nocturnal 'non-dipping' or even 'reverse-dipping' BP pattern in patients with autonomic failure, with relevant therapeutic and prognostic implications 140,148-151”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [148]
In the citing paper
“ABPM has been indicated as the most reliable and accurate measurement of BP for diagnosing hypertension and while assessing the response to therapy [2], as it provides information about specific patterns of BP behavior, such as nocturnal dipping, morning surge and short-term variability over 24-h [2,166–168]”
In the citing paper
“The threshold for BP normality is indicated as similar for HBP and ambulatory daytime BP (≥135/85 mmHg), whereas a lower threshold is recommended for 24-h ABP (≥130/80 mmHg) [1,2,9,166]”
Citations
Cites
Mancia, G., Fagard, R., Narkiewicz, K., Redón, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2013) · Journal of Hypertension · doi:10.1097/01.hjh.0000431740.32696.cc · Cited by 5,655
Self-citationEuropean Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationParati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Self-citationAmbulatory Blood Pressure Measurement: What Is the International Consensus?
O’Brien, E., Parati, G., & Stergiou, G. (2013) · Hypertension · doi:10.1161/hypertensionaha.113.02148 · Cited by 183
Self-citation
Cited by
Items 701–800 of 1,000
Long-term kidney follow-up after pediatric acute kidney support therapy for children less than 15 kg
Gülçek, Ö. N., Gülhan, B., Kesici, S., Şükür, E. D. K., Hayran, M., Özaltın, F., Düzova, A., Bayrakçı, B., & Topaloğlu, R. (2023) · Pediatric Nephrology · doi:10.1007/s00467-023-06013-w · Cited by 3
Home (Self) Monitoring of Blood Pressure
Parati, G., & Ochoa, J. E. (2015) · Springer eBooks · doi:10.1007/978-3-319-22771-9_2 · Cited by 4
Self-citationOstroumova, O. D., & Кочетков, А. И. (2019) · Rational Pharmacotherapy in Cardiology · doi:10.20996/1819-6446-2019-15-4-558-567 · Cited by 3
Liu, P., Chen, Y., Wang, B., Wu, S. Y., Zeng, L., Cen, Z., Yang, D., Wang, H., Chen, X., Wang, L., et al. (2021) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2021.11.003 · Cited by 4
From Risk Prediction Models to Risk Assessment Service: A Formulation of Development ParadigmPreprint
Xia, E., Yu, Y., Xu, E., Mei, J., & Sun, W. X. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1903.07551 · Cited by 3
Argyris, A., Samara, S., & Protogerou, A. D. (2020) · Journal of Hypertension · doi:10.1097/hjh.0000000000002388 · Cited by 3
“Recent guidelines suggested more loose criteria [9] than the one used by Topouchian et al.”
MethodZabawa, C., Charra, C., Waldner, A., Morel, G., Zeller, M., Guilloteau, A., & Mazalovic, K. (2020) · Journal of Clinical Hypertension · doi:10.1111/jch.13903 · Cited by 4
Laugesen, E., Svendsen, A. N., Vernstrøm, L., Halkjær, L., Dons-Jensen, A., Funck, K. L., Hansen, K. W., & Poulsen, P. L. (2024) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000689 · Cited by 3
May, N., Fitzgerald, Z., Broyd, S. J., do Rosario, V. A., Roodenrys, S. J., Bliokas, V. V., Thomas, S. J., Potter, J., George, J., Weston–Green, K., et al. (2025) · Nutrition Research · doi:10.1016/j.nutres.2025.04.006 · Cited by 3
Kalampokini, S., Pilavas, A., Tsalamandris, G., Hadjigeorgiou, G. M., & Bargiotas, P. (2025) · Chronobiology International · doi:10.1080/07420528.2025.2515972 · Cited by 2
“While reduced dipping is a non-specific pattern influenced by several factors such as arterial hypertension or sleep disorders (Parati et al. 2014), reverse dipping is common in PD (Ejaz et al. 2006; Fanciulli et al. 2014; Milazzo et al. 2018).”
Blood Pressure Variability as a Diagnostic Marker for α‐Synucleinopathy in Patients With Orthostasis
Woo, T., Kim, J.-E., Kim, K., Baik, K., Park, J., Lee, S., Park, E., Lee, C., Kim, B., & Kim, J. (2025) · Journal of the American Heart Association · doi:10.1161/jaha.125.043276 · Cited by 2
“31”
Prevalence and determinants of masked hypertension among patients with type 2 diabetes mellitus
Oshaju, H., Chori, B. S., Reng, R. S., Anumah, F., & Odili, A. N. (2025) · Journal of Human Hypertension · doi:10.1038/s41371-025-01084-8 · Cited by 2
“Measurement was performed according to the European Society of Hypertension guideline on ambulatory blood pressure monitoring using the Mobil O Graph ABPM monitor manufactured in Stolberg, Germany and validated by the British Hypertension Society protocol [6, 7].”
Li, S., Mao, B., Zhang, J., Zhang, J., Gong, Y., Xia, S., Zhu, Y., Hong, X., & Yang, Y. (2026) · Biological Rhythm Research · doi:10.1080/09291016.2026.2613705 · Cited by 2
“All participants with complete data of 24 h ambulatory BP achieved a complete measurement of ambulatory BP recording referred to the European Society of Hypertension, with ≥70% about planned BP readings and with at least 7 nighttime and 20 daytime BP readings (Parati et al. 2014).”
2024 Thai guidelines on the treatment of hypertension
Kunanon, S., Kotruchin, P., Chattranukulchai, P., Chotruangnapa, C., Roubsanthisuk, W., Vathesatogkit, P., Kunavisarut, T., Silaruks, S., Tejavanija, S., Wataganara, T., et al. (2025) · Asian Biomedicine · doi:10.2478/abm-2025-0034 · Cited by 4
Lule, N. O., Savcılıoğlu, M. D., Lule, K. O., & Sucu, M. (2026) · Medicina · doi:10.3390/medicina62050974 · Cited by 2
“However, most studies examining DASH adherence and blood pressure have relied on office-based measurements, which are subject to white-coat effects, masked hypertension, and substantial short-term variability [13,14].”
Pasricha, S. V., Cohen, D. L., Shulman, R., Byfield, R. L., Cohen, J. B., CRIC Study Investigators, Anderson, A. H., Appel, L. J., Chen, J., Cohen, D. L., et al. (2026) · Journal of Human Hypertension · doi:10.1038/s41371-026-01166-1 · Cited by 3
“The 24-h ambulatory SBP and diastolic BP (DBP) variability (separate continuous secondary outcomes) were calculated using average real variability (i.e., the sum of the absolute differences in consecutive ambulatory BP measurements divided by the total number of measurements minus one) [14].”
Danninger, K., Athanasopoulou, E., Agharazii, M., Argyris, A., Bahous, S. A., Banegas, J. R., Binder, R. K., Blacher, J., Brandão, A. A., Brandt, M. C., et al. (2026) · Journal of the American Heart Association · doi:10.1161/jaha.125.048665 · Cited by 2
“14 cSBP was determined from brachial waveforms, as recorded with the cuff at the level of DBP, calibrated with MAP/DBP (cSBP C2) or SBP/DBP (cSBP C1), and processed with the ARCSolver transfer function.”
Self-citationHernán Prat, M., Abufhele, A., Alarcón, G., Barquín, I., Escobar, E., Fernández, M., Lanas, F. T., & Varleta, P. E. (2017) · Revista chilena de cardiología · doi:10.4067/s0718-85602017000300264 · Cited by 10
Kanegusuku, H., Correia, M. D. A., Longano, P., Ritti‐Dias, R. M., Wolosker, N., & Cucato, G. G. (2022) · PLoS ONE · doi:10.1371/journal.pone.0267849 · Cited by 2
Evaluation and Management of Hypertension in Children
Larkins, N., Lurbe, E., & Flynn, J. T. (2022) · Springer eBooks · doi:10.1007/978-3-030-52719-8_123 · Cited by 2
Self-citationTheodorakopoulou, M. P., Alexandrou, M. E., Iatridi, F., Καρπέτας, Α., Geladari, V., Pella, E., Alexiou, S., Sidiropoulou, M., Ziakka, S., Papagianni, A. A., et al. (2022) · International Urology and Nephrology · doi:10.1007/s11255-022-03369-0 · Cited by 2
“ABPM recordings were considered satisfactory and used for the analysis if the following criteria were met: (1) > 80% of recordings were valid, (2) ≤ 2 non-consecutive day-hours with < 2 valid measurements, and (3) ≤ 1 night-hour without valid recording for each 24-h period [28].”
BackgroundMethodNilsson, G. H., & Lindam, A. P. (2024) · BMC Cardiovascular Disorders · doi:10.1186/s12872-023-03701-1 · Cited by 2
Kim, K. H., Chung, J. H., Jang, S., Kim, B.-K., Munakata, M., & Rhee, M. (2024) · Medicina · doi:10.3390/medicina60091522 · Cited by 2
Bekler, Ö., & Kurtul, A. (2025) · Medicina · doi:10.3390/medicina61050794 · Cited by 2
“This suggests that while inflammation may be a feature of the non-dipping phenotype, it may not directly mediate acute ischemic injury during PCI.”
Features of vitamin B6 profile in children and adolescents with vasovagal syncope
Kovalchuk, T. (2020) · Modern pediatrics Ukraine · doi:10.15574/sp.2020.108.61 · Cited by 2
Arterial stiffness and atherosclerosis: mechanistic and pathophysiologic interactions
Kario, K. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-91391-1.00038-8 · Cited by 3
Self-citationKwon, C. H., Lee, H., Lee, J. H., Kim, M., & Sung, K. (2022) · Journal of Hypertension · doi:10.1097/hjh.0000000000003277 · Cited by 2
Dai, J., Wu, H.-Y., Jiang, X.-D., Tang, Y.-J., Tang, H., Li, M., Huang, N., Gao, J.-Y., Li, J., Baker, J. S., et al. (2023) · Frontiers in Pediatrics · doi:10.3389/fped.2023.1062300 · Cited by 4
“Blood pressure values <130/80 mmHg over 24 h, <135/85 mmHg during the daytime and <120/70 mmHg at night were categorized as normotensive (20).”
BackgroundThe frequency of hypertension in patients with pathological obesity
Moczulska, B., Leśniewska, S., Nowek, P., Osowiecka, K., & Gromadziński, L. (2023) · Medical Research Journal · doi:10.5603/mrj.a2023.0003 · Cited by 2
Güven, A. T. (2023) · Nigerian Journal of Clinical Practice · doi:10.4103/njcp.njcp_510_23 · Cited by 2
Agius, R., Pace, N. P., & Fava, S. (2024) · Journal of Nutrition and Metabolism · doi:10.1155/2024/5528250 · Cited by 4
“…after 5 minute rest in the seated position using a clinically validated digital sphygmomanometer with an appropriately sized cuf for each participant and using the average of the second and third readings for analyses, in accordance with the European Society of Hypertension Guidelines [31].”
MethodEliseeva, L. N., Tikhomirova, N. Y., Ждамарова, О. И., Kartashova, S. V., & Малхасян, И. Г. (2024) · South Russian Journal of Therapeutic Practice · doi:10.21886/2712-8156-2024-5-1-78-85 · Cited by 2
Ballegaard, E. L. F., Carlson, N., Jørgensen, M. B., Sørensen, I. M. H., Trankjær, H., Almarsdóttir, A. B., Bro, S., Feldt‐Rasmussen, B., Kamper, A., & for The Copenhagen CKD Cohort Study Group (2024) · Clinical Kidney Journal · doi:10.1093/ckj/sfae158 · Cited by 3
“Day-time BP 135/85 mmHg and nocturnal BP 120/70 mmHg were considered normal [27 ].”
BackgroundIlyina, T. S., Gorbunov, V. M., Lukyanov, М. М., Koshelyaevskaya, Y. N., & Drapkina, O. M. (2024) · CARDIOVASCULAR THERAPY AND PREVENTION · doi:10.15829/1728-8800-2024-4012 · Cited by 2
Twenty-four-hour ambulatory central blood pressure: new perspectives for blood pressure measurement?
Salvi, P., Schillaci, G., & Parati, G. (2014) · Journal of Hypertension · doi:10.1097/hjh.0000000000000318 · Cited by 2
Self-citationSalvo, F., Lonati, C., Albano, M. F., Fogliacco, P., Errani, A. R., Vallo, C., Berardi, M., Meinero, V., Muzzulini, C. L., & Morganti, A. (2016) · High Blood Pressure & Cardiovascular Prevention · doi:10.1007/s40292-016-0161-4 · Cited by 2
High blood pressure and syncope: orthostatic hypotension as a link
Rafanelli, M., & Ungar, A. (2016) · Monaldi Archives for Chest Disease · doi:10.4081/monaldi.2015.729 · Cited by 3
“Nei pazienti incapaci di completare il test del cammino si osserva una correlazione negativa tra PA e mortalità [11].”
BackgroundArterial Stiffness and Blood Pressure Variability
Salvi, P. (2016) · Springer eBooks · doi:10.1007/978-3-319-40501-8_3 · Cited by 2
Neumann, F., Ewen, S., Mortensen, K., NEF, H. M., Zeller, T., Ojeda, F., Sydow, K., Mahfoud, F., Böhm, M., Hamm, C. W., et al. (2016) · Biomarkers in Medicine · doi:10.2217/bmm-2016-0098 · Cited by 3
Malaise, lipothymie et syncope
Cambournac-Buan, A., Dadone, B. C., & Trinh-Duc, A. (2014) · Time to knit · doi:10.1016/s1241-8234(22)47282-8 · Cited by 3
Abnormal blood pressure dipping in diabetic kidney disease: A black‐race nightmare?
Stavropoulos, K., Imprialos, K. P., & Doumas, M. N. (2017) · Journal of Clinical Hypertension · doi:10.1111/jch.13078 · Cited by 2
Dvornyk, V. M., Бєлікова, І. В., Shylkina, L. M., Filatova, V. L., & Martynenko, N. M. (2019) · Wiadomości Lekarskie · doi:10.36740/wlek201905226 · Cited by 11
Potential of nicergoline in polymorbidity and cognitive impairment (clinical case)
Ostroumova, O. D., Кочетков, А. И., Оstroumova, Т. М., & Клепикова, М. В. (2020) · Medical alphabet · doi:10.33667/2078-5631-2020-19-11-18 · Cited by 2
Vendramini, L. C., Rodrigues, F. G., Dalboni, M. A., de Carvalho, J. T. G., Batista, M. C., Nishiura, J. L., & Heilberg, I. P. (2021) · Human Nutrition & Metabolism · doi:10.1016/j.hnm.2021.200121 · Cited by 2
A comparative analysis of ambulatory BP profile and arterial stiffness between CAPD and APD
Vaios, V., Georgianos, P. I., Vareta, G., Dounousi, E. C., Eleftheriadis, T., Papagianni, A. A., Zebekakis, P. E., & Liakopoulos, V. (2021) · Journal of Human Hypertension · doi:10.1038/s41371-021-00516-5 · Cited by 2
Xu, S., Zeng, W., Li, Y., Chen, L., Xie, J., & Wang, J. (2021) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000527 · Cited by 3
Self-citationAksoy, G. K., Yapar, D., Koyun, N. S., & Doğan, Ç. S. (2021) · Cardiology in the Young · doi:10.1017/s1047951121003450 · Cited by 3
Mallamaci, F., Tripepi, R., Torino, C., Tripepi, G. L., Sarafidis, P. A., & Zoccali, C. (2022) · Journal of Nephrology · doi:10.1007/s40620-022-01281-5 · Cited by 3
“A number of studies associated an increased morning rise in systolic BP with various indicators of target organ damage including left ventricular hypertrophy (LVH), diastolic dysfunction, myocardial ischemia, microalbuminuria, brain white matter lesions, carotid intima-media thickening, and endothelial * Carmine Zocca…”
BackgroundMethodInfluentialFundus Images Classification of Diabetic Retinopathy using MobileNetV2
Yassin, N. I. R. (2023) · International Journal of Computer Science and Mobile Computing · doi:10.47760/ijcsmc.2023.v12i05.006 · Cited by 2
Update on the management of hypertension in 2023
Rabi, D. M. (2023) · Canadian Primary Care Today · doi:10.58931/cpct.2023.1212 · Cited by 2
Alp, A., Saruhan, E., Doğan, E., Genek, D. G., & Huddam, B. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12216885 · Cited by 2
“BP-recorded readings exceeding 75% of the expected measurements were considered for analysis in accordance with the European Society of Hypertension guidelines [12].”
MethodCandemir, M., & Kızıltunç, E. (2024) · Clinical Research in Cardiology · doi:10.1007/s00392-024-02514-2 · Cited by 2
“Also, we know that reverse dipper can be seen in the healthy population [7].”
Tarta, D., Caldararu, C. D., Tarta, C., Frigy, A., Caraşca, E., Carlan, O., & Dogaru, A. (2015) · Acta Marisiensis. Seria Medica · doi:10.1515/amma-2015-0029 · Cited by 2
White-coat hypertension and masked hypertension: an update
Artom, N., Salvo, F., & Camardella, F. (2015) · Italian Journal of Medicine · doi:10.4081/itjm.2015.662 · Cited by 3
La monitorización ambulatoria de la presión arterial no siempre es necesaria
Divisón, J. A. (2016) · Hipertensión y Riesgo Vascular · doi:10.1016/j.hipert.2016.08.001 · Cited by 2
Nikitina, N. M., Romanova, T. A., Афанасьев, И. А., Tyapkina, M. A., & Rebrov, A. P. (2016) · Rational Pharmacotherapy in Cardiology · doi:10.20996/1819-6446-2016-12-5-547-552 · Cited by 3
White-Coat and Masked Hypertension
Parati, G., & Ochoa, J. E. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-42973-3.00012-3 · Cited by 2
Self-citationLeft Ventricular Remodeling and Masked Hypertension: Don’t Forget Nighttime Diastolic Blood Pressure
Tadić, M., & Cuspidi, C. (2019) · American Journal of Hypertension · doi:10.1093/ajh/hpz047 · Cited by 2
Pediatric ambulatory blood pressure monitoring grows up
Flynn, J. T. (2014) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2014.07.001 · Cited by 2
Koochakkhani, S., Nabizadeh, F., Nejatizadeh, A., & Eftekhar, E. (2021) · Meta Gene · doi:10.1016/j.mgene.2021.100914 · Cited by 1
Крутиков, Е. С., Tsvetkov, V. A., Chistyakova, S., & Akaev, R. O. (2021) · Nephrology (Saint-Petersburg) · doi:10.36485/1561-6274-2021-25-6-56-62 · Cited by 1
Okpechi, I. G., Ringrose, J., Padwal, R. S., & Bello, A. K. (2023) · Connected Health · doi:10.20517/ch.2022.18 · Cited by 2
Domingues, V., Cavalari, J. V., Grandolfi, K., Aguiar, A. F., Borghi, S. M., & Casonatto, J. (2024) · Journal of Dietary Supplements · doi:10.1080/19390211.2024.2414052 · Cited by 1
“According to hypertension guidelines (Parati et al. 2014), 24-h ambulatory blood pressure monitoring is used to asses nocturnal blood pressure dips.”
Özdemir, G., & Buluş, A. D. (2025) · Klinische Pädiatrie · doi:10.1055/a-2510-5233 · Cited by 1
Buso, G., Gatta, R., Corvini, F., Laera, N., Rosei, C. A., Paini, A., Bulgari, G., Petroboni, B., Bertacchini, F., Aggiusti, C., et al. (2025) · Hypertension Research · doi:10.1038/s41440-025-02135-w · Cited by 1
“The recordings were included in the study only if valid BP readings were ≥ 70% of the expected readings and at least one valid reading per hour was available for ≥ 21 h [12].”
Asferg, C. L., Andersen, U. B., & Jeppesen, J. (2025) · Peptides · doi:10.1016/j.peptides.2025.171410 · Cited by 1
“BP was measured by automatic 24-hour ABP recordings (Spacelabs ABP 90207, Redmont, California, USA) and complied with European guidelines for ABP measurements [7].”
Fernández-Castro, I., Vázquez-Agra, N., Albán-Salgado, A., Sanchez-Andrade, M., Lopez-Casal, S., Cruces‐Sande, A., Seoane-Casqueiro, O., Pose‐Reino, A., & Ameijeiras, Á. H. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms26136115 · Cited by 2
“As for the relationship between daytime and nighttime BP levels, nSBP dipping and nDBP dipping were calculated as the ratio of (a) the difference between daytime and nighttime indices to (b) the daytime index, expressed as a percentage [47,48].”
2025 Thai Hypertension Society Guidance for Ambulatory Blood Pressure Monitoring in Adults
Wanthong, S., Chattranukulchai, P., Chotruangnapa, C., Kotruchin, P., Roubsanthisuk, W., Vathesatogkit, P., & Sukonthasarn, A. (2025) · Journal of Clinical Hypertension · doi:10.1111/jch.70136 · Cited by 3
“The information obtained from ABPM is complementary to that generated by HBPM, and a rational combination of these two measurement techniques is recommended [41–44].”
How to screen and diagnose hypertension
Stergiou, G. S., Bilo, G., Camafort, M., de la Sierra, A., Κόλλιας, Α., Palatini, P., & Parati, G. (2025) · European Journal of Preventive Cardiology · doi:10.1093/eurjpc/zwaf674 · Cited by 4
Self-citationAssociation of Dialysis Shift with Morning Surge in Blood Pressure and Dipping Pattern
Theodorakopoulou, M. P., Iatridi, F., Karagiannidis, A. G., Georgiou, A., Manti, S., Καρπέτας, Α., Anyfanti, P., Gavriilaki, E., & Sarafidis, P. A. (2025) · American Journal of Hypertension · doi:10.1093/ajh/hpaf218 · Cited by 1
Nora, T., & Hangouche, A. J. E. (2025) · Romanian Journal of Cardiology · doi:10.2478/rjc-2025-0037 · Cited by 1
Sander, L., Chiaro, G., Abelardo, D., Ingle, G. T., McNamara, P., Gillmore, J. D., Reilly, M. M., & Iodice, V. (2025) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp-2025-337061 · Cited by 1
Cerquoni, G., Ayala-Hernández, J., López-Sánchez, C., Brigli, P., Barbosa, A., & Castro, S. (2026) · SN Comprehensive Clinical Medicine · doi:10.1007/s42399-026-02337-4 · Cited by 1
Renal denervation revisited: is patient selection the missing link between failure and success?
Shahverdi, E., Herda, L. R., Manouchehri, R., Shahi, S., & Lange, M. (2026) · Clinical Hypertension · doi:10.5646/ch.2026.32.e20 · Cited by 1
“ABPM has therefore emerged as a critical tool for confirming sustained hypertension and excluding white-coat effect prior to consideration of RDN [26,27].”
InfluentialMwipatayi, B. P., Dodd, J., Carnagarin, R., Mori, T. A., Golledge, J., Burrows, S., Watts, G. F., Iida, O., & Schlaich, M. P. (2026) · Journal of Clinical Hypertension · doi:10.1111/jch.70309 · Cited by 1
“Two measurements obtained at trough were averaged for analyses [ 39–41 ].”
Existence Of Right Ventricular Structural And Functional Changes In Essential Hypertension And
Minashvili, A., & Rekhviashvili, A. (2021) · European Scientific Journal ESJ · doi:10.19044/esj.2021.v17n21p1 · Cited by 2
“…accounted for daytime and night-time BP in the same statistical model found that night-time BP is a stronger predictor of outcomes than daytime BP (Parati et al., 2014). www.eujournal.org 12 Historically, studies mostly addressed left ventricular changes in hypertensive patients with different…”
BackgroundAzizi, M., Lorthioir, A., & Amar, L. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-88369-6.00047-5 · Cited by 2
McEvoy, J. W., McCarthy, C. P., Brouwers, S., & Others, A. (2025) · HYPERTENSION · doi:10.22141/2224-1485.17.4.2024.372 · Cited by 2
Fava, C., Stocchetti, F., & Bonafini, S. (2025) · Biomedicines · doi:10.3390/biomedicines14010040 · Cited by 1
“Related, although distinct, is the concept of reverse dipping, which is the pattern characterized by the inversion of the normal day-to-night BP ratio, with nighttime BP values higher than daytime ones [6].”
Acute hot‐water immersion augments the diastolic blood pressure nocturnal dip in healthy adults
Leaney, S. F., Ponce, F. A. F., Owen, T. F., Harvey, B. L., Davies‐Wilson, O. N., Brand, O. M. A., Coombs, G. B., Moore, J. P., & Oliver, S. J. (2026) · Experimental Physiology · doi:10.1113/ep093583 · Cited by 1
“In accordance with the European Society for Hypertension practice guidelines (Parati et al., 2014; Stergiou et al., 2021), daytime and nighttime periods were defined by participants’ self-reported sleep times, or when absent ( n = 1) were defined as fixed time periods (daytime 08.00–20.00 h and…”
InfluentialLang, M., Vega, J. L., Bilo, G., Opazo‐Díaz, E., Diaz, G. A., & Maggioni, M. A. (2026) · Frontiers in Physiology · doi:10.3389/fphys.2026.1747092 · Cited by 1
“Non-dipping patterns have been associated with increased cardiovascular risk in other populations (Parati et al., 2014a; McHill et al., 2022) and are highlighted in current ESH guidelines (Parati et al., 2014b; Parati et al., 2025).”
Self-citationCorrelation of hypoxic burden with blood pressure diurnal rhythm in obstructive sleep apnea
Wang, Q., Lan, X., Zhang, Z., Song, X., Wu, S., Dong, Y., Jia, S., & Yuan, H. (2026) · SLEEP · doi:10.1093/sleep/zsag167 · Cited by 1
“All subjects underwent the 24-h ABPM (SunTech Oscar 2, American) in the morning immediately after the PSG sleep study, according to internationally recommended guidelines [ 26, 27].”
Triantafyllidi, H., Xenogiannis, I., Ikonomidis, I., Pavlidis, G., Schoinas, A., Palaiodimos, L., Vlachos, S., & Lekakis, J. P. (2016) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000213 · Cited by 1
Ambulatory Blood Pressure Monitoring in Clinical Hypertension Management
White, W. B., & Malha, L. P. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-42973-3.00011-1 · Cited by 1
Bobrie, G., Amar, L., Faucon, A., Madjalian, A.-M., & Azizi, M. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-42973-3.00043-3 · Cited by 1
Vaios, V., Georgianos, P. I., Vareta, G., Divanis, D., Dounousi, E. C., Eleftheriadis, T., Papagianni, A. A., Zebekakis, P. E., & Liakopoulos, V. (2021) · Peritoneal Dialysis International · doi:10.1177/0896860821996927 · Cited by 1
“The monitor was programmed to measure BP three times per hour during daytime (07:00 to 22:59) and two times per hour during night-time (23:00 to 06:59).(18) ABPM was considered complete when >80% of readings were valid with 2 non-consecutive daytime hours with <2 valid recordings and 1 night-time hour without valid re…”
BackgroundMethodBalcı, C., Eşme, M., Sümer, F., Asıl, S., Yavuz, B., Tuna, R., Özsürekçi, C., Çalışkan, H., Ünsal, P., Ayçiçek, G. Ş., et al. (2021) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000532 · Cited by 1
ХАРАКТЕРИСТИКИ ВАРІАБЕЛЬНОСТІ СЕРЦЕВОГО РИТМУ В ДІТЕЙ ІЗ КАРДІОГЕННИМИ СИНКОПЕ
Kovalchuk, T. (2021) · Bulletin Of Medical And Biological Research · doi:10.11603/bmbr.2706-6290.2021.3.12217 · Cited by 1
TAMURA, T. (2017) · Springer eBooks · doi:10.1007/978-3-319-69362-0_4 · Cited by 1
Povetkin, S. V., & Александрович, К. А. (2022) · Arterial’naya Gipertenziya (Arterial Hypertension) · doi:10.18705/1607-419x-2022-28-1-17-26 · Cited by 1
Liu, K., Ma, Y., Wang, Y., Zhang, Y., Li, L., Zhang, J., Jiang, J., Chen, R., & Wan, Y. (2022) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000607 · Cited by 1
Self-citationCerveri, P., Sarti, M., Rossi, M., Alessandrelli, G., Lombardi, C., & Mainardi", L. (2022) · Computing in cardiology · doi:10.22489/cinc.2022.429 · Cited by 1
“BP measurement on a long-term basis has been identified as the main technique to detect hypertensive conditions [3].”
BackgroundArana-Morales, G., & Medina-Palomino, F. (2024) · Revista Colombiana de Cardiología · doi:10.24875/rccar.23000004 · Cited by 3
New advances in the treatment and diagnosis of hypertension in primary care: a literature review
Chuquitarco, Y. C. Q., Quilligana, S. F. M., Andrade, V. J. G., López, T. E. H., & Sánchez, P. M. C. (2024) · Sapienza International Journal of Interdisciplinary Studies · doi:10.51798/sijis.v5i1.739 · Cited by 1
Arterial Stiffness and Blood Pressure Variability
Parati, G., Ochoa, J. E., Schillaci, G., & Salvi, P. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15512-3.00048-9 · Cited by 2
Self-citationWang, J., Topouchian, J. A., Bricout-Hennel, S., Mu, J., Chen, L., Li, P., He, S., Luo, S., Jiang, W., Jiang, Y., et al. (2024) · Journal of Hypertension · doi:10.1097/hjh.0000000000003741 · Cited by 5
Self-citationMalano, D. J., Perea, J., Chamorro, L. G. G., Goldaracena, F., Mazuquín, A., Corzo, S. M., Denner, G., Racki, M., Zaidel, E. J., & Liprandi, A. S. (2024) · Revista de la Facultad de Ciencias Médicas de Córdoba · doi:10.31053/1853.0605.v81.n3.44619 · Cited by 1
Sex Differences in Ambulatory Central Blood Pressure and Arterial Stiffness in Hemodialysis Patients
Karagiannidis, A. G., Theodorakopoulou, M. P., Iatridi, F., Καρπέτας, Α., Georgiou, A., Manti, S., Anyfanti, P., Gavriilaki, E., Giannakoulas, G. A., & Sarafidis, P. A. (2025) · High Blood Pressure & Cardiovascular Prevention · doi:10.1007/s40292-025-00713-0 · Cited by 3
Zhang, Y., Wang, T., Fang, C., Yang, J., & Xu, J. (2025) · Heart & Lung · doi:10.1016/j.hrtlng.2025.06.011 · Cited by 1
Self-citationAmbulatory Monitoring of Blood Pressure: An Overview of Devices, Analyses, and Clinical Utility
White, W. B., & Barber, V. (2015) · Springer eBooks · doi:10.1007/978-3-319-22771-9_4 · Cited by 2
Metadata
- Authors
- Parati, G., Stergiou, G., O’Brien, E., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., Fagard, R., Graves, J., Head, G. A., Imai, Y., Kario, K., Lurbe, E., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Ogedegbe, G., Ohkubo, T., Omboni, S., Palatini, P., Redon, J., Ruilope, L. M., Shennan, A., Staessen, J. A., vanMontfrans, G., Verdecchia, P., Waeber, B., Wang, J., Zanchetti, A., & Zhang, Y.
- Affiliations
- University of Milano-Bicocca (IT)
- National and Kapodistrian University of Athens (GR)
- The University of Western Australia (AU)
- IRCCS Istituto Auxologico Italiano (IT)
- Ghent University (BE)
- Connolly Hospital Blanchardstown (IE)
- KU Leuven (BE)
- Mayo Clinic (US)
- Tohoku University (JP)
- Jichi Medical University (JP)
- Hospital General Universitario Gregorio Marañón (ES)
- Université Joseph Fourier (FR)
- University of Toronto (CA)
- New York University (US)
- Teikyo University (JP)
- Italian Institute of Telemedicine (IT)
- University of Padua (IT)
- Universidad Complutense de Madrid (ES)
- King's College London (GB)
- Maastricht University (NL)
- University of Amsterdam (NL)
- University of Lausanne (CH)
- University of Milan (IT)
- Chinese Academy of Medical Sciences & Peking Union Medical College (CN)
- Corresponding author
- Parati, Gianfranco
- Stergiou, George
- ORCID
- Parati, Gianfranco
- Stergiou, George
- Asmar, Roland
- Beilin, Lawrence
- Bilo, Grzegorz
- Dolan, Eamon
- Head, Geoffrey A.
- Imai, Yutaka
- Kario, Kazuomi
- Lurbe, Empar
- Mancia, Giuseppe
- Myers, Martin
- Ogedegbe, Gbenga
- Ohkubo, Takayoshi
- Omboni, Stefano
- Palatini, Paolo
- Ruilope, Luis M.
- Shennan, Andrew
- Staessen, Jan A.
- Verdecchia, Paolo
- Zanchetti, Alberto
- Zhang, Yuqing
- Venue
- Journal of Hypertension
- Published
- 2014-07
- Volume
- 32
- Issue
- 7
- Pages
- 1359-1366
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2034643992
- Semantic Scholar
- 05c8cfa0c089391bbae2ce663775c56c8e71478e
- Cited by
- 1,021
- References
- 4
- Citations by year
- 2026: 44 · 2025: 47 · 2024: 89 · 2023: 77 · 2022: 113 · 2021: 109 · 2020: 113 · 2019: 123 · 2018: 97 · 2017: 75 · 2016: 62 · 2015: 59 · 2014: 11
- FWCI
- 47.32
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Hypertension (publishedVersion)
- PubMed (publishedVersion)
- UWA Profiles and Research Repository (UWA) (submittedVersion)
- BOA (University of Milano-Bicocca) (submittedVersion)
- Research Publications (Maastricht University) (submittedVersion)
- Institutional Repositories DataBase (IRDB) (submittedVersion)
- IRIS (submittedVersion)
- Lirias (KU Leuven) (submittedVersion)
- SERVAL (Université de Lausanne) (submittedVersion)
- Funders
- European Society of Cardiology
- National Institutes of Health
- Japan Society for the Promotion of Science (25253059)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- ambulatory blood pressure monitoring, hypertension, white coat hypertension, masked hypertension, nocturnal hypertension, home blood pressure monitoring, indications, primary care, cardiovascular variability
- MeSH terms
- Adolescent, Adult, Atrial Fibrillation, Child, Female, Humans, Hypertension, Male, Obesity, Practice Patterns, Physicians', Software, Blood Pressure Monitoring, Ambulatory, White Coat Hypertension, Masked Hypertension
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.