CoChat

Estimation of central aortic blood pressure: a systematic meta-analysis of available techniques

Narayan, Om, Casan, Joshua, Szarski, Martin, Dart, Anthony M., Meredith, Ian T., Cameron, James D. · 2014 · Journal of Hypertension
Cited by 76

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Central aortic blood pressure (cBP) is often promoted to be a superior predictor of cardiovascular risk compared to brachial blood pressure, and brachial-central pulse pressure amplification is also suggested as prognostic. Several devices and techniques, each purporting to estimate cBP, have entered commercial use. The interchangeability of cBP measurements between devices and the influence of disease states on central to brachial pulse pressure amplification remain unclear. The useful measurement of cBP in clinical trials is dependent on clarification of these issues. METHOD: We performed a systematic meta-analysis of studies reporting cBP between 2000 and 2012. Studies were included if both central and brachial SBPs (cSBP and bSBP) were reported. Studies were categorized by technique and according to the prevalent disease state with the bSBP - cSBP difference calculated. Random-effects modeling (inverse variance weighted approach) was used to estimate the pooled mean difference associated with each technique. RESULTS: Of the 164 eligible studies, the SphygmoCor device was most commonly reported (110 studies), with direct carotid applanation second-most utilized (31 studies). In 30 included invasive cohorts, the measured cSBP did not differ significantly from the oscillometric bSBP recorded [mean difference 4.19 mmHg, 95% confidence interval (CI) -4.13 to 12.51], whereas mean differences of 12.77 mmHg (95% CI 11.93, 13.60) and 8.83 mmHg (95% CI 7.86, 9.79) were obtained with the SphygmoCor and carotid applanation estimates of cSBP, respectively (both P < 0.05). Conversely, the reported mean cSBP-to-bSBP differences measured across various disease states with SphygmoCor did not differ significantly. CONCLUSION: This meta-analysis suggests that noninvasive cBP estimation is device/technique-dependent. Consequently, caution is advisable in applying these devices and techniques across clinical studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/hjh.0000000000000249

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 76

Metadata

Authors
Narayan, O., Casan, J., Szarski, M., Dart, A. M., Meredith, I. T., & Cameron, J. D.
Venue
Journal of Hypertension
Published
2014-09
Volume
32
Issue
9
Pages
1727-1740
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2033375523
Cited by
76
References
5
FWCI
8.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Estimation of central aortic blood pressure: a systematic meta-analysis of available techniques. https://app.cochat.ai/papers/10.1097/hjh.0000000000000249
The paper
Narayan, O., Casan, J., Szarski, M., Dart, A. M., Meredith, I. T., & Cameron, J. D. (2014). Estimation of central aortic blood pressure: a systematic meta-analysis of available techniques. Journal of Hypertension. https://doi.org/10.1097/hjh.0000000000000249

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.