Night-time home versus ambulatory blood pressure in determining target organ damage
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: This study aimed to evaluate the association of night-time blood pressure (BP) assessed by home blood pressure (HBP) or ambulatory blood pressure (ABP) monitoring with preclinical target organ damage in untreated hypertension. METHODS: Untreated hypertensive study participants were evaluated with ABP monitoring (24-h) and HBP monitoring during daytime (6 days, duplicate morning and evening measurements) and night-time (automated asleep measurements, three nights, 3-hourly measurements/night). Target organ damage was assessed by echocardiographic left ventricular mass index (LVMI), common carotid intima-media thickness (cIMT), urine albumin excretion (UAE), and ankle-brachial index (ABI). RESULTS: A total of 131 study participants were analysed [mean age 52.1 ± 11.9 (SD) years, BMI 29.9 ± 5.3 kg/m2, men 58%, cardiovascular disease history 6.1%]. Daytime and night-time HBP were slightly higher than the respective ABP values (mean difference for systolic daytime/night-time 3.5 ± 10.6/2.6 ± 9.8 mmHg, P < 0.01 for both comparisons and diastolic -0.3 ± 6.8/1.2 ± 6.2 mmHg, P = NS/0.02, respectively). There was a strong correlation between daytime ABP and HBP (r = 0.71/0.72, systolic/diastolic), as well as between the respective night-time values (r = 0.80/0.79; all P < 0.01). Night-time ABP and HBP presented strong and comparable correlations with all the indices of preclinical target organ damage. In multivariate analyses, both LVMI (R2 = 0.26) and cIMT (R2 = 0.25) were determined by night-time systolic HBP, age and male sex; UAE (R2 = 0.28) by night-time systolic HBP and male sex; ABI (R2 = 0.20) by male sex and night-time home pulse pressure. CONCLUSION: In untreated hypertensives, night-time BP assessed by home monitoring appears to be as good as night-time ambulatory monitoring in determining preclinical target organ damage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationParati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837 · cited 4×
“These data are important because they support the role of HBP in the evaluation of treated individuals, which is the main indication of the method, namely the long-term follow-up of treated hypertensives [4].”
BackgroundMethodSelf-citationFagard, R. H., Celis, H., Thijs, L., Staessen, J. A., Clement, D. L., De Buyzere, M. L., & De Bacquer, D. A. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.100727 · Cited by 742
Predictive Role of the Nighttime Blood Pressure
Hansen, T. W., Li, Y., Boggia, J., Thijs, L., Richart, T., & Staessen, J. A. (2011) · Hypertension · doi:10.1161/hypertensionaha.109.133900 · Cited by 597
Bliziotis, I. A., Destounis, A., & Stergiou, G. S. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e3283531eaf · Cited by 261 · cited 1×
“Moreover, studies have shown daytime HBP to be as good as ABP in predicting target organ damage [14].”
BackgroundSelf-citationNighttime Home Blood Pressure and the Risk of Hypertensive Target Organ Damage
Ishikawa, J., Hoshide, S., Eguchi, K., Ishikawa, S., Shimada, K., Kario, K., & for the Japan Morning Surge-Home Blood Pressure Study Investigators Group (2012) · Hypertension · doi:10.1161/hypertensionaha.112.198101 · Cited by 123
Cited by
Kario, K., Kanegae, H., Tomitani, N., Okawara, Y., Fujiwara, T., Yano, Y., Hoshide, S., & on behalf of the J-HOP Study Group (2019) · Hypertension · doi:10.1161/hypertensionaha.118.12740 · Cited by 167
Nocturnal blood pressure measured by home devices: evidence and perspective for clinical application
Asayama, K., Fujiwara, T., Hoshide, S., Ohkubo, T., Kario, K., Stergiou, G. S., Parati, G., White, W. B., Weber, M. A., & Imai, Y. (2019) · Journal of Hypertension · doi:10.1097/hjh.0000000000001987 · Cited by 120
Self-citationKollias, A., Ntineri, A., & Stergiou, G. S. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001189 · Cited by 90
“Six studies fulfilled the requirements for inclusion in the meta-analysis [13,15,16,18,23,24].”
MethodInfluentialSelf-citationKollias, A., Andreadis, E., Agaliotis, G., Kolyvas, G. N., Achimastos, A., & Stergiou, G. S. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001562 · Cited by 34
Self-citationHuman Errors in Automated Office Blood Pressure Measurement: Still Room for Improvement
Elias, M. F., & Goodell, A. L. (2021) · Hypertension · doi:10.1161/hypertensionaha.120.16164 · Cited by 31
Metadata
- Authors
- Andreadis, E. A., Agaliotis, G., Kollias, A., Kolyvas, G., Achimastos, A., & Stergiou, G. S.
- Venue
- Journal of Hypertension
- Published
- 2016-03
- Volume
- 34
- Issue
- 3
- Pages
- 438-444
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2415345429
- Cited by
- 36
- References
- 6
- FWCI
- 4.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Night-time home versus ambulatory blood pressure in determining target organ damage. https://app.cochat.ai/papers/10.1097/hjh.0000000000000815
- The paper
- Andreadis, E. A., Agaliotis, G., Kollias, A., Kolyvas, G., Achimastos, A., & Stergiou, G. S. (2016). Night-time home versus ambulatory blood pressure in determining target organ damage. Journal of Hypertension. https://doi.org/10.1097/hjh.0000000000000815
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.