Cited by 34Blood Pressure and Hypertension StudiesCardiovascular Health and Disease PreventionNon-Invasive Vital Sign Monitoring

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

The optimal night-time home blood pressure monitoring schedule: agreement with ambulatory blood pressure and association with organ damage

Abstract

OBJECTIVE: Night-time home blood pressure (HBP) monitoring has emerged as a feasible, reliable and low-cost alternative to ambulatory blood pressure (ABP) monitoring. This study evaluated the optimal schedule of night-time HBP monitoring in terms of agreement with night-time ABP and association with preclinical target-organ damage. METHODS: Untreated hypertensive adults were evaluated with ABP (24-h) and HBP monitoring (daytime: six days, duplicate morning and evening measurements; night-time: three nights, three-hourly automated measurements/night), and determination of left ventricular mass index, common carotid intima-media thickness and urinary albumin excretion. RESULTS: A total of 94 patients with all nine night-time HBP measurements were analysed [mean age 51.8 ± 11.1 (SD) years, men 57%). By averaging an increasing number of night-time systolic HBP readings, there was a consistent trend towards stronger association of night-time HBP with night-time ABP (correlation coefficients r increased from 0.69 to 0.81), and with target-organ damage indices (for left ventricular mass index r increased from 0.13 to 0.22, carotid intima-media thickness 0.12-0.25, urinary albumin excretion 0.33-0.41). However, no further improvement in the association was observed by averaging more than four to six night-time readings. The diagnostic agreement between HBP and ABP in detecting nondippers was improved by averaging more readings, with a plateau at four readings (single reading: agreement 81%, kappa 0.37; four readings: 88%, 0.49; nine readings: 84%, 0.40). CONCLUSION: A two-night HBP schedule (six readings) appears to be the minimum requirement for a reliable assessment of night-time HBP, which gives reasonable agreement with ABP and association with preclinical organ damage.

Overview

Integrity signals

Registry

Crossref · 10.1097/hjh.0000000000001562

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Flagged first, then by citations

Show all 2 references

Research works printed but not linked: 22

  1. Mancia, 2013, 2013 ESH/ESC guidelines for the management of arterial hypertension: the Task Force for the management of arterial hypertension of the European Society of Hypertension (ESH) and of the European Society of Cardiology (ESC), J Hypertens, 31, 1281, 10.1097/01.hjh.0000431740.32696.cc · DOI · Paper page
  2. O’Brien, 2013, European Society of Hypertension position paper on ambulatory blood pressure monitoring, J Hypertens, 31, 1731, 10.1097/HJH.0b013e328363e964 · DOI · Paper page
  3. Piper, 2015, Diagnostic and predictive accuracy of blood pressure screening methods with consideration of rescreening intervals: a systematic review for the U.S. Preventive Services Task Force, Ann Intern Med, 162, 192, 10.7326/M14-1539 · DOI
  4. Hansen, 2007, Prognostic superiority of daytime ambulatory over conventional blood pressure in four populations: a meta-analysis of 7,030 individuals, J Hypertens, 25, 1554, 10.1097/HJH.0b013e3281c49da5 · DOI
  5. Parati, 2008, European Society of Hypertension guidelines for blood pressure monitoring at home: a summary report of the Second International Consensus Conference on Home Blood Pressure Monitoring, J Hypertens, 26, 1505, 10.1097/HJH.0b013e328308da66 · DOI · Paper page
  6. Stergiou, 2014, Home blood pressure monitoring: primary role in hypertension management, Curr Hypertens Rep, 16, 462, 10.1007/s11906-014-0462-8 · DOI
  7. Stergiou, 2011, Home blood pressure monitoring in the diagnosis and treatment of hypertension: a systematic review, Am J Hypertens, 24, 123, 10.1038/ajh.2010.194 · DOI
  8. Stergiou, 2014, Prognosis of white-coat and masked hypertension: International Database of HOme blood pressure in relation to Cardiovascular Outcome, Hypertension, 63, 675, 10.1161/HYPERTENSIONAHA.113.02741 · DOI · Paper page
  9. Fagard, 2008, Daytime and night-time blood pressure as predictors of death and cause-specific cardiovascular events in hypertension, Hypertension, 51, 55, 10.1161/HYPERTENSIONAHA.107.100727 · DOI · Paper page
  10. Ushio, 2009, Utility and feasibility of a new programmable home blood pressure monitoring device for the assessment of nighttime blood pressure, Clin Exp Nephrol, 13, 480, 10.1007/s10157-009-0192-4 · DOI
  11. Stergiou, 2012, Assessment of the diurnal blood pressure profile and detection of nondippers based on home or ambulatory monitoring, Am J Hypertens, 25, 974, 10.1038/ajh.2012.82 · DOI
  12. Ishikawa, 2014, Assessment of the reductions in night-time blood pressure and dipping induced by antihypertensive medication using a home blood pressure monitor, J Hypertens, 32, 82, 10.1097/HJH.0b013e328365c8a8 · DOI
  13. Andreadis, 2016, Night-time home versus ambulatory blood pressure in determining target organ damage, J Hypertens, 34, 438, 10.1097/HJH.0000000000000815 · DOI
  14. Lindroos, 2016, The association between home versus ambulatory nighttime blood pressure and end-organ damage in the general population, J Hypertens, 34, 1730, 10.1097/HJH.0000000000000995 · DOI
  15. Kollias, 2017, Association of night-time home blood pressure with night-time ambulatory blood pressure and target-organ damage: a systematic review and meta-analysis, J Hypertens, 35, 442, 10.1097/HJH.0000000000001189 · DOI · Paper page
  16. Ragazzo, 2010, Validation of the Microlife WatchBP O3 device for clinic, home, and ambulatory blood pressure measurement, according to the International Protocol, Blood Press Monit, 15, 59, 10.1097/MBP.0b013e32833531ca · DOI
  17. Stergiou, 2010, Are there really differences between home and daytime ambulatory blood pressure? Comparison using a novel dual-mode ambulatory and home monitor, J Hum Hypertens, 24, 207, 10.1038/jhh.2009.60 · DOI
  18. Stergiou, 2007, Validation of the Microlife WatchBP Home device for self home blood pressure measurement according to the International Protocol, Blood Press Monit, 12, 185, 10.1097/MBP.0b013e3280b083ce · DOI
  19. Stergiou, 1998, Self-monitoring of blood pressure at home: how many measurements are needed?, J Hypertens, 16, 725, 10.1097/00004872-199816060-00002 · DOI · Paper page
  20. Verberk, 2006, The optimal scheme of self blood pressure measurement as determined from ambulatory blood pressure recordings, J Hypertens, 24, 1541, 10.1097/01.hjh.0000239289.87141.b6 · DOI
  21. Stergiou, 2007, The optimal schedule for self-monitoring of blood pressure by patients at home, J Hypertens, 25, 1992, 10.1097/HJH.0b013e3282efc17d · DOI
  22. Lindroos, 2016, Comparison of acceptability of traditional and novel blood pressure measurement methods, Am J Hypertens, 29, 679, 10.1093/ajh/hpv167 · DOI

Cited by

Sorted by citations

See all 34

Metadata

Authors
Kollias, A., Andreadis, E., Agaliotis, G., Kolyvas, G. N., Achimastos, A., & Stergiou, G. S.
Affiliations
  • Evangelismos Hospital (GR)
  • National and Kapodistrian University of Athens (GR)
Corresponding author
Stergiou, George S.
Venue
Journal of Hypertension
Published
2018-02
Volume
36
Issue
2
Pages
243-249
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2754563049
Cited by
34
References
2
Citations by year
2026: 1 · 2025: 4 · 2024: 7 · 2023: 2 · 2021: 5 · 2020: 5 · 2019: 7 · 2018: 3
FWCI
3.21
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Hypertension (publishedVersion)
  • PubMed (publishedVersion)
Funders
Utah Agricultural Experiment Station
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
nocturnal blood pressure, home blood pressure monitoring, ambulatory blood pressure monitoring, non-dippers, left ventricular mass, carotid intima-media thickness, urinary albumin excretion, untreated hypertension, diagnostic agreement
MeSH terms
Albuminuria, Circadian Rhythm, Cross-Sectional Studies, Female, Heart Ventricles, Humans, Hypertension, Male, Middle Aged, Predictive Value of Tests, Blood Pressure Monitoring, Ambulatory, Carotid Intima-Media Thickness

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review