The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
The optimal night-time home blood pressure monitoring schedule: agreement with ambulatory blood pressure and association with organ damage
Abstract
OBJECTIVE: Night-time home blood pressure (HBP) monitoring has emerged as a feasible, reliable and low-cost alternative to ambulatory blood pressure (ABP) monitoring. This study evaluated the optimal schedule of night-time HBP monitoring in terms of agreement with night-time ABP and association with preclinical target-organ damage. METHODS: Untreated hypertensive adults were evaluated with ABP (24-h) and HBP monitoring (daytime: six days, duplicate morning and evening measurements; night-time: three nights, three-hourly automated measurements/night), and determination of left ventricular mass index, common carotid intima-media thickness and urinary albumin excretion. RESULTS: A total of 94 patients with all nine night-time HBP measurements were analysed [mean age 51.8 ± 11.1 (SD) years, men 57%). By averaging an increasing number of night-time systolic HBP readings, there was a consistent trend towards stronger association of night-time HBP with night-time ABP (correlation coefficients r increased from 0.69 to 0.81), and with target-organ damage indices (for left ventricular mass index r increased from 0.13 to 0.22, carotid intima-media thickness 0.12-0.25, urinary albumin excretion 0.33-0.41). However, no further improvement in the association was observed by averaging more than four to six night-time readings. The diagnostic agreement between HBP and ABP in detecting nondippers was improved by averaging more readings, with a plateau at four readings (single reading: agreement 81%, kappa 0.37; four readings: 88%, 0.49; nine readings: 84%, 0.40). CONCLUSION: A two-night HBP schedule (six readings) appears to be the minimum requirement for a reliable assessment of night-time HBP, which gives reasonable agreement with ABP and association with preclinical organ damage.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Recent technological development of electronic home monitors has enabled automated measurement of home BP during night-time sleep [81,223].”
Citations
Cites
Predictive Role of the Nighttime Blood Pressure
Hansen, T. W., Li, Y., Boggia, J., Thijs, L., Richart, T., & Staessen, J. A. (2011) · Hypertension · doi:10.1161/hypertensionaha.109.133900 · Cited by 597
Nighttime Home Blood Pressure and the Risk of Hypertensive Target Organ Damage
Ishikawa, J., Hoshide, S., Eguchi, K., Ishikawa, S., Shimada, K., Kario, K., & for the Japan Morning Surge-Home Blood Pressure Study Investigators Group (2012) · Hypertension · doi:10.1161/hypertensionaha.112.198101 · Cited by 123
Flagged first, then by citations
Research works printed but not linked: 22
- Mancia, 2013, 2013 ESH/ESC guidelines for the management of arterial hypertension: the Task Force for the management of arterial hypertension of the European Society of Hypertension (ESH) and of the European Society of Cardiology (ESC), J Hypertens, 31, 1281, 10.1097/01.hjh.0000431740.32696.cc · DOI · Paper page
- O’Brien, 2013, European Society of Hypertension position paper on ambulatory blood pressure monitoring, J Hypertens, 31, 1731, 10.1097/HJH.0b013e328363e964 · DOI · Paper page
- Piper, 2015, Diagnostic and predictive accuracy of blood pressure screening methods with consideration of rescreening intervals: a systematic review for the U.S. Preventive Services Task Force, Ann Intern Med, 162, 192, 10.7326/M14-1539 · DOI
- Hansen, 2007, Prognostic superiority of daytime ambulatory over conventional blood pressure in four populations: a meta-analysis of 7,030 individuals, J Hypertens, 25, 1554, 10.1097/HJH.0b013e3281c49da5 · DOI
- Parati, 2008, European Society of Hypertension guidelines for blood pressure monitoring at home: a summary report of the Second International Consensus Conference on Home Blood Pressure Monitoring, J Hypertens, 26, 1505, 10.1097/HJH.0b013e328308da66 · DOI · Paper page
- Stergiou, 2014, Home blood pressure monitoring: primary role in hypertension management, Curr Hypertens Rep, 16, 462, 10.1007/s11906-014-0462-8 · DOI
- Stergiou, 2011, Home blood pressure monitoring in the diagnosis and treatment of hypertension: a systematic review, Am J Hypertens, 24, 123, 10.1038/ajh.2010.194 · DOI
- Stergiou, 2014, Prognosis of white-coat and masked hypertension: International Database of HOme blood pressure in relation to Cardiovascular Outcome, Hypertension, 63, 675, 10.1161/HYPERTENSIONAHA.113.02741 · DOI · Paper page
- Fagard, 2008, Daytime and night-time blood pressure as predictors of death and cause-specific cardiovascular events in hypertension, Hypertension, 51, 55, 10.1161/HYPERTENSIONAHA.107.100727 · DOI · Paper page
- Ushio, 2009, Utility and feasibility of a new programmable home blood pressure monitoring device for the assessment of nighttime blood pressure, Clin Exp Nephrol, 13, 480, 10.1007/s10157-009-0192-4 · DOI
- Stergiou, 2012, Assessment of the diurnal blood pressure profile and detection of nondippers based on home or ambulatory monitoring, Am J Hypertens, 25, 974, 10.1038/ajh.2012.82 · DOI
- Ishikawa, 2014, Assessment of the reductions in night-time blood pressure and dipping induced by antihypertensive medication using a home blood pressure monitor, J Hypertens, 32, 82, 10.1097/HJH.0b013e328365c8a8 · DOI
- Andreadis, 2016, Night-time home versus ambulatory blood pressure in determining target organ damage, J Hypertens, 34, 438, 10.1097/HJH.0000000000000815 · DOI
- Lindroos, 2016, The association between home versus ambulatory nighttime blood pressure and end-organ damage in the general population, J Hypertens, 34, 1730, 10.1097/HJH.0000000000000995 · DOI
- Kollias, 2017, Association of night-time home blood pressure with night-time ambulatory blood pressure and target-organ damage: a systematic review and meta-analysis, J Hypertens, 35, 442, 10.1097/HJH.0000000000001189 · DOI · Paper page
- Ragazzo, 2010, Validation of the Microlife WatchBP O3 device for clinic, home, and ambulatory blood pressure measurement, according to the International Protocol, Blood Press Monit, 15, 59, 10.1097/MBP.0b013e32833531ca · DOI
- Stergiou, 2010, Are there really differences between home and daytime ambulatory blood pressure? Comparison using a novel dual-mode ambulatory and home monitor, J Hum Hypertens, 24, 207, 10.1038/jhh.2009.60 · DOI
- Stergiou, 2007, Validation of the Microlife WatchBP Home device for self home blood pressure measurement according to the International Protocol, Blood Press Monit, 12, 185, 10.1097/MBP.0b013e3280b083ce · DOI
- Stergiou, 1998, Self-monitoring of blood pressure at home: how many measurements are needed?, J Hypertens, 16, 725, 10.1097/00004872-199816060-00002 · DOI · Paper page
- Verberk, 2006, The optimal scheme of self blood pressure measurement as determined from ambulatory blood pressure recordings, J Hypertens, 24, 1541, 10.1097/01.hjh.0000239289.87141.b6 · DOI
- Stergiou, 2007, The optimal schedule for self-monitoring of blood pressure by patients at home, J Hypertens, 25, 1992, 10.1097/HJH.0b013e3282efc17d · DOI
- Lindroos, 2016, Comparison of acceptability of traditional and novel blood pressure measurement methods, Am J Hypertens, 29, 679, 10.1093/ajh/hpv167 · DOI
Cited by
Sorted by citations
Nocturnal Hypertension: New Technology and Evidence
Kario, K. (2018) · Hypertension · doi:10.1161/hypertensionaha.118.10971 · Cited by 298
Parati, G., Stergiou, G. S., Bilo, G., Kollias, A., Pengo, M., Ochoa, J. E., Agarwal, R., Asayama, K., Asmar, R., Burnier, M., et al. (2021) · Journal of Hypertension · doi:10.1097/hjh.0000000000002922 · Cited by 178
Self-citationKario, K., Kanegae, H., Tomitani, N., Okawara, Y., Fujiwara, T., Yano, Y., Hoshide, S., & on behalf of the J-HOP Study Group (2019) · Hypertension · doi:10.1161/hypertensionaha.118.12740 · Cited by 167
Nocturnal blood pressure measured by home devices: evidence and perspective for clinical application
Asayama, K., Fujiwara, T., Hoshide, S., Ohkubo, T., Kario, K., Stergiou, G. S., Parati, G., White, W. B., Weber, M. A., & Imai, Y. (2019) · Journal of Hypertension · doi:10.1097/hjh.0000000000001987 · Cited by 120
Self-citationHosohata, K., Kikuya, M., Asayama, K., Metoki, H., Imai, Y., & Ohkubo, T. (2020) · Clinical and Experimental Hypertension · doi:10.1080/10641963.2020.1779281 · Cited by 16
Metadata
- Authors
- Kollias, A., Andreadis, E., Agaliotis, G., Kolyvas, G. N., Achimastos, A., & Stergiou, G. S.
- Affiliations
- Evangelismos Hospital (GR)
- National and Kapodistrian University of Athens (GR)
- Corresponding author
- Stergiou, George S.
- Venue
- Journal of Hypertension
- Published
- 2018-02
- Volume
- 36
- Issue
- 2
- Pages
- 243-249
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2754563049
- Cited by
- 34
- References
- 2
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 7 · 2023: 2 · 2021: 5 · 2020: 5 · 2019: 7 · 2018: 3
- FWCI
- 3.21
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Hypertension (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Utah Agricultural Experiment Station
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- nocturnal blood pressure, home blood pressure monitoring, ambulatory blood pressure monitoring, non-dippers, left ventricular mass, carotid intima-media thickness, urinary albumin excretion, untreated hypertension, diagnostic agreement
- MeSH terms
- Albuminuria, Circadian Rhythm, Cross-Sectional Studies, Female, Heart Ventricles, Humans, Hypertension, Male, Middle Aged, Predictive Value of Tests, Blood Pressure Monitoring, Ambulatory, Carotid Intima-Media Thickness
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review