CoChat

Obesity and ECG left ventricular hypertrophy

Muiesan, Maria L., Salvetti, Massimo, Di Castelnuovo, Augusto, Paini, Anna, Assanelli, Deodato, Costanzo, Simona, Badilini, Fabio, Vaglio, Martino, Donati, Maria B., Agabiti Rosei, Enrico, de Gaetano, Giovanni, Iacoviello, Licia · 2017 · Journal of Hypertension
Cited by 36

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

AIM: Our aim was to investigate the prevalence and the prognostic significance for fatal and nonfatal cerebrovascular and cardiovascular events of different ECG criteria for left ventricular hypertrophy (LVH) in normal weight, overweight and obese patients in an adult Italian population. METHODS: A total of 18 330 adults (mean age 54 ± 11 years, 55% women, 53% hypertensive patients) were analyzed from the Moli-sani cohort. Obesity was defined using the ATPIII criteria. ECG-LVH was defined according to 2013 ESC-ESH guidelines. RESULTS: The age and sex adjusted prevalence of ECG-LVH did not differ from normal weight patients to class 1-3 obesity patients, when Cornell-voltage criterion was used. In overweight and obese patients, as compared with normal weight patients, a progressively lower prevalence of ECG-LVH was observed when the Sokolow-Lyon index was used, whereas a higher prevalence was shown by using the aVL R-wave voltage (>11 and >5.7 mm) and the Cornell-voltage-QRS duration product. The incidence of cardiovascular events was significantly greater in patients with ECG LVH diagnosis by the Cornell voltage [hazard ratio 1.89, 95% confidence interval (CI) 1.05-3.39] and the Cornell product (hazard ratio 1.87, 95% CI 1.31-2.67). After adjusting for different confounders (age, sex, cigarette, hypertension, hypercholesterolemia, diabetes, income, education, occupational class and physical activity) and for BMI categories, only the Cornell product remained significantly associated with a higher incidence of cardiovascular events (hazard ratio 1.66; 95% CI 1.16-2.38). The predictive significance of different LVH criteria was assessed across BMI categories; after adjusting for confounders, no LVH criteria were significantly associated with an increased risk of cardiovascular events in obese patients; Cornell-product LVH remained an independent predictor of events in normal weight and overweight individuals (hazard ratio 2.63; 95% CI 1.10-6.28 and hazard ratio 2.72; 95% CI 1.52-4.25, respectively). CONCLUSION: Our results confirm that ECG LVH prevalence may differ according to the criteria used across BMI categories in a low cardiovascular risk cohort. The use of different LVH criteria according to BMI categories may improve cardiovascular risk stratification in a general population independently of several confounding factors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/hjh.0000000000001121

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 36

Metadata

Authors
Muiesan, M. L., Salvetti, M., Di Castelnuovo, A., Paini, A., Assanelli, D., Costanzo, S., Badilini, F., Vaglio, M., Donati, M. B., Agabiti Rosei, E., de Gaetano, G., & Iacoviello, L.
Venue
Journal of Hypertension
Published
2017-01
Volume
35
Issue
1
Pages
162-169
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2521742514
Cited by
36
References
1
FWCI
3.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Obesity and ECG left ventricular hypertrophy. https://app.cochat.ai/papers/10.1097/hjh.0000000000001121
The paper
Muiesan, M. L., Salvetti, M., Di Castelnuovo, A., Paini, A., Assanelli, D., Costanzo, S., Badilini, F., Vaglio, M., Donati, M. B., Agabiti Rosei, E., de Gaetano, G., & Iacoviello, L. (2017). Obesity and ECG left ventricular hypertrophy. Journal of Hypertension. https://doi.org/10.1097/hjh.0000000000001121

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.