The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Recommendations and Practical Guidance for performing and reporting validation studies according to the Universal Standard for the validation of blood pressure measuring devices by the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO)
Open accessAbstract
: In the past 30 years, several organizations have developed protocols for clinical validation of blood pressure measuring devices. An international initiative was recently launched by the US Association for the Advancement of Medical Instrumentation (AAMI), the European Society of Hypertension Working Group on Blood Pressure Monitoring (ESH) and the International Organization for Standardization (ISO), aiming to reach consensus on a universal AAMI/ESH/ISO validation standard. The purpose of this statement by the ESH Working Group on Blood Pressure Monitoring is to provide practical guidance for investigators performing validation studies according to the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018), to ensure that its stipulations are meticulously implemented and data are fully reported. Thus, this statement provides: a list of key recommendations for validation studies of intermittent non-invasive automated blood pressure measuring devices according to the AAMI/ESH/ISO Universal Standard; practical stepwise guidance for researchers performing these validation studies; a checklist for authors and reviewers of such studies; an example of a complete validation study report.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Since each unique automated BPMD can have different processes, algorithms and fitting functions to derive BPs (none of which are publicly disclosed), the accuracy of each BPMD needs to be individually determined by comparison to a BP reference standard using a scientifically accepted validation protocol [14, 57, 58].”
From Automated 'oscillometric' blood pressure measuring devices: how they work and what they measure (2022) · cites this paper as [58]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
O'Brien, E. T., Atkins, N., Stergiou, G. S., Karpettas, N., Parati, G., Asmar, R. G., Imai, Y., Wang, J., Mengden, T., & Shennan, A. H. (2010) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3283360e98 · Cited by 609
Self-citationStergiou, G. S., Alpert, B., Mieke, S., Asmar, R., Atkins, N., Eckert, S., Frick, G., Friedman, B., Graßl, T., Ichikawa, T., et al. (2018) · Hypertension · doi:10.1161/hypertensionaha.117.10237 · Cited by 469
Self-citationValidation protocols for blood pressure measuring devices in the 21st century
Stergiou, G. S., Alpert, B. S., Mieke, S., Wang, J., & O'Brien, E. (2018) · The Journal of Clinical Hypertension · doi:10.1111/jch.13294 · Cited by 92
Self-citationStergiou, G. S., Karpettas, N., Atkins, N., & O'Brien, E. T. (2010) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3283360eaf · Cited by 63
Self-citationImproving the accuracy of blood pressure measurement
Stergiou, G. S., Asmar, R. G., Myers, M. G., Palatini, P., Parati, G., Shennan, A. H., Wang, J., & O'Brien, E. T. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001635 · Cited by 56
Self-citationAccuracy of ambulatory blood pressure monitors
Hodgkinson, J., Sheppard, J. P., Heneghan, C. J., Martin, U., Mant, J., Roberts, N. W., & McManus, R. J. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e32835b8d8b · Cited by 45
Self-citationAchieving reliable blood pressure measurements in clinical practice: It's time to meet the challenge
O'Brien, E. T., Dolan, E., & Stergiou, G. S. (2018) · Journal of Clinical Hypertension · doi:10.1111/jch.13323 · Cited by 23
Self-citation[PP.27.03] VALIDATION OF BLOOD PRESSURE MONITORS USING THE AAMI AND ISO PROTOCOLS
Boubouchairopoulou, N., Κόλλιας, Α., Atkins, N., O’Brien, E., & Stergiou, G. S. (2016) · Journal of Hypertension · doi:10.1097/01.hjh.0000492171.90268.34 · Cited by 8
Self-citationReporting of blood pressure monitor validation studies
McManus, R. J., Lacy, P. S., Clark, C., et al. (2018) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000334 · Cited by 5
Self-citation
Flagged first, then by citations
Research works printed but not linked: 1
- O’Brien, 1993, The British Hypertension Society Protocol for the evaluation of blood pressure measuring devices, J Hypertens, 11, S43
Cited by
Sorted by citations
Parati, G., Stergiou, G. S., Bilo, G., Kollias, A., Pengo, M., Ochoa, J. E., Agarwal, R., Asayama, K., Asmar, R., Burnier, M., et al. (2021) · Journal of Hypertension · doi:10.1097/hjh.0000000000002922 · Cited by 178
Self-citationAutomated 'oscillometric' blood pressure measuring devices: how they work and what they measure
Sharman, J. E., Tan, I., Stergiou, G. S., Lombardi, C., Saladini, F., Butlin, M., Padwal, R., Asayama, K., Avolio, A., Brady, T. M., et al. (2022) · Journal of Human Hypertension · doi:10.1038/s41371-022-00693-x · Cited by 84
Self-citationHodgkinson, J. A., Lee, M.-M., Milner, S., Bradburn, P., Stevens, R., Hobbs, F. R., Koshiaris, C., Grant, S., Mant, J., & McManus, R. J. (2020) · British Journal of General Practice · doi:10.3399/bjgp20x710381 · Cited by 52
Self-citationScalise, F., Sole, A., Singh, G., Sorropago, A., Sorropago, G., Ballabeni, C., Maccario, M., Vettoretti, S., Grassi, G., & Mancia, G. (2020) · Journal of Hypertension · doi:10.1097/hjh.0000000000002358 · Cited by 42
Sharman, J. E., Ordunez, P., Brady, T., Parati, G., Stergiou, G., Whelton, P. K., Padwal, R., Olsen, M. H., Delles, C., Schutte, A. E., et al. (2022) · Journal of Human Hypertension · doi:10.1038/s41371-022-00747-0 · Cited by 31
Self-citation
Metadata
- Authors
- Stergiou, G. S., Palatini, P., Asmar, R., Ioannidis, J. P., Kollias, A., Lacy, P., McManus, R. J., Myers, M. G., Parati, G., Shennan, A., Wang, J., & O’Brien, E.
- Affiliations
- National and Kapodistrian University of Athens (GR)
- University of Padua (IT)
- Stanford Medicine (US)
- National Institute for Health and Care Research (GB)
- University of Oxford (GB)
- Sunnybrook Health Science Centre (CA)
- IRCCS Istituto Auxologico Italiano (IT)
- King's College London (GB)
- Corresponding author
- Stergiou, George S.
- ORCID
- Venue
- Journal of Hypertension
- Published
- 2019-03
- Volume
- 37
- Issue
- 3
- Pages
- 459-466
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2904099490
- Semantic Scholar
- 8cd3782131b5a649ca9f85ba5d9ef561cf37d25b
- Cited by
- 218
- References
- 9
- Citations by year
- 2026: 22 · 2025: 33 · 2024: 34 · 2023: 35 · 2022: 37 · 2021: 19 · 2020: 30 · 2019: 6
- FWCI
- 16.63
- Type
- journal article
- Language
- en
- Open access
- green
- discovery.ucl.ac.uk
- Locations
- Journal of Hypertension (publishedVersion)
- PubMed (publishedVersion)
- UCL Discovery (University College London) (submittedVersion)
- BOA (University of Milano-Bicocca) (submittedVersion)
- Research Portal (King's College London) (submittedVersion)
- Funders
- National Institute for Health and Care Research (NIHR200201, NIHR-RP-02-12-015)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- blood pressure measuring devices, device validation, ISO 81060-2:2018, automated blood pressure monitoring, reporting checklist
- MeSH terms
- Blood Pressure, Blood Pressure Determination, Humans, Societies, Medical, Consensus, Validation Studies as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review