Current assessment of pulse wave velocity: comprehensive review of validation studies
The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Carotid-femoral pulse wave velocity (PWV) is considered the gold standard for arterial stiffness assessment in clinical practice. A large number of devices to measure PWV have been developed and validated. We reviewed different validation studies of PWV estimation techniques and assessed their conformity to the Artery Society Guidelines and the American Heart Association recommendations. METHODS: Pubmed and Medline (1995-2017) were searched to identify PWV validation studies. Of the 96 article retrieved, 26 met the inclusion criteria. RESULTS: Several devices had been developed and validated to noninvasively measure arterial stiffness, using applanation tonometry (SphygmoCor, PulsePen), piezoelectric mechanotransducers (Complior), cuff-based oscillometry (Arteriograph, Vicorder and Mobil-O-Graph), photodiode sensors (pOpmètre) and devices assessing brachial-ankle pulse wave velocity and cardiac-ankle PWV. Ultrasound technique and MRI remain confined to clinical research. Good agreement was found with the Artery Society Guidelines. Two studies (Complior, SphygmoCor Xcel) showed best adherence with the guidelines. In Arteriograph, MRI, ultrasound and SphygmoCor Xcel validation studies sample size was smaller than the minimum suggested by the guidelines. High discrepancies between devices were shown in distance estimation: in two studies (Arteriograph, Complior) path length was estimated in conformity to the guidelines. Transit time was calculated using the intersecting tangent method, but in two studies (Vicorder, pOpmètre) best agreement was found using the maximum of the second derivative. Six studies reached the accuracy level 'excellent' defined in the Artery guidelines. CONCLUSION: Method to assess transit time and path length need validation in larger populations. Further studies are required in different risk population to implement clinical applicability of every device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Expert consensus document on arterial stiffness: methodological issues and clinical applications
Laurent, S., Cockcroft, J., Van Bortel, L., Boutouyrie, P., Giannattasio, C., Hayoz, D., Pannier, B., Vlachopoulos, C., Wilkinson, I., Struijker-Boudier, H., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl254 · Cited by 6,077 · cited 1×
“PWV, by definition, results as d over transit time ratio (in m/s) [11].”
BackgroundMancia, G., Fagard, R., Narkiewicz, K., Redón, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2013) · Journal of Hypertension · doi:10.1097/01.hjh.0000431740.32696.cc · Cited by 5,655
Prediction of Cardiovascular Events and All-Cause Mortality With Arterial Stiffness
Vlachopoulos, C., Aznaouridis, K., & Stefanadis, C. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.10.061 · Cited by 4,165 · cited 1×
“Moreover, aortic stiffness has gained independent predictive value for fatal and nonfatal cardiovascular events in hypertensive patients [1,5,6], and could thus reclassify intermediate risk patients into higher or lower cardiovascular risk [1,7,8].”
BackgroundLaurent, S., Boutouyrie, P., Asmar, R., Gautier, I., Laloux, B., Guize, L., Ducimetiere, P., & Benetos, A. (2001) · Hypertension · doi:10.1161/01.hyp.37.5.1236 · Cited by 3,856 · cited 2×
“Complior has been used extensively in epidemiologic studies in Europe and formed much of the available data, demonstrating the significant and independent contribution of PWV to cardiovascular morbidity and mortality [5,29,30].”
BackgroundMethodImpact of Aortic Stiffness on Survival in End-Stage Renal Disease
Blacher, J., Guerin, A. P., Pannier, B., Marchais, S. J., Safar, M. E., & London, G. M. (1999) · Circulation · doi:10.1161/01.cir.99.18.2434 · Cited by 2,138 · cited 2×
“Both noninvasively and PWVINV measurements were considered as reference method [54].”
BackgroundMethodVan Bortel, L. M., Laurent, S., Boutouyrie, P., Chowienczyk, P., Cruickshank, J. K., De Backer, T., Filipovsky, J., Huybrechts, S., Mattace-Raso, F. U. S., Protogerou, A. D., et al. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e32834fa8b0 · Cited by 2,010 · cited 3×
“80% of carotid–femoral direct distance is the most accurate way to assess path length (the ‘80% method’) [4,60].”
BackgroundMethodBoutouyrie, P., Tropeano, A. I., Asmar, R., Gautier, I., Benetos, A., Lacolley, P., & Laurent, S. (2002) · Hypertension · doi:10.1161/hy0102.099031 · Cited by 1,745 · cited 1×
“Complior has been used extensively in epidemiologic studies in Europe and formed much of the available data, demonstrating the significant and independent contribution of PWV to cardiovascular morbidity and mortality [5,29,30].”
MethodYAMASHINA, A., TOMIYAMA, H., TAKEDA, K., TSUDA, H., ARAI, T., HIROSE, K., KOJI, Y., HORI, S., & YAMAMOTO, Y. (2002) · Hypertension Research · doi:10.1291/hypres.25.359 · Cited by 1,623 · cited 9×
“PWVINV assessment was compared with SphygmoCor [15,16], Mobil-O-Graph [32] (and the ARCSolver algorithm [16]), Arteriograph [37], ba-PWV [41], Doppler ultrasound [52] and MRI [55,59].”
BackgroundMethodResultInfluentialCruickshank, K., Riste, L., Anderson, S. G., Wright, J. S., Dunn, G., & Gosling, R. G. (2002) · Circulation · doi:10.1161/01.cir.0000033824.02722.f7 · Cited by 1,531 · cited 2×
“With the ‘simultaneous technique’, two microphones are placed, respectively, to the left side of the neck (to insonate the left subclavian artery) and on the abdomen (to insonate the abdominal aorta above the bifurcation) and record simultaneously the pressure wave [51].”
BackgroundMethodTownsend, R. R., Wilkinson, I. B., Schiffrin, E. L., Avolio, A. P., Chirinos, J. A., Cockcroft, J. R., Heffernan, K. S., Lakatta, E. G., McEniery, C. M., Mitchell, G. F., et al. (2015) · Hypertension · doi:10.1161/hyp.0000000000000033 · Cited by 1,473 · cited 7×
“A first source of inaccuracy is body surface measurements, which may not represent the true aortic and arterial length [9,10].”
BackgroundMethodInfluential
Cited by
How to Measure Arterial Stiffness in Humans
Segers, P., Rietzschel, E. R., & Chirinos, J. A. (2020) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.119.313132 · Cited by 248
Arterial stiffness and vascular aging: mechanisms, prevention, and therapy
Herzog, M. J., Müller, P., Lechner, K., Stiebler, M., Arndt, P., Kunz, M., Ahrens, D., Schmeißer, A., Schreiber, S., & Braun-Dullaeus, R. C. (2025) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-025-02346-0 · Cited by 189
“28,156 The latter is clinically very well validated and one of the most reliable devices for measuring PWV. 156,331 The simultaneous version uses the foot-to-foot method, which illustrates the beginning of the pressure curve rise at the end of diastole as a foot.”
Ning, R., Li, Y., Du, Z., Li, T., Sun, Q., Lin, L., Xu, Q., Duan, J., & Sun, Z. (2021) · Redox Biology · doi:10.1016/j.redox.2021.102113 · Cited by 96
“PWV is the gold standard used for evaluating arterial stiffness [37].”
Metadata
- Authors
- Milan, A., Zocaro, G., Leone, D., Tosello, F., Buraioli, I., Schiavone, D., & Veglio, F.
- Venue
- Journal of Hypertension
- Published
- 2019-08
- Volume
- 37
- Issue
- 8
- Pages
- 1547-1557
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2922842315
- Cited by
- 236
- References
- 65
- FWCI
- 13.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.