OBJECTIVE: To evaluate ambulatory blood pressure monitoring (ABPM) parameters in a broad sample of high-risk hypertensive patients. METHODS: The Spanish Society of Hypertension is developing a nationwide project in which more than 900 physicians send ABPM registries and corresponding clinical records to a central database via www.cardiorisc.com. Between June 2004 and July 2005 a 20 000-patient database was obtained; 17 219 were valid for analysis. RESULTS: We identified 6534 patients with high cardiovascular risk according to the 2003 European Society of Hypertension/European Society of Cardiology guidelines stratification score. Office blood pressure (BP) was 158.8/89.9 mmHg and 24-h BP was 135.8/77.0 mmHg. Patients with grade 3 BP in the office showed ambulatory systolic BP values less than 160 mmHg in more than 80%. A non-dipping pattern was observed in 3836 cases (58.7%), whereas this abnormality was present in 47.9% of patients with low-to-moderate risk [odds ratio (OR) 1.54; 95% confidence interval (CI) 1.45-1.64]. The prevalence of non-dippers was higher as ambulatory BP increased ( approximately 70% when 24-h systolic BP > 155 mmHg) and was similar in both groups. At the lowest levels of BP (24-h systolic BP < 135 mmHg) a non-dipping pattern was more prevalent in high-risk cases (56.6 versus 45.7%; OR 1.51; 95% CI 1.40-1.64). CONCLUSION: There was a remarkable discrepancy between office and ambulatory BP in high-risk hypertensive patients. The prevalence of a non-dipper BP pattern was almost 60%. In the lowest levels of ambulatory BP, high-risk patients showed a higher prevalence of non-dipping BP than lower-risk cases. These observations support the recommendation of a wider use of ABPM in high-risk hypertensive patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/hjh.0b013e32809874a2

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 123

Metadata

Authors
Gorostidi, M., Sobrino, J., Segura, J., Sierra, C., de la Sierra, Á., Hernández del Rey, R., Vinyoles, E., Galcerán, J. M., López-Eady, M. D., Marín, R., Banegas, J. R., Sarría, A., Coca, A., & Ruilope, L. M.
Venue
Journal of Hypertension
Published
2007-05
Volume
25
Issue
5
Pages
977-984
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2026798195
Cited by
123
References
7
FWCI
7.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ambulatory blood pressure monitoring in hypertensive patients with high cardiovascular risk: a cross-sectional analysis of a 20 000-patient database in Spain. https://app.cochat.ai/papers/10.1097/hjh.0b013e32809874a2
The paper
Gorostidi, M., Sobrino, J., Segura, J., Sierra, C., de la Sierra, Á., Hernández del Rey, R., Vinyoles, E., Galcerán, J. M., López-Eady, M. D., Marín, R., Banegas, J. R., Sarría, A., Coca, A., & Ruilope, L. M. (2007). Ambulatory blood pressure monitoring in hypertensive patients with high cardiovascular risk: a cross-sectional analysis of a 20 000-patient database in Spain. Journal of Hypertension. https://doi.org/10.1097/hjh.0b013e32809874a2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.