CoChat

A new method for assessing 24-h blood pressure variability after excluding the contribution of nocturnal blood pressure fall

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Abstract

Objectives To assess quantitatively the relationship between nocturnal blood pressure (BP) fall and 24-h BP variability; to propose a new method for computing 24-h BP variability, devoid of the contribution from nocturnal BP fall; and to verify the clinical value of this method. Methods and results We analysed 3863 ambulatory BP recordings, and computed: (1) the standard deviation (SD) of 24-h BP directly from all individual readings and as a weighted mean of daytime and night-time SD (wSD); and (2) the size of nocturnal BP fall. Left ventricular mass index (LVMI) was assessed by echocardiography in 339 of the patients. The 24-h SD of BP was significantly greater than the 24-h wSD. Nocturnal BP fall was strongly and directly related to 24-h SD, the relationship with 24-h wSD being much weaker and inverse. The difference between SD and wSD was almost exclusively determined by the size of nocturnal BP fall. wSD of systolic BP was significantly related to LVMI, while 24-h SD was not. Conclusion Conventional 24-h SD of BP is markedly influenced by nocturnal BP fall. The weighted 24-h SD of BP removes the mathematical interference from night-time BP fall and correlates better with end-organ damage, therefore it may be considered as a simple index of 24-h BP variability superior to conventional 24-h SD.

Overview

Integrity signals

Registry

Crossref · 10.1097/hjh.0b013e32829c6a60

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 22 references

Cited by

See all 246

Metadata

Authors
Bilo, G., Giglio, A., Styczkiewicz, K., Caldara, G., Maronati, A., Kawecka-Jaszcz, K., Mancia, G., & Parati, G.
Affiliations
  • Jagiellonian University (PL)
  • IRCCS Istituto Auxologico Italiano (IT)
Corresponding author
Parati, Gianfranco
Venue
Journal of Hypertension
Published
2007-10
Volume
25
Issue
10
Pages
2058-2066
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2076000810
Cited by
246
References
22
Citations by year
2026: 5 · 2025: 13 · 2024: 16 · 2023: 12 · 2022: 15 · 2021: 12 · 2020: 15 · 2019: 15 · 2018: 17 · 2017: 20 · 2016: 19 · 2015: 25 · 2014: 19 · 2013: 13 · 2012: 8
FWCI
3.29
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Hypertension (publishedVersion)
  • PubMed (publishedVersion)
  • BOA (University of Milano-Bicocca) (submittedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
Keywords
24-hour blood pressure variability, nocturnal blood pressure dipping, ambulatory blood pressure monitoring, weighted standard deviation, left ventricular mass index, target organ damage, hypertension, systolic blood pressure
MeSH terms
Adult, Aged, Analysis of Variance, Blood Pressure, Circadian Rhythm, Echocardiography, Female, Heart Ventricles, Humans, Hypertension, Male, Middle Aged, Blood Pressure Monitoring, Ambulatory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A new method for assessing 24-h blood pressure variability after excluding the contribution of nocturnal blood pressure fall. https://app.cochat.ai/papers/10.1097/hjh.0b013e32829c6a60
The paper
Bilo, G., Giglio, A., Styczkiewicz, K., Caldara, G., Maronati, A., Kawecka-Jaszcz, K., Mancia, G., & Parati, G. (2007). A new method for assessing 24-h blood pressure variability after excluding the contribution of nocturnal blood pressure fall. Journal of Hypertension. https://doi.org/10.1097/hjh.0b013e32829c6a60

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.