CoChat

Reproducibility of the circadian blood pressure pattern in 24-h versus 48-h recordings: the Spanish Ambulatory Blood Pressure Monitoring Registry

Rey, Raquel Hernández-del, Martin-Baranera, Montserrat, Sobrino, Javier, Gorostidi, Manuel, Vinyoles, Ernest, Sierra, Cristina, Segura, Julian, Coca, Antonio, Ruilope, Luis Miguel · 2007 · Journal of Hypertension
Cited by 65

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: To assess the reproducibility of the circadian blood pressure (BP) pattern over a 48-h period by comparing the first 24 h of ambulatory blood pressure monitoring (ABPM) with the following 24 h and with the mean over 48 h. PATIENTS AND METHODS: Patients undergoing 48-h ABPM within the National ABPM Registry of the Spanish Society of Hypertension, based on 800 Spacelabs 90207 monitors distributed throughout Spain in hypertension units and primary healthcare centres, were included. Between June 2004 and September 2005, 611 valid 48-h ABPM recordings were obtained, 235 corresponded to patients without antihypertensive treatment. RESULTS: The percentages of patients classified as non-dipper for the first 24 h, the second 24 h and the 48-h average were 47, 50 and 48%, respectively. When the first and second 24-h periods were compared, 147 (24%) subjects switched from dipper (D) to non-dipper (ND) or vice-versa. When the first 24-h period was compared to the 48-h average, 66 (11%) subjects switched patterns. The proportions were similar separately for systolic blood pressure (SBP) and diastolic blood pressure (DBP) and between treated and untreated patients. In subjects with poor ABPM reproducibility, night-to-day ratios were of an intermediate value between those of subjects always classified as D or ND. CONCLUSION: Categorization of D or ND based on a single 24-h ABPM is moderately reproducible, since one out of every five patients change profile over the following 24 h. Nevertheless, the use of 48-h ABPM in clinical practice should be assessed according to cost-effectiveness criteria. Night-to-day ratios may be helpful in identifying patients with a stable profile.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/hjh.0b013e3282effed1

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Rey, R. H.-D., Martin-Baranera, M., Sobrino, J., Gorostidi, M., Vinyoles, E., Sierra, C., Segura, J., Coca, A., & Ruilope, L. M.
Venue
Journal of Hypertension
Published
2007-12
Volume
25
Issue
12
Pages
2406-2412
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2055421770
Cited by
65
References
5
FWCI
3.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.