CoChat

Predictive value of ambulatory heart rate in the Japanese general population: the Ohasama study

Hozawa, Atsushi, Inoue, Ryusuke, Ohkubo, Takayoshi, Kikuya, Masahiro, Metoki, Hirohito, Asayama, Kei, Hara, Azusa, Hirose, Takuo, Kanno, Atsuhiro, Obara, Taku, Hoshi, Haruhisa, Hashimoto, Junichiro, Totsune, Kazuhito, Satoh, Hiroshi, Imai, Yutaka · 2008 · Journal of Hypertension
Cited by 78

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Resting heart rate can predict cardiovascular disease mortality or all-cause mortality. Because of the effect of the alert reaction, heart rates measured out-of-office should have better predictive power than those obtained at clinics. However, only a few studies have described the relationship between heart rate measured by ambulatory blood pressure monitoring devices and cardiovascular disease prediction. METHODS: We studied 1444 individuals from the Japanese general population who did not have a history of cardiovascular diseases including arrhythmia. We used multiple adjusted Cox proportional hazards to calculate the mortality risk of daytime heart rate, night-time heart rate, and the day-night heart rate dip ratio [day-night heart rate dip ratio = (daytime heart rate--night-time heart rate)/daytime heart rate x 100]. RESULTS: After 12 years of follow-up, 101, 195, and 296 participants died due to cardiovascular diseases, noncardiovascular diseases, and all causes, respectively. As shown by others, neither daytime nor night-time heart rate predicted cardiovascular disease mortality, whereas both predicted noncardiovascular disease mortality. The day-night heart rate dip ratio was significantly related to all-cause mortality. When night-time heart rate and day-night heart rate dip ratio were simultaneously included into the same Cox model, only night-time heart rate significantly and independently predicted all-cause mortality (relative hazard per 10 bpm increase = 1.29, 95% confidence interval, 1.07-1.54). CONCLUSION: Night-time heart rate value seems to have the most important predictor of all-cause mortality among ambulatory heart rate parameters in this population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/hjh.0b013e3283041172

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 78

Metadata

Authors
Hozawa, A., Inoue, R., Ohkubo, T., Kikuya, M., Metoki, H., Asayama, K., Hara, A., Hirose, T., Kanno, A., Obara, T., Hoshi, H., Hashimoto, J., Totsune, K., Satoh, H., & Imai, Y.
Venue
Journal of Hypertension
Published
2008-08
Volume
26
Issue
8
Pages
1571-1576
ISSN
0263-6352 (ISSN-L)
OpenAlex
W1989676681
Cited by
78
References
3
FWCI
3.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.