The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Home blood pressure telemonitoring improves hypertension control in general practice. The TeleBPCare study
Abstract
BACKGROUND: Self blood pressure monitoring at home may improve blood pressure control and patients' compliance with treatment, but its implementation in daily practice faces difficulties. Teletransmission facilities may offer a more efficient approach to long-term home blood pressure monitoring. METHODS: Twelve general practitioners screened 391 consecutive uncontrolled mild-moderate hypertensive patients (80% treated), 329 of whom (58 +/- 11 years, 54% men) were randomized to either usual care on the basis of office blood pressure (group A, n = 113) or to integrated care on the basis of teletransmitted home blood pressure (group B, n = 216). Twenty-four-hour ambulatory blood pressure monitoring was performed at baseline and after 6 months, during which treatment was optimized according to either office (group A) or home (group B) blood pressure values. We compared differences between groups in the rate of daytime ambulatory blood pressure normalization (<130/80 mmHg), need of treatment changes during follow-up, quality of life scores, and healthcare costs. RESULTS: Baseline office blood pressures were 149 +/- 12/89 +/- 9 and 148 +/- 13/89 +/- 7 mmHg in groups A (n = 111) and B (n = 187) respectively, the corresponding daytime values being 140 +/- 11/84 +/- 8 and 139 +/- 11/84 +/- 8 mmHg. The percentage of daytime blood pressure normalization was higher in group B (62%) than in group A (50%) (P < 0.05). There were less frequent treatment changes in group B than in group A (9 vs. 14%, P < 0.05). Quality of life tended to be higher and costs lower in group B. CONCLUSION: Patients' management based on home blood pressure teletransmission led to a better control of ambulatory blood pressure than with usual care, with a more regular treatment regimen.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A smartphone application from the European Society of Hypertension (ESH CARE app) has been validated and continuously updated.”
From São Paulo call to action for the prevention and control of high blood pressure: 2020 (2019) · cites this paper as [65]
Citations
Cites
2013 ESH/ESC Guidelines for the management of arterial hypertension
Authors Task Force Members, Mancia, G., Fagard, R., Narkiewicz, K., Redon, J., Zanchetti, A., Böhm, M., Christiaens, T., Cífková, R., Backer, G. D., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht151 · Cited by 13,739
Self-citationGlobal burden of hypertension: analysis of worldwide data
Kearney, P. M., Whelton, M., Reynolds, K., Muntner, P., Whelton, P. K., & He, J. (2005) · The Lancet · doi:10.1016/s0140-6736(05)17741-1 · Cited by 8,698
2007 Guidelines for the Management of Arterial Hypertension
Mancia, G., Backer, G. D., Dominiczak, A. F., Cífková, R., Fagard, R. H., Germanò, G., Grassi, G. M., Heagerty, A. M., Kjeldsen, S. E., Laurent, S., et al. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e3281fc975a · Cited by 5,870
Self-citationSelected major risk factors and global and regional burden of disease
Ezzati, M., Lopez, A. D., Rodgers, A., Vander Hoorn, S., & Murray, C. J. (2002) · The Lancet · doi:10.1016/s0140-6736(02)11403-6 · Cited by 3,594
Sega, R., Facchetti, R., Bombelli, M., Cesana, G., Corrao, G., Grassi, G., & Mancia, G. (2005) · Circulation · doi:10.1161/01.cir.0000160923.04524.5b · Cited by 1,009
Self-citationBobrie, G. (2004) · JAMA · doi:10.1001/jama.291.11.1342 · Cited by 842
Parati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Self-citationOhkubo, T., Imai, Y., Tsuji, I., Nagai, K., Kato, J., Kikuchi, N., Nishiyama, A., Aihara, A., Sekino, M., Kikuya, M., et al. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816070-00010 · Cited by 746
Blood pressure control by home monitoring: meta-analysis of randomised trials
Cappuccio, F. P., Kerry, S., Forbes, L. J. L., & Donald, A. (2004) · BMJ · doi:10.1136/bmj.38121.684410.ae · Cited by 503
Fagard, R. H., Broeke, C. V. D., & Cort, P. D. (2005) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001903 · Cited by 321
Cited by
Sorted by citations
Items 101–166 of 166
Salisbury, C., O’Cathain, A., Thomas, C., Edwards, L., Montgomery, A. A., Hollinghurst, S. P., Large, S., Nicholl, J. P., Pope, C. J., Rogers, A. E., et al. (2017) · Programme Grants for Applied Research · doi:10.3310/pgfar05010 · Cited by 9
Parati, G., Ochoa, J. E., Ramos-Galarza, C., Hoshide, S., Lonati, L. M., & Bilo, G. (2010) · Therapeutic Advances in Cardiovascular Disease · doi:10.1177/1753944710380228 · Cited by 9
Self-citationTwo Self-management Interventions to Improve Hypertension Control: A Randomized Trial
Elliott, W. J. (2010) · Yearbook of Cardiology · doi:10.1016/s0145-4145(09)79793-x · Cited by 9
Development and Preliminary Feasibility of an Automated Hypertension Self-Management System
Irizarry, T., Allen, M., Suffoletto, B. P., Einhorn, J., Burke, L. E., Kamarck, T. W., Rollman, B. L., & Muldoon, M. F. (2018) · The American Journal of Medicine · doi:10.1016/j.amjmed.2018.04.038 · Cited by 9
Telemonitoring and remote counseling in hypertensive patients. Looking for new ways to do old jobs
Васильевич, И. М., Звартау, Н. Э., Emelyanov, I. V., & Конради, А. О. (2019) · Arterial’naya Gipertenziya (Arterial Hypertension) · doi:10.18705/1607-419x-2019-25-4-337-356 · Cited by 9
Moosa, A. S., Seng, J. J. B., & Ng, C. J. (2025) · Journal of Medical Internet Research · doi:10.2196/75551 · Cited by 8
2022 Thai Hypertension Society guidelines on home blood pressure monitoring
Kunanon, S., Roubsanthisuk, W., Chattranukulchai, P., Sangwatanaroj, S., Ophascharoensuk, V., Sitthisook, S., & Sukonthasarn, A. (2022) · Journal of Clinical Hypertension · doi:10.1111/jch.14569 · Cited by 8
Muneer, S., Okpechi, I. G., Ye, F., Zaidi, D., Tinwala, M. M., Hamonic, L. N., Ghimire, A., Sultana, N., Slabu, D., Khan, M., et al. (2022) · Canadian Journal of Kidney Health and Disease · doi:10.1177/20543581221106248 · Cited by 9
Elliott, W. J. (2010) · Yearbook of Cardiology · doi:10.1016/s0145-4145(10)79843-9 · Cited by 7
Lee, C.-H., & Chang, B.-Y. (2015) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2015.0045 · Cited by 7
Llamado a la acción de San Pablo para la prevención y el control de la hipertensión arterial, 2020
Campbell, N. R. C., Schutte, A. E., Varghese, C. V., Ordúñez, P., Zhang, X., Khan, T., Sharman, J. E., Whelton, P. K., Parati, G., Weber, M. A., et al. (2021) · Revista Panamericana de Salud Pública · doi:10.26633/rpsp.2021.26 · Cited by 9
Self-citationRemote health monitoring system in a rural population: Challenges and opportunities
Minoi, J.-L., & Yeo, A. W. (2014) · IEEE-EMBS Conference on Biomedical Engineering and Sciences · doi:10.1109/iecbes.2014.7047641 · Cited by 6
TAMURA, T., & Kimura, Y. (2015) · Biomedical Engineering Letters · doi:10.1007/s13534-015-0172-4 · Cited by 6
Home blood pressure for the management of hypertension: will it become the new standard of practice?
Krakoff, L. R. (2011) · Expert Review of Cardiovascular Therapy · doi:10.1586/erc.11.64 · Cited by 7
Choi, W. S., Shin, I., & Yang, J. (2019) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2019.0205 · Cited by 6
Simenyura, S. S., & Sizova, Z. M. (2022) · Meditsinskiy sovet = Medical Council · doi:10.21518/2079-701x-2021-21-2-16-25 · Cited by 6
Krakoff, L. R. (2015) · Springer eBooks · doi:10.1007/978-3-319-22771-9_17 · Cited by 6
Blood pressure telemonitoring and remote counseling of hypertensive patients: pros and cons
Васильевич, И. М., Звартау, Н. Э., Конради, А. О., & Shlyakhto, E. V. (2020) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2020-4066 · Cited by 6
Miranda, R. D., Brandão, A. A., Barroso, W. K. S., Gomes, M. A. M., Barbosa, E. C. D., Ribeiro, L. P. D. S., Aguilar, C. A., Silveira, F. S., Gomes, C. D. M. R., Epelman, A., et al. (2023) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20220863 · Cited by 5
Parati, G., Ochoa, J. E., Postel‐Vinay, N., Pellegrini, D., Torlasco, C., Omboni, S., & McManus, R. J. (2019) · Updates in hypertension and cardiovascular protection · doi:10.1007/978-3-030-23065-4_11 · Cited by 5
Self-citationA pilot study of hypertension management using a telemedicine treatment approach
Wijkman, M., Carlsson, M., Darwiche, G., & Nystrom, F. H. (2020) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000413 · Cited by 5
A monitorização residencial da pressão arterial e o controle de um grupo de hipertensos
da Silva, G. C. A., & Pierin, Â. M. G. (2012) · Revista da Escola de Enfermagem da USP · doi:10.1590/s0080-62342012000400020 · Cited by 5
Moulaei, K., Roudsari, P. P., Sardoo, A. S., Hosseini, M., Anabestani, M., Moulaei, R., Sabet, B., & Afrash, M. R. (2024) · Journal of Telemedicine and Telecare · doi:10.1177/1357633x241291222 · Cited by 4
Rech, J., Postel‐Vinay, N., Vercamer, V., de Villèle, P., & Steichen, O. (2024) · Journal of Hypertension · doi:10.1097/hjh.0000000000003861 · Cited by 3
Home blood pressure telemonitoring in the Netherlands: a pilot study in GP practices
van Steenkiste, J., Verberk, I., Versmissen, J., Dohmen, D., & Jainandunsing, S. (2024) · BMC Digital Health · doi:10.1186/s44247-024-00072-1 · Cited by 3
Martinengo, L., Ha, N. H. L., Tay, E. Y. J., Tong, S. C., & Sevdalis, N. (2025) · JMIR Research Protocols · doi:10.2196/72942 · Cited by 3
Clinical Significance of Home Blood Pressure and Its Possible Practical Application
Imai, Y. (2012) · Journal of the Korean Society of Hypertension · doi:10.5646/jksh.2012.18.1.1 · Cited by 3
Kovell, L. C., Bothwick, V., McCabe, P., Juraschek, S. P., Meng, Y., Revoori, R., Pena, S., Schoenthaler, A., Adhikari, S., & Dodson, J. A. (2024) · Journal of Cardiopulmonary Rehabilitation and Prevention · doi:10.1097/hcr.0000000000000911 · Cited by 3
Mizuno, T., Nabetani, N., Yamashita, N., Matsumoto, C., Yasuda, Y., Nagamatsu, T., & Umemura, N. (2016) · Clinical Case Reports · doi:10.1002/ccr3.702 · Cited by 3
Mesures de la pression artérielle
Amar, J., Bénétos, A., Blacher, J., Bobrie, G., Chamontin, B., Girerd, X. J., Halimi, J., Herpin, D., Mounier‐Véhier, C., Mourad, J., et al. (2012) · Médecine des Maladies Métaboliques · doi:10.1016/s1957-2557(12)70431-5 · Cited by 3
Chamado à ação de São Paulo para prevenção e controle da hipertensão arterial, 2020
Campbell, N. R. C., Schutte, A. E., Varghese, C. V., Ordúñez, P., Zhang, X., Khan, T., Sharman, J. E., Whelton, P. K., Parati, G., Weber, M. A., et al. (2021) · Revista Panamericana de Salud Pública · doi:10.26633/rpsp.2021.27 · Cited by 3
Self-citationHome (Self) Monitoring of Blood Pressure
Parati, G., & Ochoa, J. E. (2015) · Springer eBooks · doi:10.1007/978-3-319-22771-9_2 · Cited by 3
Self-citationHome Blood Pressure Monitoring in Hypertension
Parati, G., Ochoa, J. E., & Bilo, G. (2012) · Springer eBooks · doi:10.1007/978-88-470-2601-8_9 · Cited by 2
Self-citationManagement de l’hypertension en télémédecine : étude de faisabilité et résultats sur 100 patients
Dary, P. (2012) · European Research in Telemedicine / La Recherche Européenne en Télémédecine · doi:10.1016/j.eurtel.2012.09.003 · Cited by 2
Home Versus Ambulatory Blood Pressure Monitoring
O'Brien, E. T., de la Sierra, Á., McManus, R. J., Mihailidou, A. S., Muntner, P., Myers, M. G., Stergiou, G. S., Parati, G., & Manios, E. D. (2019) · Updates in hypertension and cardiovascular protection · doi:10.1007/978-3-030-23065-4_15 · Cited by 2
Self-citationVerghese, B. G., Kashinath, S. K., Kiwalkar, S., & Henderson, C. M. (2018) · Cureus · doi:10.7759/cureus.3118 · Cited by 2
Mukhopadhyay, A., Swathi, S., & Srinidhi, A. (2019) · IEEE Global Conference for Advancement in Technology (GCAT) · doi:10.1109/gcat47503.2019.8978463 · Cited by 2
The Citizen Telehealth Care Service model in Taipei: A case study
Chen, M., Chiang, S.-J., Lee, J.-S., & Yu, E. W.-R. (2012) · IEEE International Conference on e-Health Networking, Applications and Services (Healthcom) · doi:10.1109/healthcom.2012.6379447 · Cited by 1
Sadeghi‐Bazargani, H., Safiri, S., Farahbakhsh, M., Habibzadeh, S., Nikniaz, A., Kousha, A., Jayasinghe, H., & Yousefi, A. (2015) · Journal of Archives in Military Medicine · doi:10.5812/jamm.3(2)2015.26664 · Cited by 1
Mizuno, T., Matsumoto, C., Nabetani, N., Yasuda, Y., Nagamatsu, T., & Umemura, N. (2014) · Patient Preference and Adherence · doi:10.2147/ppa.s69016 · Cited by 1
Comparing the therapeutic merits of angiotensin receptor blockers
Dolan, E., & O’Brien, E. (2016) · Journal of Hypertension · doi:10.1097/hjh.0000000000000940 · Cited by 1
Bilger, M., Koong, A. Y. L., Phoon, I. K. Y., Tan, N. C., Bahadin, J., Bairavi, J., Batcagan-Abueg, A. P. M., & Finkelstein, E. A. (2021) · JMIR Research Protocols · doi:10.2196/27496 · Cited by 1
Uncertainty in Meta-Analysis: Bridging the Divide Between Ideal and Available Extracted Data
Rizzo, S. (2015) · Cited by 1
A holistic ecosystem for rural mHealth applications and lesson learnt
Minoi, J.-L., Suhaili, M. R., & Yeo, A. W. (2014) · IEEE-EMBS Conference on Biomedical Engineering and Sciences · doi:10.1109/iecbes.2014.7047460 · Cited by 1
Mancia, G., & Fagard, R. H. (2013) · Cited by 1
Self-citationNew trends in BP home monitoring
Chetan, M., & Moldovan, C. (2017) · International Symposium on Advanced Topics in Electrical Engineering · doi:10.1109/atee.2017.7905140 · Cited by 2
Middeke, M. (2020) · Springer eBooks · doi:10.1007/978-3-662-60611-7_26 · Cited by 1
de la Cruz, M. E. M. P., Zegarra, C. I. L., Vega, R. M. B., Sime, C. L. T., Narro, J. B. S., Peñaranda, L. A. F., & Morán, R. C. D. (2023) · EAI Endorsed Transactions on Pervasive Health and Technology · doi:10.4108/eetpht.9.4215 · Cited by 1
Changes in quality of life in hypertensive patients during home blood pressure telemonitoring
Klocek, M., Brzozowska-Kiszka, M., Rajzer, M. W., & Kawecka−Jaszcz, K. (2010) · Jagiellonian University Repository (Jagiellonian University)
Mancia, G., & Fagard, R. H. (2016)
Self-citationKontrola ciśnienia tętniczego w warunkach domowych
Parati, G., Bilo, G., Kjeldsen, S. E., & Mancia, G. (2009) · Choroby Serca i Naczyń
Self-citationGiokas, K., Costarides, V., & Koutsouris, D. (2016) · Advances in healthcare information systems and administration book series · doi:10.4018/978-1-4666-9861-1.ch004
How to Improve Patients’ Adherence to Antihypertensive Therapy: A Simple Solution for a Big Trouble
Tocci, G., Presta, V., & Volpe, M. (2018) · American Journal of Hypertension · doi:10.1093/ajh/hpy179
Normal Variations in Blood Pressure in Ambulatory Blood Pressure Measurements
Mıstık, S., Goktas, K., Ünalan, D., Oğuzhan, A., & Tokgöz, B. (2021) · Eurasian Journal of Family Medicine · doi:10.33880/ejfm.2021100101
Sadeghi‐Bazargani, H., Safiri, S., Farahbakhsh, M., Habibzadeh, S., Nikniaz, A., Kousha, A., Jayasinghe, H., & Yousefi, A. (2015) · Journal of Archives in Military Medicine · doi:10.5812/jamm.26664
(2012) · Elsevier eBooks · doi:10.1016/b978-0-323-08373-7.00017-0
Elliott, W. J. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4377-1366-4.00009-3
Management of Blood Pressure Control: At the Cutting Edge
McEvoy, L. (2015) · EMJ Cardiology · doi:10.33590/emjcardiol/10311935
Earlier identification of hypertensive events in a telemonitoring system
Do, E., Lavu, S., Kum, H., & Mortazavi, B. J. (2023) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn58485.2023.10330992
Study and Analysis of IoT-Based Telemedicine and Remote Patient Monitoring
Kumar, R. K., & Sobin, C. C. (2024) · Advances in IT standards and standardization research (AISSR) book series/Advances in IT standards and standardization research series · doi:10.4018/979-8-3693-1686-3.ch005 · Cited by 1
Evaluation of an Email Blood Pressure Measurement Outreach Program
Green, B. B., Hansell, L. D., Hsu, C. W., Jones, T. E., Luce, C., Ralston, J. D., Munson, S. A., Davis, B., Wright, T., & Anderson, M. L. (2025) · American Journal of Hypertension · doi:10.1093/ajh/hpaf206
Ni, X., Xue, H., Fan, L., Li, M., Yang, J., & Du, W. D. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-02064-5 · Cited by 1
Self-monitoring blood pressure in patients with hypertension: who self-monitors and why?
Grant, S. (2014) · University of Birmingham Institutional Research Archive (University of Birmingham)
Ma, Y., zhang, X., Shi, J., Guo, C., Tian, C., Wan, Z., Li, Y., Li, Y., Guo, L., Lang, Y., et al. (2026) · doi:10.2196/preprints.102956
Ma, Y., zhang, X., Li, Y., Wan, Z., Guo, L., Shi, J., Lang, Y., & sun, W. (2026) · Journal of Medical Internet Research · doi:10.2196/99321
Metadata
- Authors
- Parati, G., Omboni, S., Albini, F., Piantoni, L., Giuliano, A., Revera, M., Illyes, M., & Mancia, G.
- Affiliations
- IRCCS Istituto Auxologico Italiano (IT)
- Italian Institute of Telemedicine (IT)
- Corresponding author
- Parati, Gianfranco
- Venue
- Journal of Hypertension
- Published
- 2009-01
- Volume
- 27
- Issue
- 1
- Pages
- 198-203
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2050350498
- Cited by
- 166
- References
- 27
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 7 · 2023: 5 · 2022: 8 · 2021: 11 · 2020: 8 · 2019: 16 · 2018: 10 · 2017: 9 · 2016: 8 · 2015: 12 · 2014: 7 · 2013: 17 · 2012: 11
- FWCI
- 7.03
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Hypertension (publishedVersion)
- PubMed (publishedVersion)
- BOA (University of Milano-Bicocca) (submittedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Telemedicine and Telehealth Implementation
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- home blood pressure monitoring, remote patient monitoring, hypertension control, ambulatory blood pressure, office blood pressure, quality of life, health care costs, general practice
- MeSH terms
- Aged, Family Practice, Female, Humans, Hypertension, Male, Middle Aged, Telemedicine, Blood Pressure Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review