The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Home blood pressure telemonitoring improves hypertension control in general practice. The TeleBPCare study
Abstract
BACKGROUND: Self blood pressure monitoring at home may improve blood pressure control and patients' compliance with treatment, but its implementation in daily practice faces difficulties. Teletransmission facilities may offer a more efficient approach to long-term home blood pressure monitoring. METHODS: Twelve general practitioners screened 391 consecutive uncontrolled mild-moderate hypertensive patients (80% treated), 329 of whom (58 +/- 11 years, 54% men) were randomized to either usual care on the basis of office blood pressure (group A, n = 113) or to integrated care on the basis of teletransmitted home blood pressure (group B, n = 216). Twenty-four-hour ambulatory blood pressure monitoring was performed at baseline and after 6 months, during which treatment was optimized according to either office (group A) or home (group B) blood pressure values. We compared differences between groups in the rate of daytime ambulatory blood pressure normalization (<130/80 mmHg), need of treatment changes during follow-up, quality of life scores, and healthcare costs. RESULTS: Baseline office blood pressures were 149 +/- 12/89 +/- 9 and 148 +/- 13/89 +/- 7 mmHg in groups A (n = 111) and B (n = 187) respectively, the corresponding daytime values being 140 +/- 11/84 +/- 8 and 139 +/- 11/84 +/- 8 mmHg. The percentage of daytime blood pressure normalization was higher in group B (62%) than in group A (50%) (P < 0.05). There were less frequent treatment changes in group B than in group A (9 vs. 14%, P < 0.05). Quality of life tended to be higher and costs lower in group B. CONCLUSION: Patients' management based on home blood pressure teletransmission led to a better control of ambulatory blood pressure than with usual care, with a more regular treatment regimen.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A smartphone application from the European Society of Hypertension (ESH CARE app) has been validated and continuously updated.”
From São Paulo call to action for the prevention and control of high blood pressure: 2020 (2019) · cites this paper as [65]
Citations
Cites
2013 ESH/ESC Guidelines for the management of arterial hypertension
Authors Task Force Members, Mancia, G., Fagard, R., Narkiewicz, K., Redon, J., Zanchetti, A., Böhm, M., Christiaens, T., Cífková, R., Backer, G. D., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht151 · Cited by 13,739
Self-citationGlobal burden of hypertension: analysis of worldwide data
Kearney, P. M., Whelton, M., Reynolds, K., Muntner, P., Whelton, P. K., & He, J. (2005) · The Lancet · doi:10.1016/s0140-6736(05)17741-1 · Cited by 8,698
2007 Guidelines for the Management of Arterial Hypertension
Mancia, G., Backer, G. D., Dominiczak, A. F., Cífková, R., Fagard, R. H., Germanò, G., Grassi, G. M., Heagerty, A. M., Kjeldsen, S. E., Laurent, S., et al. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e3281fc975a · Cited by 5,870
Self-citationSelected major risk factors and global and regional burden of disease
Ezzati, M., Lopez, A. D., Rodgers, A., Vander Hoorn, S., & Murray, C. J. (2002) · The Lancet · doi:10.1016/s0140-6736(02)11403-6 · Cited by 3,594
Sega, R., Facchetti, R., Bombelli, M., Cesana, G., Corrao, G., Grassi, G., & Mancia, G. (2005) · Circulation · doi:10.1161/01.cir.0000160923.04524.5b · Cited by 1,009
Self-citationBobrie, G. (2004) · JAMA · doi:10.1001/jama.291.11.1342 · Cited by 842
Parati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Self-citationOhkubo, T., Imai, Y., Tsuji, I., Nagai, K., Kato, J., Kikuchi, N., Nishiyama, A., Aihara, A., Sekino, M., Kikuya, M., et al. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816070-00010 · Cited by 746
Blood pressure control by home monitoring: meta-analysis of randomised trials
Cappuccio, F. P., Kerry, S., Forbes, L. J. L., & Donald, A. (2004) · BMJ · doi:10.1136/bmj.38121.684410.ae · Cited by 503
Fagard, R. H., Broeke, C. V. D., & Cort, P. D. (2005) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001903 · Cited by 321
Cited by
Sorted by citations
2013 ESH/ESC Guidelines for the management of arterial hypertension
Authors Task Force Members, Mancia, G., Fagard, R., Narkiewicz, K., Redon, J., Zanchetti, A., Böhm, M., Christiaens, T., Cífková, R., Backer, G. D., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht151 · Cited by 13,739
Self-citationMancia, G., Fagard, R., Narkiewicz, K., Redón, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2013) · Journal of Hypertension · doi:10.1097/01.hjh.0000431740.32696.cc · Cited by 5,655
Self-citationThe Japanese Society of Hypertension Guidelines for the Management of Hypertension (JSH 2019)
Umemura, S., Arima, H., Arima, S., Asayama, K., Dohi, Y., Hirooka, Y., Horio, T., Hoshide, S., Ikeda, S., Ishimitsu, T., et al. (2019) · Hypertension Research · doi:10.1038/s41440-019-0284-9 · Cited by 1,880
Assessment and management of blood-pressure variability
Parati, G., Ochoa, J. E., Lombardi, C., & Bilo, G. (2013) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2013.1 · Cited by 853
Self-citationInteractive telemedicine: effects on professional practice and health care outcomes
Flodgren, G., Rachas, A., Farmer, A. J., Inzitari, M., & Shepperd, S. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd002098.pub2 · Cited by 806
Metadata
- Authors
- Parati, G., Omboni, S., Albini, F., Piantoni, L., Giuliano, A., Revera, M., Illyes, M., & Mancia, G.
- Affiliations
- IRCCS Istituto Auxologico Italiano (IT)
- Italian Institute of Telemedicine (IT)
- Corresponding author
- Parati, Gianfranco
- Venue
- Journal of Hypertension
- Published
- 2009-01
- Volume
- 27
- Issue
- 1
- Pages
- 198-203
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2050350498
- Cited by
- 166
- References
- 27
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 7 · 2023: 5 · 2022: 8 · 2021: 11 · 2020: 8 · 2019: 16 · 2018: 10 · 2017: 9 · 2016: 8 · 2015: 12 · 2014: 7 · 2013: 17 · 2012: 11
- FWCI
- 7.03
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Hypertension (publishedVersion)
- PubMed (publishedVersion)
- BOA (University of Milano-Bicocca) (submittedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Telemedicine and Telehealth Implementation
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- home blood pressure monitoring, remote patient monitoring, hypertension control, ambulatory blood pressure, office blood pressure, quality of life, health care costs, general practice
- MeSH terms
- Aged, Family Practice, Female, Humans, Hypertension, Male, Middle Aged, Telemedicine, Blood Pressure Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review