Poor adherence to home blood pressure measurement schedule
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Consensus dictates that devices used for home blood pressure (BP) measurement should be equipped with a memory to store readings, rather than trusting patients' logbooks. However, data entered in the memory rely on patients' adherence to measurement schedules. We investigated the number and relevance of deviations from the requested measurement schedule. METHODS: We instructed 106 patients to perform 28 BP readings in a 2-week period with a memory-equipped electronic device. Patients were requested to note their scheduled BP values in their logbook and were not informed of the presence of a memory function. RESULTS: The concordance between all BP recordings in both memory and logbook was 90.1% of possible total scheduled readings. The difference in mean BP of all readings from memory compared with all readings from the logbook was -0.06 mmHg (95% confidence interval -0.79 to 0.68) systolic and -0.28 mmHg (95% confidence interval -0.97 to 0.40) diastolic. Unscheduled measurements were performed by 57.5% of patients. Missing scheduled readings in both logbook and memory were found in 34.0% of patients. Fictional data were present for 16.0% of patients. When comparing all individual BP readings from the memory and the logbook, 10.4% of patients were classified in another hypertension stratum according to the European Society of Hypertension criteria. In 23.6% of patients, we did not find any bias. CONCLUSION: In spite of the use of memory-equipped devices, to ensure patients' adherence to measurement schedules, patients still need proper instruction and a close watch.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sega, R., Facchetti, R., Bombelli, M., Cesana, G., Corrao, G., Grassi, G., & Mancia, G. (2005) · Circulation · doi:10.1161/01.cir.0000160923.04524.5b · Cited by 1,009
Bobrie, G. (2004) · JAMA · doi:10.1001/jama.291.11.1342 · Cited by 842
Stergiou, G. S., Baibas, N. M., Gantzarou, A. P., Skeva, I. I., Kalkana, C. B., Roussias, L. G., & Mountokalakis, T. D. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)02324-x · Cited by 268
Reliability of blood glucose monitoring by patients with diabetes mellitus
Mazze, R. S., Shamoon, H., Pasmantier, R., Lucido, D., Murphy, J., Hartmann, K., Kuykendall, V., & Lopatin, W. (1984) · The American Journal of Medicine · doi:10.1016/0002-9343(84)90693-4 · Cited by 261
Home Blood Pressure Measurement
Verberk, W. J., Kroon, A. A., Kessels, A. G. H., & de Leeuw, P. W. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.058 · Cited by 212
Reference Values for Self-recorded Blood Pressure: A Meta-analysis of Summary Data
Thijs, L., Staessen, J. A., Celis, H., de Gaudemaris, R., Imai, Y., Julius, S., & Fagard, R. (1998) · Archives of Internal Medicine · doi:10.1001/archinte.158.5.481 · Cited by 143
Validation of the Stabil-O-Graph blood pressure self-measurement device
Westhoff, T. H., Schmidt, S., Zidek, W., & van der Giet, M. (2008) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1002287 · Cited by 26
Cited by
The Japanese Society of Hypertension Guidelines for the Management of Hypertension (JSH 2019)
Umemura, S., Arima, H., Arima, S., Asayama, K., Dohi, Y., Hirooka, Y., Horio, T., Hoshide, S., Ikeda, S., Ishimitsu, T., et al. (2019) · Hypertension Research · doi:10.1038/s41440-019-0284-9 · Cited by 1,880
as members of the Japanese Society of Hypertension Committee for Guidelines for Self-monitoring of Blood Pressure at Home, Imai, Y., Kario, K., Shimada, K., Kawano, Y., Hasebe, N., Matsuura, H., Tsuchihashi, T., Ohkubo, T., Kuwajima, I., et al. (2012) · Hypertension Research · doi:10.1038/hr.2012.56 · Cited by 203
Omboni, S., & Guarda, A. (2011) · American Journal of Hypertension · doi:10.1038/ajh.2011.100 · Cited by 108
Anstey, D. E., Muntner, P., Bello, N. A., Pugliese, D. N., Yano, Y., Kronish, I. M., Reynolds, K., Schwartz, J. E., & Shimbo, D. (2018) · Hypertension · doi:10.1161/hypertensionaha.118.11319 · Cited by 85
Optimal Schedule for Home Blood Pressure Measurement Based on Prognostic Data: The Finn-Home Study
Niiranen, T. J., Johansson, J. K., Reunanen, A., & Jula, A. M. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.162123 · Cited by 71
Metadata
- Authors
- van der Hoeven, N. V., van den Born, B.-J. H., Cammenga, M., & van Montfrans, G. A.
- Venue
- Journal of Hypertension
- Published
- 2009-02
- Volume
- 27
- Issue
- 2
- Pages
- 275-279
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2139952889
- Cited by
- 40
- References
- 7
- FWCI
- 3.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.