A proposed algorithm for diagnosing hypertension using automated office blood pressure measurement
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To validate an algorithm for the interpretation of automated office blood pressure (AOBP) measurement based upon data from untreated patients referred by physicians in the community for 24-h ambulatory blood pressure monitoring (ABPM). METHODS: An algorithm for interpreting AOBP readings was developed taking into account the previously documented equivalence of AOBP and mean awake ambulatory BP (ABP; mmHg), which were each classified as optimum BP (<130/80), borderline BP (130-139/80-89) and hypertension (>or=140/90). This classification was applied to data derived from 254 untreated patients undergoing 24-h ABPM, AOBP and routine manual BP taken at the patient's own family physician's office. RESULTS: The mean awake ABP (135.3 +/- 12.4/81.0 +/- 10.2) was similar to the mean AOBP (132.6 +/- 17.4/80.0 +/- 11.1) with both values being significantly (P < 0.001) lower than the routine manual BP (149.7 +/- 15.2/89.3 +/- 9.5). Of the 69 patients with a systolic AOBP at least 140, only five (7.3%) exhibited white-coat hypertension with a normal mean awake ambulatory systolic BP less than 130. Similarly, of the 47 patients with a diastolic AOBP at least 90, none had optimum BP (diastolic BP < 80 mmHg on ABPM). White-coat hypertension was significantly (P = 0.005/P = 0.006) more prevalent for systolic/diastolic BP (22.1%/13.4%) when routine, manual BP readings were analysed. CONCLUSION: In contrast to routine manual office BP, a diagnosis of hypertension by AOBP is unlikely to be associated with an optimum awake ABP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
O'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Self-citationFagard, R. H., Celis, H., Thijs, L., Staessen, J. A., Clement, D. L., De Buyzere, M. L., & De Bacquer, D. A. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.100727 · Cited by 742
Diagnostic Thresholds for Ambulatory Blood Pressure Monitoring Based on 10-Year Cardiovascular Risk
Kikuya, M., Hansen, T. W., Thijs, L., Björklund-Bodegård, K., Kuznetsova, T., Ohkubo, T., Richart, T., Torp-Pedersen, C., Lind, L., Ibsen, H., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.662254 · Cited by 314
Cited by
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
“Although fewer data are available, SBP/DBP of 130/80 mm Hg on AOBP is reported to be equivalent to values of awake SBP/ DBP of 130/80 mm Hg on ABPM.(48,50,51) AOBP has also demonstrated a stronger association with subclinical CVD, including intima-media thickness of the carotid artery(58) and left ventricular mass ind…”
MethodInfluentialSelf-citationDaskalopoulou, S. S., Rabi, D. M., Zarnke, K. B., Dasgupta, K., Nerenberg, K., Cloutier, L., Gelfer, M., Lamarre-Cliche, M., Milot, A., Bolli, P., et al. (2015) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2015.02.016 · Cited by 684
Siu, A. L., & on behalf of the U.S. Preventive Services Task Force* (2015) · Annals of Internal Medicine · doi:10.7326/m15-2223 · Cited by 491
Leung, A. A., Nerenberg, K., Daskalopoulou, S. S., McBrien, K., Zarnke, K. B., Dasgupta, K., Cloutier, L., Gelfer, M., Lamarre-Cliche, M., Milot, A., et al. (2016) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2016.02.066 · Cited by 461
Piper, M. A., Evans, C. V., Burda, B. U., Margolis, K. L., O'Connor, E., & Whitlock, E. P. (2015) · Annals of Internal Medicine · doi:10.7326/m14-1539 · Cited by 380
Metadata
- Authors
- Myers, M. G.
- Venue
- Journal of Hypertension
- Published
- 2010-04
- Volume
- 28
- Issue
- 4
- Pages
- 703-708
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W1976591607
- Cited by
- 72
- References
- 5
- FWCI
- 4.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A proposed algorithm for diagnosing hypertension using automated office blood pressure measurement. https://app.cochat.ai/papers/10.1097/hjh.0b013e328335d091
- The paper
- Myers, M. G. (2010). A proposed algorithm for diagnosing hypertension using automated office blood pressure measurement. Journal of Hypertension. https://doi.org/10.1097/hjh.0b013e328335d091
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.