CoChat

Who will bell the cat? A call for a new approach for validating blood pressure measuring devices

O'Brien, Eoin, Stergiou, George · 2010 · Journal of Hypertension
Cited by 10

The DOI matches its Crossref record.

Abstract

Blood pressure (BP) measurement should be the foundation stone on which all decisions in hypertension, be they in practice or in research, are dependent. If BP measurement is inaccurate, it follows that all decisions will be flawed. Yet the history of clinical practice and scientific research is replete with examples of disregard for the accuracy of BP measurement. Recognizing that the commonest measurement in medicine is often inaccurate, clinical scientists and the scientific hypertension organizations have made recommendations over the years to improve the technique of measurement and the accuracy of BP measuring devices. The discipline of validating BP measuring devices has developed from primitive origins with ad-hoc protocols to the latest revision of the European Society of Hypertension International Protocol (ESH International Protocol), which is now available on-line (www.dableducational.org) [1]. In this issue of the Journal Turner [2] asks: ‘ Can we trust automatic sphygmomanometer validations?’ The essence of his case is that, as hypertension is an undisputed leading risk for cardiovascular morbidity and mortality, the devices used to measure BP should be accurate. However, he questions the present policy of trusting the quality control of sphygmomanometer validations to peer review of published reports, which is not without its limitations. He argues that patients, whose health may depend on accurate BP measurements, are surely entitled to expect that the quality control of validation of sphygmomanometers is at least as good as the quality control of the scales used in the sale of potatoes by a greengrocer. Is it not logical then to apply external accreditation of laboratories that validate sphygmomanometers as is done for other measurements that are important to society? It is perhaps timely to review the history of BP device validation before addressing the implications of this reasonable proposal. Humble beginnings with ad-hoc protocols When the technique of BP measurement was introduced into clinical medicine during the early years of the twentieth century, the importance of accuracy and the limitations of the technique were well recognized [3]. However, the standards called for by the clinicians and scientists who pioneered the technique were relaxed as the twentieth century progressed. During the 1960s and 1970s, individual groups, frustrated by the failure of manufacturers to produce evidence to match their often extravagant claims, began to validate BP measuring systems according to a variety of ad-hoc protocols and so illustrated the need for independent validation of devices [4–6]. However well intentioned such protocols may have been, they had the serious disadvantage of not permitting comparison of one device against another because of the differing methodologies of validation [7]. International protocols In 1987, the Association for the Advancement of Medical Instrumentation published a standard for electronic and aneroid sphygmomanometers, which included a protocol for the evaluation of the accuracy of devices [8]. In 1990, the British Hypertension Society (BHS) published a more detailed protocol devoted solely to the validation of devices in the clinical setting [9] and both protocols were revised in 1993 [10,11]. These protocols, which differed in detail, had a common objective, namely the standardization of validation procedures to establish minimum standards of accuracy and performance, and to facilitate comparison of one device with another. A large number of BP measuring devices were evaluated according to one or both protocols, but experience soon demonstrated that the conditions demanded for validation were extremely difficult to fulfill because of the large number of individuals that needed to be recruited and the ranges of BP required. These factors made validation studies difficult to perform and very costly, with the result that fewer centers were prepared to undertake them. In 2002, the Working Group on Blood Pressure Monitoring of the ESH published an updated protocol, named the International Protocol [12]. The ESH Working Group recognized the urgent imperative to provide a simplified protocol that would not sacrifice the integrity of the earlier protocols. The Working Group had the advantage of being able to examine and analyze the data from 19 validation studies performed according to the earlier protocols at the Blood Pressure Unit in Dublin [13]. Critical assessment of this database of evidence permitted rationalization and simplification of validation procedures without losing the merits of the much more complicated earlier protocols. The International Protocol was drafted so as to be applicable to the majority of BP measuring devices on the market. The validation procedure was confined, therefore, to adults over the age of 30 years (as these constitute the majority of individuals with hypertension), and it did not make recommendations for special groups, such a

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/hjh.0b013e32833eafd8

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
O'Brien, E., & Stergiou, G.
Venue
Journal of Hypertension
Published
2010-12
Volume
28
Issue
12
Pages
2378-2381
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2050603206
Cited by
10
References
0
FWCI
0.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.