Effects of breathing frequency on baroreflex effectiveness index and spontaneous baroreflex sensitivity derived by sequence analysis

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Abstract

Aims High-frequency paced breathing is required to avoid overestimation when measuring spectral baroreflex sensitivity (BRSLF) to predict outcomes in cardiovascular patients. We examined whether respiration should also be controlled when measuring the baroreflex effectiveness index (BEI) and baroreflex sensitivity (BRSseq), which are derived by sequence analysis. Methods We studied 17 healthy young adults who breathed spontaneously and controlled their breathing to rates of 0.1, 0.2, 0.3 and 0.4 Hz in the supine position. We found respiratory influences on BEI and BRSseq depended on the lag used to pair the systolic arterial pressure and R-R interval in a sequence. Therefore, the two baroreflex measures were obtained by selecting the lag with a larger number of sequences for each section. Results BEI decreased progressively as the breathing frequency increased. BRSseq remained unchanged at rates of 0.1, 0.2 and 0.3 Hz, but was reduced during 0.4 Hz breathing. In contrast, BRSLF was constant during 0.2, 0.3, and 0.4 Hz breathing, but was greater at 0.1 Hz. Rates of spontaneous breathing range from 0.1 to 0.32 Hz with a mean value of 0.19 Hz. Baroreflex measures obtained for spontaneous breathing were found to be between the values for 0.1 and 0.3 Hz paced breathing. Conclusion BEI and BRSseq do not remain constant at various breathing frequencies. Nonetheless, considering the pattern of change and the frequency range of spontaneous respiration, the authors suggest that high-fr…

Overview

Integrity signals

Registry

Crossref · 10.1097/hjh.0b013e328357ff46

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 2

  1. Hollow, 2011, Can baroreflex measurements with spontaneous sequence analysis be improved by also measuring breathing and by standardization of filtering strategies Physiol M, eas, 32, 1193
  2. Henry, 1998, Interactions between CO2 chemoreflexes and arterial baroreflexes., Am J Physiol, 274, H2177

Cited by

See all 7

Metadata

Authors
Wang, Y.-P., Kuo, T. B. J., Lai, C.-T., Lee, G.-S., & Yang, C. C. H.
Affiliations
Taipei City Hospital (TW)
Corresponding author
Yang, Cheryl C.H.
Venue
Journal of Hypertension
Published
2012-11
Volume
30
Issue
11
Pages
2151-2158
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2317850721
Cited by
7
References
29
Citations by year
2020: 1 · 2017: 1 · 2016: 1 · 2015: 1 · 2013: 3
FWCI
0.82
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Hypertension (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Science Council
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
Keywords
baroreflex sensitivity, respiratory rate, paced breathing, sequence analysis, spontaneous breathing, arterial pressure, RR interval, cardiac autonomic function
MeSH terms
Adult, Cardiovascular Diseases, Female, Heart Rate, Humans, Male, Parasympathetic Nervous System, Prognosis, Respiratory Mechanics, Supine Position, Baroreflex, Young Adult, Respiratory Rate, Biostatistics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.